Sign In | Join Free | My himfr.com |
|
...Metering CT Test & Production Line System with Block-Based Design for Mass Production Safe and Reliable Fully Automatic Metering CT Test Production Line System with Block-Based Design for Mass Production Fun...
HS-6325 Three PHASE ENERGY METER AGING TEST BENCH Operating environment:Temperature -20~80℃, Relative humidity≦75% Input power supply:220V AC,+/-10%, 45~65Hz. Positions: 48 meters Quick connection: Sequential a...
Single & Three Phase Meter Test Bench MCTB20B Technical Parameters Accuracy class 0.05, 0.1 (optional) Output Voltage Range 3*(1-450V) (P-N) Resolution 0.01% THD <0.5% Accuracy & Stability 0.05% or 0.02% Capacity ≥ 800VA/phase (20 positions) Current output......
Single & Three Phase Meter Test Bench MCTB20B Technical Parameters Accuracy class 0.05, 0.1 (optional) Output Voltage Range 3*(1-450V) (P-N) Resolution 0.01% THD <0.5% Accuracy & Stability 0.05% or 0.02% Capacity ≥ 800VA/phase (20 positions) Current output......
...meter test equipment KE8103 has two current sources, which make it possible to test two elements simultaneously. It is used for testing 1P2W or 3P3W mechanical and electric meter, Number of meter position : ...
...-phase wide range voltage & current source and a single-phase electronic reference standard meter of accuracy class 0.05%. It is wide measuring range, 0.05% class high accuracy ,high tolerance to unwanted ex...
...meter test bench KE8104 has double current channels with ICT isolation, used for 2 element single phase mechanical and electric meter, Number of meter position: 3-48 Features: 1. Integrated / Separated alumi...
...Meter MCSB03B 1) Small size and weight 2) Used in lab or worksite 3) Work as standard meter and calibrator in worksite or lab 4) LCD display 5) Accuracy class: 0.05 or 0.02 (optional) 6) Measuring range: 3*(...
...Meter MCSB03B 1) Small size and weight 2) Used in lab or worksite 3) Work as standard meter and calibrator in worksite or lab 4) LCD display 5) Accuracy class: 0.05 or 0.02 (optional) 6) Measuring range: 3*(...
...,Macro-adjustable phase:30°/shift, Micro-adjustable phase:0.1° Multiplex voltage separation PT is provided for each meter hanger carrier to ensure equal battery level of each meter station during electric me...
Portable Meter Test Equipment Three Phase Reference Standard Meter MCST01C Technical Parameters Current Measure Direct mode range 1mA-120A Clamp-on CT range selectable 5A, ......
Portable Meter Test Equipment Three Phase Reference Standard Meter MCST01C Technical Parameters Current Measure Direct mode range 1mA-120A Clamp-on CT range selectable 5A, ......
Single and Three Phase Meter Test Bench MCSY31-01A Device configuring and structural requirement 1. A beautiful and dignified appearance: special aluminum alloy with integral construction; fire-resisting table ...
Single and Three Phase Meter Test Bench MCSY31-01A Device configuring and structural requirement 1. A beautiful and dignified appearance: special aluminum alloy with integral construction; fire-resisting table ...
Output voltage and current distortion not larger than 0.3%(if it is a linear load) The variation of pre-set output power within 180S will not exceed 0.02% compared with the measurement range Number of harmonic ...
...-576V Harmonics test: up to 51 times Burden test/voltage range: 0-5V Frequency Range: 45-65HZ Phase angle range: 0-360 deg. Power factor range: 0 to 1 ......
...-576V Harmonics test: up to 51 times Burden test/voltage range: 0-5V Frequency Range: 45-65HZ Phase angle range: 0-360 deg. Power factor range: 0 to 1 ......
... extrusions frame, special material for this bench rack 3. Can test three phase four wire meter, three phase three wire active, three phase four wire reactive, three phase three wire reactive meter 4. With v...
... extrusions frame, special material for this bench rack 3. Can test three phase four wire meter, three phase three wire active, three phase four wire reactive, three phase three wire reactive meter 4. With v...
Single Phase Meter Aging and Cyclometer Test Equipment 1. Widely used in meter factories 2. Stable qualtity and economic budget 3. 96 positions Feature & Characteristic 1. Whole system mainly including source a...