    TD1880 High-Precision Multi-Product Calibrator

    Introduction

    • TD1880, a wide-range, multi-value and high-precision calibrator, can accurately output ultra-precision AC/DC voltage, current, phase adjustment and power, and also has the functions of pulse output and simulating DC resistance, thermocouple (TC), thermal resistance (RTD) and capacitance. Applied to calibrate 6 and below digits multimeters or other electrical measuring instruments.

    Reference

    • JJG 124-2005 Verification Regulation of Amperemeters, Voltmeters, Wattmeters and Ohmmeters.

    • JJF 1587-2016 Calibration Specification for Multimeters

    • JJF 1284-2011 Calibration Specification of Calibrators for Electrical Meters

    • JJF 1638-2017 Calibration specification of multifunctional standard source

    Features

    • Electrical Parameters Output: Voltage is up to 1100 V, current is up to 30 A at a frequency 10 Hz ~ 500 kHz.

    • Resistance Simulation: Continuously variable range, 1 ~ 1100 M, pulse output range: 1 Hz ~ 2 MHz.

    • The output current has high stability (the typical value is better than 10 ppm/h) and high accuracy (the typical value is 50 ppm/a), and its measurement accuracy is higher than the international similar products.

    • Value Adjustment Method: Fixed-point, rotary encoder, step and potentiometer (option).

    • Output Switch: The output can be turned on/off arbitrarily by one-touch operation.

    • TC and RTD simulation: Support for simulation of up to 8 types of TC and 6 types of RTD.

    • Strong load capacity of AC, can drive various types of analogue meters and digital meters, so the applicable range of measured instruments is very wide.

    • The protection of voltage and current sources ensures high reliability under complex conditions.

    • Excellent Human-Computer Interaction: Large LCD touch screen display, touch and button operation modes, easy for users to measure manually.

    • Transmitter Measurement (Option): Measure the secondary DC signal of the transmitters.

    • Proprietary Software (Option): Support the calibration of the checked meters by semi-automatic or full-automatic, data management and report export.

    Specification

    AC Voltage Output

    Range Resolution Frequency (Hz) Accuracy (k = 2, ppm*RD +μV)

    Max. Load

    Current (mA)

    90 Days

    (23 ±5) °C

    1 Year

    (23 ±5) °C

    30 mV 100 nV 10 ≤ F≤ 45 600 + 6 800 + 6 50
    45 < F < 400 80 + 5 100 + 5
    400 < F < 10 k 80 + 10 100 + 10
    10 k < F < 20 k 160 + 10 200 + 10
    20 k < F < 50 k 800 + 10 1000 + 10
    50 k < F < 100 k 2800 + 12 3500 + 12
    100 k < F < 500 k 6000 + 50 8000 + 50
    100 mV 1 μV 10 ≤ F≤ 45 250 + 8 300 + 8 50
    45 < F < 400 80 + 5 100 + 5
    400 < F < 10 k 80 + 10 100 + 10
    10 k < F < 20 k 80 + 10 200 + 10
    20 k < F < 50 k 280 + 10 350 + 10
    50 k < F < 100 k 640 + 10 800 + 10
    100 k < F < 500 k 1600 + 70 2000 + 70
    300 mV 1 μV 10 ≤ F≤ 45 250 + 8 300 + 8 100
    45 < F < 10 k 80 + 10 100 + 10
    10 k < F < 20 k 80 + 10 200 + 10
    20 k < F < 50 k 280 + 10 350 + 10
    50 k < F < 100 k 640 + 10 800 + 10
    100 k < F < 500 k 1600 + 70 2000 + 70

