Sign In | Join Free | My himfr.com
Home > Connectors & Terminals >

ABB CI871AK01 PROFINET IO Master Interface for AC 800M

    Buy cheap ABB CI871AK01 PROFINET IO Master Interface for AC 800M from wholesalers
     
    Buy cheap ABB CI871AK01 PROFINET IO Master Interface for AC 800M from wholesalers
    • Buy cheap ABB CI871AK01 PROFINET IO Master Interface for AC 800M from wholesalers

    ABB CI871AK01 PROFINET IO Master Interface for AC 800M

    Ask Lasest Price
    Brand Name : ABB
    Model Number : CI871AK01
    • Product Details
    • Company Profile

    ABB CI871AK01 PROFINET IO Master Interface for AC 800M

    ABB · CI871AK01

    ABB CI871AK01 PROFINET IO Master Interface for AC 800M

    ABB CI871AK01 PROFINET IO master package with CI871A, TP867 baseplate, one Ethernet channel, module redundancy and hot-swap support.

    TypePROFINET IO master interface kit
    SystemABB AC 800M / System 800xA
    FocusOne-channel PROFINET IO
    BrandABB

    CI871AK01 availability, lead time and order review

    Send RFQ

    Product Introduction

    CI871AK01 is the AC 800M PROFINET IO master kit with CI871A and TP867. It uses one 10/100 Mbit/s channel and supports module redundancy, hot swap and High Integrity controllers.

    Engineering note: Use TP867 CH1 for PROFINET IO; ABB does not specify CH2 as a second PROFINET path.

    Technical Specifications

    Select a category to view its specifications. All categories are closed by default.

    Identification & functionView 7 specificationsHide specifications
    ABB article number3BSE092693R1
    Package contentsCI871A communication interface + TP867 baseplate, 60 mm wide
    24 V consumption160 mA typical
    Pollution degreeDegree 2 to IEC/EN 61131-2
    Electrical safetyUL 61010-1 and UL 61010-2-201
    Hazardous locationUL 60079-15; cULus Class 1 Zone 2, AEx nA IIC T4, Ex nA IIC T4 Gc X
    RoHS / WEEEEU, UAE and China RoHS; WEEE Directive 2012/19/EU
    Interface & performanceView 5 specificationsHide specifications
    Protocol / rolePROFINET IO master
    Number of channels1
    Transmission speed10/100 Mbit/s
    Active PROFINET portTP867 CH1; connected through an Ethernet switch
    ConnectorRJ45 female, 8-pin
    Integration & diagnosticsView 5 specificationsHide specifications
    Line redundancyNo
    Module redundancyYes
    Hot swapYes
    High Integrity controller useYes
    Max units on CEX-Bus12
    Power, environment & sizeView 7 specificationsHide specifications
    Operating / storage temperature0 to +55 °C / −40 to +70 °C
    Altitude2,000 m to IEC/EN 61131-2
    Humidity5–95%, non-condensing
    Corrosion protectionG3 to ISA 71.04
    Protection classIP20 to EN 60529 / IEC 529
    Marine certificatesDNV-GL; ABS, BV and LR shown as pending in the cited selector
    Dimensions / weight59 × 185 × 127.5 mm; 700 g including base

    Compatibility & Replacement

    Required software. ABB states that the module works with System 800xA 6.0.3.3, 6.1.1 and subsequent versions. The Compact Product Suite catalog also states Compact Control Builder 6.0.0-3, 6.1.1 and later.

    Network fit. The package is for AC 800M PROFINET IO master service. The PROFINET network connects through an Ethernet switch, using CH1 on the TP867 baseplate.

    Replacement scope. No direct substitute or historical replacement relationship is stated in the cited ABB selector for this exact package. Match article number, system release and engineered redundancy rather than selecting by connector appearance.

    Applications & Fault Scenarios

    01

    PROFINET IO device integration

    Provides the controller-side master interface for supported PROFINET IO devices on an Ethernet network.

    02

    Redundant communication module design

    ABB supports module redundancy, but not line redundancy. Confirm how the project handles primary/secondary modules and the upstream network.

