Sign In | Join Free | My himfr.com
Home > Measuring & Gauging Tools >

Remote Type Liquid Electronic Magnetic Flow Meter With RS485 / Hart

    Buy cheap Remote Type Liquid Electronic Magnetic Flow Meter With RS485 / Hart from wholesalers
     
    Buy cheap Remote Type Liquid Electronic Magnetic Flow Meter With RS485 / Hart from wholesalers
    • Buy cheap Remote Type Liquid Electronic Magnetic Flow Meter With RS485 / Hart from wholesalers
    • Buy cheap Remote Type Liquid Electronic Magnetic Flow Meter With RS485 / Hart from wholesalers

    Remote Type Liquid Electronic Magnetic Flow Meter With RS485 / Hart

    Ask Lasest Price
    Brand Name :
    Model Number : MLF
    Price : Negotiation
    Payment Terms : T/T
    Supply Ability : 500pcs per month
    Delivery Time : 7-10 working days
    • Product Details
    • Company Profile

    Remote Type Liquid Electronic Magnetic Flow Meter With RS485 / Hart

    Remote Type Liquid Electronic Magnetic Flow Meter With RS485 / Hart


    1. Introduction

    The MLF electromagnetic flowmeter works according to Faraday's law of electromagnetic induction and consists of a sensor and a converter. Used to measure the conductivity of liquids or solids. Under normal circumstances, its conductivity should be greater than 5μS/cm (the conductivity of tap water and raw water is about 100-500μS/cm), and it can also be used to measure acids, alkali, brine, pulp or pulp and other media. But these media cannot contain a lot of magnetic substances and bubbles.

    MLF electromagnetic flowmeter is an instrument for measuring liquid fluidity. It is widely used in flow measurement in metallurgy, chemical industry, paper making, environmental protection, petroleum, textile, food, urban management, water plant and other industries.


    2. Features
    The MLF electromagnetic flow meter is for explosive proof design.
    It has the function of low conductivity measurement.
    It has Chinese, English, Korean, Polish, Turkish, French and Portuguese languages languages for option to satisfy different customers’ requirements.
    It has the function of self-adjustment and self-checking.
    A variety of outputs are optional:Hart, RS485, Profibus, 4-20mA, Frequency, Pulse.


    3. Specification

    MLF TypeDivided TypeIntegrated TypeExplosive Proof Integrated TypeBattery Powered TypeHeat Energy Type
    Accuracy±0.2% or ±0.5%
    Pipeline DiameterDN10-DN2000DN10-DN600DN25-DN2000
    FlangeGB, ANSI, JIS, BS, Others
    PressureDN10-DN600 1.0 1.6 2.5 4.0MPa
    DN700-DN2000 0.6 1.0 1.6MPa
    Liner MaterialCR, PTFE, PU, Hard Rubber, PFA, FEP(F46)
    Conductivity≥5µs/cm(Please contact us if it is less than 5µs/cm)
    Electrode316L SS, Hb, Ta, Ti, Hc, Tungsten Carbide, Others
    Protection ClassIP65, IP66, IP67, IP68
    Medium Temperature-25~180
    (Please refer to liner material)
    -25~80(Please refer to liner material)-25~180
    (Please refer to liner material)
    Ambient Temperature for Accuracy Influence<±0.1%/10 or <±0.25%/10 at the ambient temperature of -25~60
    Repetability≤±0.1% or ±0.25%
    Analog Output Error≤±0.02mA
    Velocity0.3~10m/s
    Electrical connectionM20x1.5 Seal Cartridge, GB1/2, NPT1/2
    Output4-20mA, Pulse, RS485, Hart, Profibus

    4. Selection of Liner Material

    Liner MaterialMain PerformanceApplication
    PTFE

    1 It has the most stable chemical properties in plastics, resistant to boiling hydrogen chloride and sulfuric acid, nitric acid, aqua regia, strong alkali and various organic solvents, but not resistant to chlorine trifluoride, high temperature nitrogen trifluoride, liquid fluorine, and liquid oxygen And ozone corrosion.

    2 Low wear resistance.

    3 Low negative pressure resistance.

    1. -25~140℃

    2. Strong corrosion medium, like strong acid and alkali

    3. Healthcare medium

    CROil proof, solvent resistance, oxidatite resistance and the resistance to the erosion of common medium like acid, alkali, salt, etc.