    1 V

    10 μV 10 ≤ F≤ 45 250 + 50 300 + 50 100
    45 < F < 400 40 + 20 50 + 20
    400 < F < 10 k 80 + 20 100 + 20
    10 k < F < 20 k 160 + 20 200 + 20
    20 k < F < 50 k 280 + 20 350 + 20
    50 k < F < 100 k 640 + 20 800 + 20
    100 k < F < 500 k 2000 + 600 2400 + 600
    3 V 10 μV 10 ≤ F≤ 45 250 + 50 300 + 50 100
    45 < F < 400 40 + 50 50 + 50
    400 < F < 2 k 64 + 50 80 + 50
    2 k < F < 10 k 80 + 50 100 + 50
    10 k < F < 20 k 160 + 50 200 + 50
    20 k < F < 50 k 280 + 50 350 + 50
    50 k < F < 100 k 640 + 50 800 + 50
    100 k < F < 500 k 2000 + 600 2400 + 600
    10 V 100 μV 10 ≤ F≤ 15 250 + 30000 300 + 30000 100
    15 < F < 45 250 + 650 300 + 650
    45 < F < 400 40 + 150 50 + 150
    400 < F < 2 k 64 + 150 80 + 150
    2 k < F < 10 k 80 + 150 100 + 150
    10 k < F < 20 k 160 + 150 200 + 150
    20 k < F < 50 k 280 + 150 350 + 150
    30 V 100 μV 10 ≤ F≤ 15 250 + 80000 300 + 30000 250
    15 < F < 45 250 + 650 300 + 650
    45 < F < 400 40 + 500 50 + 500
    400 < F < 2 k 64 + 500 80 + 500
    2 k < F < 10 k 80 + 500 100 + 500
    10 k < F < 20 k 160 + 500 200 + 500
    20 k < F < 50 k 280 + 500 350 + 500
    100 V 1 mV 15 < F < 45 250 + 2000 300 +2000 250
    45 < F < 400 40 + 1000 50 +1000
    400 < F < 2 k 64 + 1000 80 + 1000
    2 k < F < 10 k 80 + 1000 100 + 1000
    10 k < F < 20 k 160 + 1000 200 + 1000
    20 k < F < 50 k 280 + 1000 350 + 1000
    300 V 1 mV 15 < F < 45 250 + 6000 300 + 6000 100
    45 < F < 400 50 + 5000 50 + 5000
    400 < F < 2 k 80 + 5000 80 + 5000
    2 k < F < 10 k 80 + 5000 100 + 5000
    10 k < F < 20 k 160 + 5000 200 + 5000
    20 k < F < 50 k 280 + 5000 350 + 5000
    1000 V

    10 mV

    45 ≤ F≤ 400 80 + 10000 100 + 10000 30
    400 < F < 2 k 96 + 10000 120 + 10000
    2 k < F < 10 k 120 + 10000 150 + 10000
    • Output Range: 3 mV ~ 1100 V; Display: 7 digits;

    • Distortion: <0.5 %;<1 % @ 10 mV…1 V ranges

    • Protection: Short-circuit protection, overload protection.

    AC Current Output

    Range Resolution Frequency (Hz) Accuracy (k = 2, ppm*RD +μV)

    Max. Load

    Current (mA)

