Sign In | Join Free | My himfr.com
Home > Electronic Measuring Instruments >

SS304 Sanitary Electromagnetic Type Flow Meter DN15-DN2000 For Beverage Industries

    Buy cheap SS304 Sanitary Electromagnetic Type Flow Meter DN15-DN2000 For Beverage Industries from wholesalers
     
    Buy cheap SS304 Sanitary Electromagnetic Type Flow Meter DN15-DN2000 For Beverage Industries from wholesalers
    • Buy cheap SS304 Sanitary Electromagnetic Type Flow Meter DN15-DN2000 For Beverage Industries from wholesalers
    • Buy cheap SS304 Sanitary Electromagnetic Type Flow Meter DN15-DN2000 For Beverage Industries from wholesalers
    • Buy cheap SS304 Sanitary Electromagnetic Type Flow Meter DN15-DN2000 For Beverage Industries from wholesalers
    • Buy cheap SS304 Sanitary Electromagnetic Type Flow Meter DN15-DN2000 For Beverage Industries from wholesalers

    SS304 Sanitary Electromagnetic Type Flow Meter DN15-DN2000 For Beverage Industries

    Ask Lasest Price
    Brand Name :
    Model Number : MLF
    Price : Negotiation
    Payment Terms : T/T
    Supply Ability : 500pcs per month
    Delivery Time : 7-10 working days
    • Product Details
    • Company Profile

    SS304 Sanitary Electromagnetic Type Flow Meter DN15-DN2000 For Beverage Industries

    SS304 Sanitary Electromagnetic Flow Meter for Beverage Industries DN15-DN2000


    1. Introduction

    MLF electromagnetic flow meter, composed of sensor and converter, works based on Faraday’s law of electromagnetic induction law. It is used to measure electrical conductivity of liquid or solid. Generally, the electrical conductivity should be over 5υS/cm(electrical conductivity of tap water, raw water is about 100~500υS/cm),It can also be used to measure various media like acid, alkali, saline solution, paper pulp or pulp and so on. But these media can’t contain a lot of magnetic materials and bubbles.

    MLF electromagnetic flow meter is a kind of instrument which is used for measuring the flow conductivity liquid. The meter is widely used in flow measuring of Metallurgy, Chemical Industry, Paper Industry,Environmental Protection, Oil Industry, Textile Industry, Food Industry and City Administration, Water Works,etc.


    2. Features

    MLF electromagnetic Flowmeter is explosion-proof design.

    function of low conductivity measurement.

    There are 9 language options to meet the needs of different customers.

    Have self-regulation function and self-examination.

    Different outputs are optional: hart, RS485 Profibus ,4-20 mA, frequency, pulse.


    3. Specification

    MLF TypeDivided TypeIntegrated TypeExplosive Proof Integrated TypeBattery Powered TypeHeat Energy Type
    Accuracy±0.2% or ±0.5%
    Pipeline DiameterDN10-DN2000DN10-DN600DN25-DN2000
    FlangeGB, ANSI, JIS, BS, Others
    PressureDN10-DN600 1.0 1.6 2.5 4.0MPa
    DN700-DN2000 0.6 1.0 1.6MPa
    Liner MaterialCR, PTFE, PU, Hard Rubber, PFA, FEP(F46)
    Conductivity≥5µs/cm(Please contact us if it is less than 5µs/cm)
    Electrode316L SS, Hb, Ta, Ti, Hc, Tungsten Carbide, Others
    Protection ClassIP65, IP66, IP67, IP68
    Medium Temperature-25~180
    (Please refer to liner material)
    -25~80(Please refer to liner material)-25~180
    (Please refer to liner material)
    Ambient Temperature for Accuracy Influence<±0.1%/10 or <±0.25%/10 at the ambient temperature of -25~60
    Repetability≤±0.1% or ±0.25%
    Analog Output Error≤±0.02mA
    Velocity0.3~10m/s
    Electrical connectionM20x1.5 Seal Cartridge, GB1/2, NPT1/2
    Output4-20mA, Pulse, RS485, Hart, Profibus

    4. Selection of Liner Material

    Liner MaterialMain PerformanceApplication
    PTFE

    1. Have the most stable chemical properties in plastic and resistance to boiling hydrochlor and sulfuric acid, nitric acid aqua regia, strong alkali, and all kinds of organic solvents, but can not resist the corrosion of chlorine trifluoride, high temperature nitrogen trifluoride, liquid fluorine, liquid oxygen and ozone.