    1. <80℃

    2. Be able to measure sewage and mud

    PU

    1. Very good abrasive resistance, flexibility.

    2. Low acid and alkali resistance.

    1. <65℃

    2. Neutral strong abrasion resistance medium

    Hard Rubber

    1 Room temperature resistance, hydrochloric acid, acetic acid, oxalic acid, ammonia, phosphoric acid and 50% sulfuric acid, sodium hydroxide, potassium hydroxide

    2 Avoid strong oxidants

    1. <80℃

    2. General acid, alkali, salt solution

    PFA

    1. Can be used for most corrosive medium like acides, alkalis, and strong oxidant.

    2. High material strength, resistance to aging, better than PTFE, EFP in high temperature

    3. Injection molding for higher negative pressure

    1. 40~180℃

    2. Strong corrosion medium, like strong acid and alkali

    3. Healthcare mdium

    FEP(F46)

    1. Hydrophobicity and non-viscous

    2. Corrosion resistance is inferior to PFA

    3. Negative pressure

    1. 40~180℃

    2. Strong corrosion medium, like strong acid and alkali

    3. Healthcare mdium


    5. Dimensional Sketches

    a. Dimension of Converter

    Divided Type


    b. Dimension of Sensor



    Pipeline DiameterDimension
    LWH
    1516095130
    20160105137
    25160115150
    32160135160
    40200145175
    50200160185
    65200180205
    80200195215
    100250215235
    125250245275
    150300280300
    200350335355
    250400400405
    300500455460
    350500515520
    400600575580
    450600635630
    500600710685
    600600835795
    700700905910
    80080010201030
    90090011201120
    1000100012451250
    1200120014651470

    6. Configuration

    MLF Series Electromagnetic Flow Meter Configuration
    ModelMLF
    Sensor InstallationSFlange Type Sensor
    CInsertion Type Sensor
    OOthers
    Pipeline Diameter1010mm
    1515mm
    2020mm
    ......
    20002000mm
    Electrode InstallationFStandard Fixed Type
    Electrode MaterialA316L SS
    BHb
    CTa
    DTi
    EHc
    FTungsten Carbide
    GOthers
    Liner MaterialRRubber
    PPTFE
    OOthers
    Pipe MaterialB304 SS (Standard)
    C316 SS
    Flange TypeGGB (Standard)
    AANSI
    JJIS
    BBS
    OOthers
    Flange MaterialA304 SS
    B316 SS
    C#20 Carbon Steel (Standard)
    Cover MaterialD304 SS
    E316 SS
    FCarbon Steel+ Epoxy Metallic Paint (Standard)
    Matching Flange0Without Matching Flange (Standard)
    1With Matching Flange
    Ground Ring0Without Ground Ring (Standard)
    1With Ground Ring
    Rated Pressure101.0MPa
    161.6MPa
    252.5MPa
    404.0MPa
    Working TemperatureE≤60℃
    H≤180℃(Divided Type)
    TypeIIntegrated Type
    DDivided Type
    OutputPPulse
    A4-20mA
    GRS485
    HHart
    QOthers
    Power Supply0220VAC
    124VDC
    2Battery-powered
    Protection Class0IP65 (Integrated/Divided Type)
    1IP67 (Divided Type)
    2IP68 (Divided Type)
    Other FeaturesRHeat Energy Function
    PWith PT1000
    BWithout PT1000
    Explosion Proof0None
    EXExplosive Proof

    7. Instrument Detection & Maintenance


    The electromagnetic flowmeter has a self-diagnostic function. In addition to power supply and hardware circuit failures, the system also alarms other failures in general use. These messages will give corresponding prompts in the lower right corner of the screen.


    1 Maintenance and repair

    a) The sensor installation site should meet the requirements of Section 4, please keep the housing tidy;

    b) The transmitter should be placed in a clean, ventilated and dry place;

    c) It needs to be inspected every two years. For high-precision users, the instrument needs to be submitted for review.


    2 Transportation and storage

    a) The instrument must be packaged before transportation, and be handled with care when loading and unloading.

    b) The storage place must be dry and ventilated to avoid corrosive gases, and the ambient temperature should not be too low or too high;

    c) The storage time should not exceed three years.


    3. Unpacking inspection

    a) The package cannot be opened with a heavy hammer, be careful not to damage the instrument

    b) Check the contents carefully according to the packing list.


    Quality Remote Type Liquid Electronic Magnetic Flow Meter With RS485 / Hart for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Industrial Flow Meter products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0