Sign In | Join Free | My himfr.com
Home > Other Electrical Equipment >

TD1600 Fluke Multifunction Calibrator High Precision Single Phase AC Calibrator

    Buy cheap TD1600 Fluke Multifunction Calibrator High Precision Single Phase AC Calibrator from wholesalers
     
    Buy cheap TD1600 Fluke Multifunction Calibrator High Precision Single Phase AC Calibrator from wholesalers
    • Buy cheap TD1600 Fluke Multifunction Calibrator High Precision Single Phase AC Calibrator from wholesalers

    TD1600 Fluke Multifunction Calibrator High Precision Single Phase AC Calibrator

    Ask Lasest Price
    Model Number : TD1600
    Brand Name : TUNKIA
    Price : negotiation
    Payment Terms : negotiation
    • Product Details
    • Company Profile

    TD1600 Fluke Multifunction Calibrator High Precision Single Phase AC Calibrator

    TD1600 Precision AC Calibrator

    Introduction

    • TD1600, a single-phase AC calibrator with wide range, high precision and multifunction.

    • The apparatus can output high accuracy AC voltage, current and power, and the optional accuracy are 0.05% and 0.02%. Applied to calibrate various AC electrical measuring instruments.

    Features

    • AC Electrical Parameter Output: Voltage is up to 1100 V, current is up to 110 A.

    • Frequency and Phase Adjustment: Frequency: 45 Hz ~ 70 Hz.

    • AC Power Output: Measure the active power, reactive power, apparent power and power factor.

    • Value Output Mode: Standard source and output source modes, easy to calibrate both digital meters and analogue meters.

    • Value Adjustment Method: Fixed-point, rotary encoder, step and potentiometer (option).

    • Output Switch: The output can be turned on/off arbitrarily by one-touch operation.

    • Automatical Error Calculation: Set the measured values of the checked meter, and adjust the value output to automatically calculate the errors of the checked meter.

    • Excellent Human-computer Interaction: Large LCD touch screen display, touch and button operation modes, easy for users to measure manually.

    • Harmonic (Option): Load 2nd to 31st harmonics with variable amplitude and phase for impact test.

    • Proprietary Software (Option): Support the calibration of the checked meters by semi-automatic or full-automatic, data management and report export.


    Specification


    AC Voltage Output

    RangeStability (%/min)

    Accuracy (k = 2)

    (ppm*RD + ppm*RG)

    Max. Load Current

    (mA)

    0.05%0.02%0.05%0.02%
    1 V0.010.005300 + 200120 + 80500
    3 V0.010.005300 + 200120 + 80500
    10 V0.010.005300 + 200120 + 80500
    30 V0.010.005300 + 200120 + 80500
    60 V0.010.005300 + 200120 + 80800
    100 V0.010.005300 + 200120 + 80500
    150 V0.010.005300 + 200120 + 80400
    200 V0.010.005300 + 200120 + 80250
    300 V0.010.005300 + 200120 + 80150
    400 V0.010.005300 + 200120 + 80100
    600 V0.010.005300 + 200120 + 8080
    750 V0.010.005300 + 200120 + 8060
    1000 V0.010.005300 + 200120 + 8050

    AC Current Output

    RangeStability (%/min)

    Accuracy (k = 2)

    (ppm*RD + ppm*RG)

    Max. Inductive

    Load (V)

    0.05%0.02%0.05%0.02%
    1 mA1 μA0.5 μA300 + 2 μA120 + 1 μA120
    2 mA1 μA0.5 μA300 + 2 μA120 + 1 μA120
    5 mA1 μA0.5 μA300 + 2 μA120 + 1 μA120
    10 mA0.010.005300 + 200120 + 80120
    20 mA0.010.005300 + 200120 + 80120
    50 mA0.010.005300 + 200120 + 80120
    100 mA0.010.005300 + 200120 + 80120
    200 mA0.010.005300 + 200120 + 80120
    500 mA0.010.005300 + 200120 + 80100
    1 A0.010.005300 + 200120 + 8050
    2 A0.010.005300 + 200120 + 8025
    5 A0.010.005300 + 200120 + 8010
    10 A0.010.005300 + 200120 + 805
    20 A0.010.005300 + 200120 + 802.5
    30 A0.010.005300 + 200120 + 802.5
    50 A0.010.005300 + 200120 + 801.5
    100 A0.010.005300 + 200120 + 800.8

    Output Characteristics of Voltage and Current

    • Output Range of Voltage: 100 mV ~ 1100 V

    • Output Range of Current: 0.1 mA/ 20 mA ~ 110 A

    • Range Switching: Automatic or Manual.

    • Resolution: 0.001 %*RG; Display: 6 digits; Distortion: <0.2 %

    • 1 mA,2 mA,5 mA are small range option.


    Frequency, Phase and Harmonic (Option)

    TypeRangeResolutionAccuracy
    Frequency45.000 Hz ~ 70.000 Hz0.001 Hz0.005 Hz
    Phase0.0000 ° ~ 359.9999 °0.005 °0.05 °
    TypeOrderAmplitudeVariable Phase
    Harmonic2nd to 31st0 ~ 25 %0 ~ 359.9 °

    Power Output

    TypeStability (%/min)Accuracy (k = 2) %*FS
    0.05%0.02%0.05%0.02%
    Active Power0.010.0050.050.025
    Reactive Power0.020.010.10.05
    Apparent Power0.020.010.10.05
    Power Factor0.020.010.10.05
    • Output Range of AC Power: Combination of AC voltage range and AC current range.

    • Range of Power Factor: -1.0000…0.0000…+1.0000

    • Active Power (|cosφ| ≥0.5), Reactive Power (|sinφ| ≥0.5)

    Quality TD1600 Fluke Multifunction Calibrator High Precision Single Phase AC Calibrator for sale
    Company Info.
    Tunkia Co., Ltd.
    Verified Supplier
    View Contact Details
    Product List
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Tunkia Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Fluke Multifunction Calibrator products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0