    90 Days

    (23 ±5) °C

    1 Year

    (23 ±5) °C

    300 μA 1 nA 10 ≤ F≤ 20 400 + 0.2 500 + 0.2 30
    20 < F < 45 300 + 0.1 350 + 0.1
    45 < F < 400 240 + 0.1 300 + 0.1
    400 < F < 2 k 320 + 0.2 400 + 0.2
    2 k < F < 10 k 400 + 0.5 500 + 0.5
    10 k < F < 20 k 4000 + 0.6 5000 + 0.6
    20 k < F < 50 k 6400 + 0.7 8000 + 0.7
    1 mA 10 nA 10 ≤ F≤ 20 400 + 0.5 500 + 0.5 30
    20 < F < 45 200 + 0.1 250 + 0.1
    45 < F < 400 160 + 0.1 200 + 0.1
    400 < F < 2 k 160 + 0.2 200 + 0.2
    2 k < F < 10 k 240 + 0.5 300 + 0.5
    10 k < F < 20 k 2400 + 0.6 3000 + 0.6
    20 k < F < 50 k 5600 + 0.7 7000 + 0.7
    3 mA 10 nA 10 ≤ F≤ 20 400 + 1.5 500 + 1.5 30
    20 < F < 45 200 + 0.1 250 + 0.1
    45 < F < 400 160 + 0.1 200 + 0.1
    400 < F < 2 k 160 + 0.2 200 + 0.2
    2 k < F < 10 k 240 + 0.5 300 + 0.5
    10 k < F < 20 k 1600 + 0.6 2000 + 0.6
    20 k < F < 50 k 4800 + 0.7 6000 + 0.7
    10 mA 100 nA 10 ≤ F≤ 20 400 + 5 500 + 5 30
    20 < F < 45 200 + 0.5 250 + 0.5
    45 < F < 400 80 + 0.5 100 + 0.5
    400 < F < 2 k 160 + 1 200 + 1
    2 k < F < 10 k 400 + 2 500 + 2
    10 k < F < 20 k 1600 + 3 2000 + 3
    20 k < F < 50 k 4800 + 4 6000 + 4
    30 mA 100 nA 10 ≤ F≤ 20 400 + 15 500 + 15 30
    20 < F < 45 200 + 2 250 + 2
    45 < F < 400 80 + 2 100 + 2
    400 < F < 2 k 160 + 3 200 + 3
    2 k < F < 10 k 400 + 5 500 + 5
    10 k < F < 20 k 1600 + 6 2000 + 6
    20 k < F < 50 k 4800 + 7 6000 + 7
    100 mA 1 μA 10 ≤ F≤ 20 400 + 50 500 + 50 30
    20 < F < 45 200 + 5 250 + 5
    45 < F < 400 40 + 5 50 + 5
    400 < F < 2 k 80 + 10 100 + 10
    2 k < F < 10 k 160 + 20 200 + 20
    10 k < F < 20 k 800 + 30 1000 + 30
    20 k < F < 30 k 2400 + 40 3000 + 40
    30 k < F < 50 k 5000 + 40 6000 + 40
    1 A 10 μA 10 ≤ F≤ 20 400 + 500 500 + 500 15
    20 < F < 45 200 + 20 250 + 20
    45 < F < 400 40 + 50 50 + 50
    400 < F < 2 k 50 + 100 50 + 100
    2 k < F < 10 k 160 + 500 200 + 500
    10 k < F < 20 k 800 + 600 1000 + 600
    20 k < F < 30 k 2400 + 700 3000 + 700
    3 A 10 μA 10 ≤ F≤ 20 400 + 1500 500 + 1500 10
    20 < F < 45 200 + 100 250 + 100
    45 < F < 400 40 + 100 50 + 100
    400 < F < 2 k 80 + 100 100 + 100
    2 k < F < 10 k 160 + 500 200 + 500
    10 A 100 μA 45 < F < 400 40 + 200 50 + 200 2.5
    400 < F < 2 k 80 + 200 100 + 200
    2 k < F < 10 k 160 + 500 200 + 500
    30 A 100 μA 45 ≤ F≤ 400 80 + 600 100 + 600 2
    400 < F < 2 k 80 + 600 100 + 600
    2 k < F < 5 k 160 + 1500 200 + 1500
    • Output Range: 30 μA ~ 30 A; Display: 7 digits;

    • Distortion: <0.5 %;<1 % @ 300 μA…10 mA ranges

    • Protection: Short-circuit protection, overload protection.

    DC Voltage Output

    Range Accuracy (K = 2) (ppm*RD + μV)

    Max. Load Current

    (mA)

    Ripple Coefficient

    (%)

    24 Hours 90 Days 1 Year
    30 mV 15 + 2 24 + 2 30 + 2 50 < 0.5
    100 mV 12 + 2 20 + 2 25 + 2 50 < 0.5
    300 mV 10 + 2 16 + 2 20 + 2 100 < 0.5
    1 V 10 + 2 16 + 2 20 + 2 100 < 0.5
    3 V 8 + 5 12 + 5 15 + 5 100 < 0.5
    10 V 8 + 10 12 + 10 15 + 10 100 < 0.5
    30 V 8 + 20 12 + 20 15 + 20 250 < 0.5
    100 V 10 + 100 16 + 100 20 + 100 250 < 0.5
    300 V 10 + 300 16 + 300 20 + 300 100 < 0.5
    1000 V 10 + 1500 16 + 1500 20 + 1500 30 < 0.5
    • Output Range: ±(3 mV ~ 1100 V); Resolution: 0.0005 %*RG; Display: 7 digits

    • Range Switching: Automatic or Manual.