    2. Low abrasion resistance.

    3. Low negative pressure resistance

    1. -25~140℃

    2. Strong corrosion medium, like strong acid and alkali

    3. Healthcare medium

    CROil proof, solvent resistance, oxidatite resistance and the resistance to the erosion of common medium like acid, alkali, salt, etc.

    1. <80℃

    2. Be able to measure sewage and mud

    PU

    1. Very good abrasive resistance, flexibility.

    2. Low acid and alkali resistance.

    1. <65℃

    2. Neutral strong abrasion resistance medium

    Hard Rubber

    1. Good resistance to room temperature, hydrochloric acid, acetic acid, oxalic acid, ammonia, phosphoric acid and 50% sulfuric acid, sodium hydroxide, potassium hydroxide

    2. Avoid strong oxidants

    1. <80℃

    2. General acid, alkali, salt solution

    PFA

    1. Can be used for most corrosive medium like acides, alkalis, and strong oxidant.

    2. High material strength, resistance to aging, better than PTFE, EFP in high temperature

    3. Injection molding for higher negative pressure

    1. 40~180℃

    2. Strong corrosion medium, like strong acid and alkali

    3. Healthcare mdium

    FEP(F46)

    1. Hydrophobicity and non-viscous

    2. Corrosion resistance is inferior to PFA

    3. Negative pressure

    1. 40~180℃

    2. Strong corrosion medium, like strong acid and alkali

    3. Healthcare mdium


    5. Selection of Electrode Materials

    Electrode MaterialMain Performance
    316LGood resistance to the corrosion of nitric acid, <5% sulfuric acid under room temperature, acetic acid, alkaline fluid, sulfite under certain pressure, seawater and scetic acid, etc. It can be widely used in petrochemical urea, vinylon.
    Hb

    Good resistance to the all the concentration of hydrochloric acid below the boiling point, also resistance tothe corrosion of non-oxidizing acid, alkali, salt like sulfuric acid phosphoric acid hydrofluoric acid, organic acids.

    HcResistance to the corrosion of oxidizing acids like metric acid, mixed acid. The mixture of chromium acid and sulfuric acid, and salts of oxidative, like Fe3+, Q3+, and some other oxidants, like hypochlorite salt solution higher than normal tmperature and seawater.
    TiResistance the corrosion of seawater, various chlorides, hypochlorite, oxidizing acid(including fuming nitric acid), and organic acid or alkali, but don't be resistance to the corrosion of pure reducint acid(like sulfuric acid, hydrochloric acid). But if acid includes oxidants(like nitric acid, Fe3+, Q3+), the corrosion resistance will decrease.
    TaGood corrosion resistance similar to glass. Resistance to the corrosion of chemical medium(including hydrochloric acid and fumiing sulfuric acid), but can not be used for sodium hydromide fluid.
    Pt-IrHave good corrosion resistance of all acid, and can be resistance to the corrosion of alkali, all salt except aqua regia, ammonium slat and few other medium
    Tungsten CarbideFor pulp and sewage, good resistance to solid particle interference.

    6.Instrument Detection & Maintenance


    Electromagnetic flowmeter has self-diagnosis function. In addition to power supply and hardware circuit faults, the system also alarms other faults in general use. These messages give corresponding tips in the lower right corner of the screen.


    1 Maintenance and repair

    A) the sensor installation site shall meet the requirements of section 4, and please keep the housing clean and tidy;

    B) The transmitter shall be placed in a clean, ventilated and dry place;

    C) it needs to be checked every two years. for high-precision users, the instrument needs to be submitted for review.


    2 Transportation and storage

    A) the instrument must be packed before transportation and handled with care.

    B) The storage place must be dry and ventilated to avoid corrosive gas erosion, and the ambient temperature should not be too low or too high;

    C) the storage time should not exceed three years.


    3. Unpacking inspection

    A) the package cannot be opened with a heavy hammer, so be careful not to damage the instrument.

    B) carefully check the contents according to the packing list.


    Quality SS304 Sanitary Electromagnetic Type Flow Meter DN15-DN2000 For Beverage Industries for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Industrial Flow Meter products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0