    03

    Device not reachable

    Check that the cable is on CH1, the Ethernet switch path is active and the project’s device name/IP configuration matches the commissioned node.

    04

    Wrong-port commissioning error

    TP867 exposes two RJ45 connectors, yet only CH1 is used for PROFINET IO. A cable on CH2 will not create the intended connection.

    05

    Version-related startup failure

    If hardware is recognized incorrectly or cannot be configured, compare the actual 800xA/Control Builder baseline with ABB’s stated minimum versions.

    AMIKON SUPPORT

    Independent spare-parts support

    Amikon can review the part number, installed system, quantity, destination and required date before quotation, helping maintenance teams avoid incomplete purchase requests.

    Pre-outage checkpoints

    • Verify System 800xA or Compact Control Builder release.
    • Record PROFINET device names, IP plan and switch port mapping.
    • Confirm cable placement on TP867 CH1.
    • For redundant modules, capture primary/secondary status and validate the switchover procedure.

    Amikon Supply & Service

    Independent multi-brand support for maintenance, outage and legacy-system requirements.

    Amikon engineer checking an industrial control cabinet
    System and wiring checks.
    Amikon service team in the automation warehouse
    Spare-parts and after-sales support.
    Order reviewPart number, quantity, destination and required date checked.
    Inspection & testingLabel, condition and serial checks; testing when agreed.
    Packing & dispatchProtective export packing and delivery coordination.
    DOA, returns & warrantyPrompt issue review under quoted return and warranty terms.

    Request for Quotation

    • Part Number
    • Quantity
    • Destination
    • Required Date
    • Machine / System Model
    Direct RFQ contactMiya ZhengIndustrial automation spare-parts support
    WhatsApp+86 180 2077 6792

    Multi-brand Spare Parts Also Requested

    • 6639363D1
    • LR36536
    • NTAI06PS083K
    • FDNL-L1600-T
    • GE IC600CB536L
    • 1053-71-1975-03
    • 1037589
    • 1151DP3J12B2
    • 6L-L45-F1A-RR
    • 6L-E4-C1A-RR
    • 449D701G07
    • CU13S-11
    • SAT-101BX
    • 593CM-BOV16
    • 810-E440582/2
    • CB273 42185-800-01
    • BF100F 65A974G01
    • 9125DAV
    • 1955565-E
    • 6EC1660-3A
    • CLV440-0010
    • 809-112
    • MSQB30R MHZL2-25D
    • DU321
    • CSC4T
    • D4BL-K3
    • TS500R
    • F39-A01POG-D
    • VS5M-1A-GBT-68-GD
    • MJB-00-801 MJB-IN-V1.0

    These models are listed only as independent sourcing references. They are not substitutes for CI871AK01. Compatibility, configuration and stock must be confirmed separately for each item.

    CI871AK01 FAQ

    Is ABB CI871AK01 a PROFINET IO master or slave?
    ABB identifies the interface as a PROFINET IO master.
    Which TP867 Ethernet port is used by ABB CI871AK01?
    Use CH1. ABB states that only the 100 Mbit/s-capable CH1 connector is used for PROFINET IO.
    Does ABB CI871AK01 support line redundancy?
    No. The official selector records line redundancy as No and module redundancy as Yes.
    Can ABB CI871AK01 be hot-swapped?
    Yes, subject to the site’s approved maintenance procedure and the engineered module configuration.
    Which software versions support ABB CI871AK01?
    ABB specifies System 800xA 6.0.3.3, 6.1.1 and later; Compact Control Builder 6.0.0-3, 6.1.1 and later is also listed.
    What should an ABB CI871AK01 RFQ include?
    Send part number, quantity, destination, required date, controller/system model, software release and whether module redundancy is configured.
    Quality ABB CI871AK01 PROFINET IO Master Interface for AC 800M for sale
    Company Info.
    AMIKON LIMITED
    Verified Supplier
    View Contact Details
    Product List
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: AMIKON LIMITED
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more ABB PLC products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0