    DC Current Output

    Range

    Accuracy (K = 2)

    (ppm*RD + ppm*RG)

    Max. Load Voltage

    (V)

    Ripple Coefficient

    (%)

    24 Hours

    90 Days

    1 Year
    30 μA 50 + 0.01 80 + 0.01 100 + 0.01 11 < 0.5
    100 μA 50 + 0.02 80 + 0.02 100 + 0.02 11 < 0.5
    300 μA 50 + 0.02 80 + 0.02 100 + 0.02 11 < 0.5
    1 mA 25 + 0.05 40 + 0.05 50 + 0.05 11 < 0.5
    3 mA 25 + 0.05 40 + 0.05 50 + 0.05 11 < 0.5
    10 mA 25 + 0.2 40 + 0.2 50 + 0.2 11 < 0.5
    30 mA 25 + 0.5 40 + 0.5 50 + 0.5 11 < 0.5
    100 mA 25 + 1 40 + 1 50 + 1 11 < 0.5
    1 A 25 + 20 40 + 20 50 + 20 4 < 0.5
    3 A 25 + 50 40 + 50 50 + 50 4 < 0.5
    10 A 25 + 200 40 + 200 50 + 200 4 < 0.5
    30 A 30 + 600 48 + 600 60 + 600 3.5 < 0.5
    • Output Range: ±(3 μA ~ 30 A); Resolution: 0.0005 %*RG; Display: 7 digits

    • Range Switching: Automatic or Manual.

    AC/DC Power Output

    DC Power Range Combination of DC voltage range and DC current range.
    Accuracy DC voltage accuracy + DC current accuracy.

    AC Power

    (45 Hz ~ 65 Hz)

    Range Combination of 30 V...300 V range and 10 mA…30 A range.
    Accuracy Range of 10 mA…30 mA: 0.05 %*FS
    Range of 100 mA…30 A: 0.02 %*FS
    Power Factor -1.0000…0.0000…+1.0000
    • Active Power (|cosφ| ≥0.5), Reactive Power (|sinφ| ≥0.5)

    Capacitance

    Range Accuracy (k = 2) (%*RD+ nF or μF) Resolution Allowable Frequency
    1.1 nF ~ 3.2999 nF 0.5 + 0.04 nF 0.1 pF 10 Hz ~ 3 kHz
    3.3 nF ~ 10.9999 nF 0.25 + 0.04 nF 0.1 pF 10 Hz ~ 1 kHz
    11 nF ~ 32.9999 nF 0.25 + 0.4 nF 0.1 pF 10 Hz ~ 1 kHz
    33 nF ~ 109.999 nF 0.25 + 0.4 nF 1 pF 10 Hz ~ 1 kHz
    110 nF ~ 329.999 nF 0.25 + 0.3 nF 1 pF 10 Hz ~ 1 kHz
    330 nF ~ 1.09999 μF 0.25 + 1 nF 10 pF 10 ~ 600 Hz
    1.1 μF ~ 3.29999 μF 0.25 + 3 nF 10 pF 10 ~ 300 Hz
    3.3 μF ~ 10.9999 μF 0.25 + 10 nF 100 pF 10 ~ 150 Hz
    11 μF ~ 32.9999 μF 0.40 + 30 nF 100 pF 10 ~ 120 Hz
    33 μF ~ 109.999 μF 0.45 + 100 nF 1 nF 10 ~ 80 Hz
    110 μF ~ 329.999 μF 0.45 + 300 nF 1 nF 0 ~ 50 Hz
    330 μF ~ 1.09999 mF 0.45 + 1 μF 10 nF 0 ~ 20 Hz
    1.1 mF ~ 3.29999 mF 0.45 + 3 μF 10 nF 0 ~ 6 Hz
    3.3 mF ~ 10.9999 mF 0.45 + 10 μF 100 nF 0 ~ 2 Hz
    11 mF ~ 30 mF 0.75 + 30 μF 100 nF 0 ~ 0.6 Hz

