    ABB Bailey NTCL01 Communication Termination Unit

    Ask Lasest Price
    Model Number : NTCL01
    Brand Name : ABB
    • Product Details
    • Company Profile

    ABB Bailey NTCL01 Communication Termination Unit

    NTCL01 · ABB / Bailey

    Twinax or coax network termination

    ABB Bailey NTCL01 Communication Termination Unit

    ABB Bailey NTCL01 communication termination unit for documented twinax or coax INFI-NET, Plant Loop and Symphony Plus Cnet connections.

    TypeCommunication termination unit
    SystemINFI-NET / Plant Loop / Symphony Plus Cnet
    FocusTwinax or coax network termination
    BrandABB / Bailey
    01

    Overview

    Product Introduction

    NTCL01 terminates an ABB Bailey communication network connection at the network interface. The legacy instruction covers INNIS01 and INLIM03 applications on INFI-NET or Plant Loop, while the current Symphony Plus catalog identifies NTCL01 for Cnet termination to SPNIS.

    Cable medium and termination impedance are configured by jumpers. Because the jumper map changes with board revision, the silkscreen revision and applicable instruction table must be checked before the unit is placed on a live communication segment.

    02

    Verified manufacturer data

    Technical Specifications

    Network mediaTwinaxial or coaxial cable
    Legacy interfaces documentedINNIS01 Network Interface Slave; INLIM03 Loop Interface Module
    Current catalog contextCnet termination to SPNIS
    MountingOne position on NFTP01 Field Termination Panel
    Operating power+24 VDC
    Current consumption15.8 mA typical; 19.7 mA maximum
    On-board fuse1 A / 250 V
    Configuration methodRevision-dependent jumpers for cable type and termination impedance
    Operating temperature0 to 70 °C (32 to 158 °F)
    Relative humidity5–90% ±5% to 55 °C; 5–40% ±5% at 70 °C, noncondensing
    AltitudeSea level to 3 km (1.86 mi)
    AtmosphereNoncorrosive
    Legacy certification statedCSA certified for ordinary (nonhazardous) locations
    03

    System fit

    Compatibility & Network Generations

    01

    The manufacturer instruction documents NTCL01 with INNIS01 and INLIM03 on INFI-NET and Plant Loop installations.

    02

    The current ABB catalog identifies the same part number as the Cnet communication termination unit for SPNIS and states support for twinax or coax.

    03

    These are documented system generations, not a claim that one interface module is a direct replacement for another. Confirm the installed network, interface module, cable kit and board revision.

    04

    Maintenance context

    Applications & Fault Scenarios

    Intermittent node communication

    A network node repeatedly enters and leaves the loop, prompting checks of connectors, cable shields and the local termination setting.

    Media mismatch

    A spare arrives configured for coax while the cabinet segment uses twinax, or the cable adapter set differs from the site drawing.

    Revision-dependent setup

    The installed board and replacement carry different silkscreen revisions, so copied jumper positions may be unsafe.

    Network extension work

    A planned Cnet, INFI-NET or Plant Loop change requires the correct ABB cable assembly and end-of-segment termination.

    05

    Field practice

    Network Cabling & Jumper Control

    Identify the board revision

    Use the revision marking to select the manufacturer jumper table. The instruction distinguishes earlier A–C artwork from later D/E and F-or-later boards.

    Match the cable system

    Legacy documented assemblies include NKPL01/02 twinax, NKCL01/02 coax, NKTT01 termination-to-termination and specified NKLS interface cables. Confirm the installed drawing rather than substituting by connector appearance.

    Maintain shield continuity

    Inspect cable screens, connector bodies and cabinet bonding. Poor shield or connector condition can resemble an interface-module failure.

    Control the outage

    Changing termination on an operating network can affect more than one node. Isolate the work, record jumper positions and confirm stable communications after restoration.

    06

    Source record

    Official Documentation

    ManufacturerDocumentDocument no. / versionLink
    Elsag BaileyCommunication Termination Unit (NTCL01) Instruction (manufacturer-issued; archived copy)I-E96-422AOpen document
    ABBABB Ability™ Symphony® Plus Product Catalog2VAA005340 en GOpen document
    07

    Order support

    Amikon Service

    Test scope and unit condition are confirmed before dispatch, with ESD-safe export packing. DOA, returns, warranty and after-sales support follow the quotation.

    08

    Product-specific answers

    FAQ

    Does NTCL01 support both twinax and coax network cable?

    Yes. Both media are documented, but the cable assemblies and jumper configuration must match the installed network and board revision.

    Which interface modules are documented with NTCL01?

    The legacy instruction covers INNIS01 and INLIM03. The current ABB catalog lists Cnet termination to SPNIS.

    Why must the NTCL01 board revision be checked before setting jumpers?

    The manufacturer uses different jumper maps for different board artwork revisions. Copying physical positions from another revision can produce the wrong cable or impedance selection.

    Can NTCL01 be replaced while the communication loop remains in service?

    Plan the work as a network intervention. Removing cabling or changing termination can disturb multiple nodes, so follow the site outage and ABB service procedure.

    What should be inspected during an NTCL01 communication fault?

    Check the +24 V supply and fuse, connectors, cable shield and continuity, media selection, termination setting and the adjacent interface module diagnostics.

    What should an NTCL01 purchase request identify?

    Include the full part number and board revision, cable medium, interface module, quantity, destination, required date and installed system model.

    Request a quotation

    NTCL01 RFQ

    For an accurate offer and revision check, send the following five details. Add nameplate photographs and connected-module information when available.

    Email the RFQ
    • Part Number
    • Quantity
    • Destination
    • Required Date
    • Machine/System Model
    Quality ABB Bailey NTCL01 Communication Termination Unit for sale
    Company Info.
    AMIKON LIMITED
    Verified Supplier
    View Contact Details
    Product List
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: AMIKON LIMITED
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more ABB PLC products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0