    Brand Name : GENY
    Model Number : YC89S1
    Certification : ISO, CE
    Payment Terms : L/C,T/T,D/P
    • Product Details
    • Company Profile

     YC-98S1 Portable Three Phase Standard Meter

    YC-98S1 Portable Three Phase Standard Meter



    The instrument YC98S1 is used to calibrate three phase, single phase, active or reactive energy meter who comply with GB/T17215.211 (IEC62052-11), GB/T17215.311 /321/322/323 (IEC62053-11/21/22/23), and also it can be used as voltage, current and power meter to measure AC parameter of three phase power grid.

    This portable three phase standard meter comply to GB/T11150-2001 (IEC60736:2001), GB/T4793.2-2008 (IEC61010-1:2001)


    Product Parameters



    Test Voltage (Full Wave & Fundamental Wave)



    Range

    0~500V



    Error

    ±0.05% (0.1%)



    Harmonic

    2nd ~ 51st



    Test Current (Full Wave & Fundamental Wave)



    Range (direct connection)

    0.025A ~ 12A (Ie=5A)



    Range (100AClamp CT)

    0.5~120A (Ie=100A,usage range=0.01Ie~2.4Ie)

    (Optional: Ie=5A, 500A, 1000A)



    Error (direct connection)

    ±0.05% (0.1%)



    Error (100AClamp CT)

    ±0.2%(5A,100A) ±0.5% (other)



    Harmonic

    2nd ~ 51st



    Starting current

    0.05%Ie



    Power Measure Error (Full Wave & Fundamental Wave)



    Active Power (Direct connection)

    ±0.05%



    Active Power (100A ClampCT)

    ±0.2%(5A,100A) ±0.5% (other)



    Reactive Power (Direct connection)

    ±0.1%



    Reactive Power (100A ClampCT)

    ±0.5%(5A,100A) ±1.0% (other)



    Energy Measure Error (Full Wave & Fundamental Wave)

    Active Energy (Direct connection)

    ±0.05% (±0.1%)

    Active Energy (100A ClampCT)

    ±0.2%(5A,100A) ±0.5% (other)

    Reactive Energy (Direct connection)

    ±0.1%

    Reactive Energy (100A ClampCT)

    ±0.5%(5A,100A) ±1.0% (other)

    Error (Harmonic Wave)

    Direct Connection

    kWh,U, I, P, Q, S

    ±0.2%H (H=1+0.01k, k=2~51)

    Clamp CT 5A/100A

    kWh,U, I, P, Q, S

    ±0.5%H (H=1+0.01k, k=2~51)

    Cycle Output Current for 5A CCT’s Self Calibration

    0.05A,0.1A,0.25A,0.5A,1A,2.5A,5A

    Error of 5ACCT’s Self Calibration

    (linear and phase error)

    ±0.1%

    Clamp CT 500A/1000A

    kWh,U, I, P, Q, S

    ±1.0%H (H=1+0.01k, k=2~51)

    Error - Others

    Ratio Measurement

    ±0.5%

    Voltage Influence

    <±0.01%

    Frequency Influence

    <±0.01%

    Temperature Influence

    <±0.01%/℃

    24h Accuracy Influence

    <±0.01%

    Harmonic Influence

    <±0.01%

    Phase angle

    Range

    -180°~ 180°

    Error

    <±0.1°

    Frequency

    Range

    45 ~ 65Hz

    Error

    ±0.01Hz

    Pulse output

    Inner High frequency (CH)

    Direct connection

    1.8x109 P/kWh

    Clamp CT

    1.8x109 *(5/Ie)P/kWh

    Low frequency output

    Direct connection

    3600P, 36000P,

    360000P/kWh(kvarh, kVAh)

    Clamp CT

    3600P, 36000P, 360000P

    *(5/Ie)P/kWh(kvarh, kVAh)

    Pulse ratio

    1:1

    Output level

    +5V (can be adjusted according to request)

    Pulse input

    Input Channel

    2

    Input level

    5 ~ 10V

    Max Pulse Input frequency

    Max. 10kHz

    Display

    Resolution

    7’’TFT Touch Screen

    System

    Windows CE

    Other

    Voltage supply mode

    External power, Tested circuit, Battery

    Working power supply

    AC 55~600V

    Voltage Withstand

    4.0kV (voltage ¤t terminals, power supply & low voltage terminals)

    EFT(Electrical Fast Transient)

    2.0kV

    IP Level

    IP51

    Surge

    2.0kV (common mode), 2.0kV (different mode)

    Power on Stability Time

    < 3mins

    Chargeable battery

    11.1V 3000mAh

    Power Consumption

    <9W

    Operation Temperature

    Temperature -20℃ ~ +55℃, humidity 40% ~ 95%

    Storage Temperature

    Temperature -40℃ ~ +80℃, humidity 40% ~ 95%

    Dimension (mm) (W×H×D)

    Main

    245×150×50

    Carry case

    425×336×196

    Weight (kg)

    Main

    2

    Whole set

    10



    Test Functions


    1.Multi-Meter Testing:

    Tests one or two meters simultaneously, with error display precise to five digits and three decimal places.

    2.Automated/Manual Testing:

    Automated test sequence for electronic and electromechanical meters.

    Manual control via start/stop button or firmware.

    3.Data Calculation and Display:

    Displays full wave, fundamental wave, harmonic wave data, and U, I, P, Q, VA, phase angle.

    Shows positive/negative sequence, zero sequence, and harmonic content.

    4.Energy Accuracy Testing:

    Tests active/reactive energy for full wave, fundamental wave, and harmonic wave meters.

    Tests apparent energy accuracy.

    5.Dual-Channel Pulse Testing:

    Simultaneous testing of two channels with different pulse constants and modes.

    6.Wiring Identification and Energy Accumulation:

    Identifies wiring without load.

    Measures energy meters without pulse output.

    7.Dial Test Function:

    Time method or energy method available.

    8.Waveform and Vector Display:

    Displays vector diagrams and three-phase voltage/current waveforms.

    9.Wrong Wiring Identification:

    Detects 48 types of three-phase and 96 types of four-wire connections.

    Identifies CT secondary crossing wiring.

    10.Wiring Simulation and Training:

    Simulates wiring scenarios for training and parameter revision without voltage/current signals.


    Harmonic Functions


    1.Harmonic Analysis:

    Calculates harmonic compound of U, I, P, Q, VA and their percentages.

    Analyzes up to 51st harmonic (+PH/-PH) and their impact on meter metrology.

    2.Full Wave Reactive Power:

    Algebraic sum of fundamental and harmonic waves.

    Avoids errors from 90-degree phase shift method by selecting harmonic wave numbers based on meter bandwidth.



    Quality  YC-98S1 Portable Three Phase Standard Meter for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Guangzhou GENY Electric Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Portable Reference Standard products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0