    Resistance

    Range Allowable Current Accuracy (k = 2), ppm*RD +Ω
    24 Hours

    90 Days

    1 Year
    10 Ω 1 mA ~ 150 mA 20 + 0.01 32 + 0.01 40 + 0.01
    20 Ω 1 mA ~ 150 mA 15 + 0.015 24 + 0.015 30 + 0.015
    100 Ω 1 mA ~ 80 mA 12 + 0.015 20 + 0.015 25 + 0.015
    300 Ω 1 mA ~ 40 mA 12 + 0.02 20 + 0.02 25 + 0.02
    1 kΩ 1 mA ~ 20 mA 12 + 0.02 20 + 0.02 25 + 0.02
    3 kΩ 0.1 mA ~ 6 mA 12 + 0.2 20 + 0.2 25 + 0.2
    10 kΩ 0.1 mA ~ 2 mA 12 + 0.2 20 + 0.2 25 + 0.2
    30 kΩ 10 μA ~ 600 μA 15 + 1 24 + 1 30 + 1
    100 kΩ 10 μA ~200 μA 15 + 1 24 + 1 30 + 1
    300 kΩ 1 μA ~ 60 μA 17 + 10 28 + 10 35 + 10
    1 MΩ 1 μA ~ 20 μA 17 + 10 28 + 10 35 + 10
    3 MΩ 250 nA ~ 6 μA 30 + 150 48 + 150 60 + 150
    10 MΩ 250 nA ~ 2 μA 65 + 250 104 + 250 130 + 250
    30 MΩ 25 nA ~ 600 nA 125 + 2.5 k 200 + 2.5 k 250 + 2.5 k
    100 MΩ 25 nA ~ 200 nA 250 + 3 k 400 + 3 k 500 + 3 k
    300 MΩ 2.5 nA ~ 60 nA 1,5 k + 0.1 M 2.4 k + 0.1 M 3 k + 0.1 M
    1000 MΩ 1 nA ~ 20 nA 7.5 k + 0.5 M 12 k + 0.5 M 15 k + 0.5 M
    • Output Range of Resistance: 0 Ω ~ 1100 MΩ; Resolution: 0.0004 %*RG; Display: 7 digits

    Thermal Resistance (RTD)

    Type Temperature Range (°C) Accuracy (k = 2) (°C)
    90 Days 1 Year
    Pt385, 100 Ω -200 ~ 0 0.05 0.05
    0 ~ 300 0.08 0.08
    300 ~ 850 0.12 0.12
    Pt385,200 Ω -200 ~ 250 0.04 0.04
    250 ~ 630 0.10 0.15
    Pt385,500 Ω -200 ~ -30 0.36 0.40
    -30 ~ 630 0.10 0.11
    Pt385,1000 Ω -200 ~ 0 0.027 0.03
    0 ~ 300 0.054 0.060
    300 ~ 600 0.063 0.070
    CU50 -50 ~ 150 0.09 0.09
    CU100 -50 ~ 150 0.045 0.045

    Thermocouple (TC)

    Type Temperature Range (°C) Accuracy (k = 2) (°C)
    90 Days 1 Year
    B 410 ~ 600 0.30 0.35
    600 ~ 900 0.30 0.31
    900 ~ 1800 0.26 0.30
    E -200 ~ 0 0.10 0.11
    0 ~ 600 0.07 0.08
    600 ~ 1000 0.09 0.10
    J -200 ~ -100 0.12 0.13
    -100 ~ 750 0.09 0.09
    750 ~ 1200 0.10 0.10
    K -200 ~ -100 0.15 0.20
    -100 ~ 1000 0.10 0.10
    1000 ~ 1370 0.12 0.12
    N -200 ~ -100 0.20 0.25
    -100 ~ 400 0.12 0.12
    400 ~ 1300 0.10 0.12
    R -50 ~ 50 0.30 0.40
    50 ~ 300 0.28 0.32
    300 ~ 1000 0.22 0.23
    1000 ~ 1750 0.25 0.25
    S -50 ~ 50 0.30 0.40
    50 ~ 300 0.31 0.34
    300 ~ 1000 0.24 0.24
    1000 ~ 1750 0.22 0.23
    T -200 ~ -100 0.17 0.25
    -100 ~ 0 0.08 0.11
    0 ~ 400 0.08 0.08

    Pulse

    • Frequency Range: 1 Hz ~ 2 MHz, TTL Level

    • Resolution: 0.001 %*RG

    • Accuracy: ±(0.002 %*RD + 20 μHz)

    • Jitter: <20 ns

    DC Small Signal Measurement (Option)

    • Range: 1 V, 10 V, 2 mA, 20 mA

    • Measuring Range: ± (0 ~12 V);± (0 ~ 24 mA)

    • Accuracy: ±(0.006 %*RD + 0.004 %*RG)

    • Notes: Applied to measure the secondary DC signal of the transmitters.

    Quality TD1880 Fluke Multifunction Calibrator High Precision Multi Product Calibrator for sale
    Company Info.
    Tunkia Co., Ltd.
    Verified Supplier
    View Contact Details
    Product List
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Tunkia Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Fluke Multifunction Calibrator products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0