Sign In | Join Free | My himfr.com
Home > Transfer Film >

Seeing Deeper: Understanding ST830E's Roll-Off Performance and 2.4mm Imaging Depth

    Buy cheap Seeing Deeper: Understanding ST830E's Roll-Off Performance and 2.4mm Imaging Depth from wholesalers
     
    Buy cheap Seeing Deeper: Understanding ST830E's Roll-Off Performance and 2.4mm Imaging Depth from wholesalers
    • Buy cheap Seeing Deeper: Understanding ST830E's Roll-Off Performance and 2.4mm Imaging Depth from wholesalers
    • Buy cheap Seeing Deeper: Understanding ST830E's Roll-Off Performance and 2.4mm Imaging Depth from wholesalers
    • Buy cheap Seeing Deeper: Understanding ST830E's Roll-Off Performance and 2.4mm Imaging Depth from wholesalers

    Seeing Deeper: Understanding ST830E's Roll-Off Performance and 2.4mm Imaging Depth

    Ask Lasest Price
    Supply Ability : 100PCS per 40-60 working days
    Model Number : ST830E
    Delivery Time : 40-60 WORKING DAYS
    Payment Terms : T/T,Western Union
    Price : USD20600 - USD28600
    Certification : ISO9001
    Brand Name : JINSP
    • Product Details
    • Company Profile

    Seeing Deeper: Understanding ST830E's Roll-Off Performance and 2.4mm Imaging Depth

    Seeing Deeper: Understanding ST830E's Roll-Off Performance and 2.4mm Imaging Depth

    Imaging depth is a fundamental limitation in optical coherence tomography, determining how far into a sample the system can visualize before signal attenuation renders images unusable. The JINSP ST830E OCT spectrometer addresses this challenge with exceptional roll-off performance that maintains signal quality even at the maximum 2.4mm imaging depth.


    Roll-off, or SNR fall-off, refers to the progressive attenuation of signal with increasing imaging depth in SD-OCT systems. As light penetrates deeper into tissue or material, scattering and absorption reduce the return signal strength. Additionally, the spectrometer's optical and electronic characteristics introduce depth-dependent signal loss. The rate at which signal decays with depth—the roll-off characteristic—directly determines the practical imaging depth of the system.


    The ST830E achieves superior roll-off performance through several design optimizations. The high-efficiency VPH grating ensures that maximum light is diffracted to the detector at all wavelengths, maintaining signal strength across the full spectral range. The 2048-pixel CMOS detector with 10×200μm pixel size provides uniform sensitivity across the sensing area. The hardware wavenumber-linear design eliminates the phase noise that can be introduced by software resampling, preserving signal integrity at depth.


    The practical significance of excellent roll-off performance is substantial. In ophthalmic OCT, superior roll-off enables visualization of the choroid—the vascular layer beneath the retina that is critical for diagnosing age-related macular degeneration and other retinal diseases. The ST830E's 2.4mm imaging depth, combined with outstanding roll-off characteristics, allows clinicians to assess choroidal thickness and structure with confidence.


    In dermatological applications, deep imaging enables visualization of the full dermal layer, including the dermal-epidermal junction and the superficial vascular networks. This capability supports research into skin aging, inflammatory conditions, and wound healing. The ST830E's deep imaging capability, combined with high resolution, provides researchers with a comprehensive view of skin structure and pathology.

    In industrial inspection, deep imaging allows nondestructive evaluation of thicker samples. The ST830E's 2.4mm imaging depth is sufficient for inspecting many coatings, composites, and manufactured components. For applications requiring even greater depth, the ST850E variant offers 7mm imaging depth.


    The ST830E's excellent roll-off performance is closely tied to its other performance attributes. The 110dB SNR ensures that signals returning from depth are still well above the noise floor. The high line scan rate—up to 250kHz—enables averaging of multiple A-scans to further improve SNR at depth without sacrificing overall acquisition speed. The stable, mature design ensures that roll-off performance is maintained consistently over time.


    For researchers, clinicians, and industrial users requiring deep imaging capability, the ST830E's combination of 2.4mm imaging depth, exceptional roll-off performance, and high SNR provides the foundation for high-quality imaging across the full depth range. The customizable wavelength range allows optimization for specific penetration requirements, ensuring that the spectrometer delivers optimal performance for each application.


    Technical Parameters:

    Model No.ST830E
    DetectorTypeCMOS
    Optical parametersEffective pixels2048pixels
    Cell size10*200um
    Photosensitive area20.52*0.2mm
    Maximum line sweep speed130kHz or 250kHz
    Wavelength range790nm-910nm
    Optical resolution0.07nm
    Imaging depth2.4mm
    Optical designVPH raster & wave ridge linear design
    Focal length100mm
    Incident optical interfaceFC/APC fibre optic interface
    Electrical parametersData output interfaceUSB3.0 (max. 130kHz) or
    Camera Link (max. 250kHz)
    ADC bit depth12 Bit
    Power supplyDC 6V to 15V
    Operating current<600mA
    Operating temperature0°C~50°C
    Storage temperature'-20°C~60°C
    Operating humidity< 90% RH (non-condensing)
    Physical parametersSize260*180*80mm
    Weight1.5kg

    Company Introduction:

    JINSP Company Limited has won the National Science and Technology Commission's Scientific and Technological Achievement Appraisal Certificate and the China Patent Excellence Award, and related products have been obtained has won authoritative awards such as the Geneva International Invention Award, the Beijing New Technology and New Product Certificate, and the "Innovation Achievement Award" of the Zhu Liangyi Analytical Instrument Innovation Award.JINSP is a professional leading solution provider of molecular spectroscopy, particulaly in Roman Spectroscopy for many years.


    Our products mostly include:
    --OCT spectrometers;
    --Desktop/portable, online Raman analyzers for laboratory or indutrial liquid & gas analysis;
    --On-site rapid detectors/identifiers based on Raman technology for drugs, liquid, food safety, explosive & hazardous materials, pharmaceutical industry etc;

    FAQ:

    Q1: What is the brand name of this OCT Spectrometer?

    A1: The brand name of this OCT Spectrometer is JINSP.

    Q2: What is the model number of this OCT Spectrometer?

    A2: The model number of this OCT Spectrometer is ST830E.

    Q3: Where is this OCT Spectrometer made?

    A3: This OCT Spectrometer is made in China.

    Q4: What are the payment terms for this OCT Spectrometer?

    A4: The payment terms for this OCT Spectrometer are T/T and Western Union.

    Quality Seeing Deeper: Understanding ST830E's Roll-Off Performance and 2.4mm Imaging Depth for sale
    Company Info.
    JINSP Company Ltd.
    Verified Supplier
    View Contact Details
    Product List
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: JINSP Company Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more OCT Spectrometer products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0