Sign In | Join Free | My himfr.com
Home > Other Shoes >

High Pressure Feed Effluent Heat Exchanger for Hydrocracking

    Buy cheap High Pressure Feed Effluent Heat Exchanger for Hydrocracking from wholesalers
     
    Buy cheap High Pressure Feed Effluent Heat Exchanger for Hydrocracking from wholesalers
    • Buy cheap High Pressure Feed Effluent Heat Exchanger for Hydrocracking from wholesalers
    • Buy cheap High Pressure Feed Effluent Heat Exchanger for Hydrocracking from wholesalers
    • Buy cheap High Pressure Feed Effluent Heat Exchanger for Hydrocracking from wholesalers
    • Buy cheap High Pressure Feed Effluent Heat Exchanger for Hydrocracking from wholesalers

    High Pressure Feed Effluent Heat Exchanger for Hydrocracking

    Ask Lasest Price
    Model Number : Feed Effluent Heat Exchanger
    Delivery Time : 20-80 DAYS
    Payment Terms : T/T,L/C
    Price : NEGOCIATED
    Certification : ASME, ABS, DNV-GL , BV, LR , KR, CCS, PED, TUV, ISO9001, AD2000
    Supply Ability : 500 TONS
    Brand Name : YUHONG
    • Product Details
    • Company Profile

    High Pressure Feed Effluent Heat Exchanger for Hydrocracking

    High‑Pressure Feed Effluent Heat Exchanger for Hydrocracking | U‑Tube / Floating Head Design | Chrome‑Moly Steel Construction – ASME Code Fabrication for Refinery Service

    Need a custom quote for Feed Effluent Heat Exchanger? Contact our engineering team directly: [email protected]

    Product Description

    Yuhong Group: Engineered Heat Exchangers for Critical Refinery Service

    Yuhong Group Co., Ltd. designs and manufactures high‑performance thermal equipment for demanding industrial applications. Our core offerings include shell & tube heat exchangers, pressure vessels, and air coolers – with a special focus on high‑pressure, high‑temperature exchangers for hydroprocessing, hydrocracking, and refinery service.

    Shown in the attached photographs is one of our recent project deliveries – a Feed Effluent Heat Exchanger (801CB) for a hydrocracking unit. This is a critical piece of equipment that recovers heat from the reactor effluent and preheats the feed stream, significantly improving process energy efficiency.

    Product Focus: Feed Effluent Heat Exchanger – The Heart of Hydrocracking Energy Recovery

    The feed effluent heat exchanger is one of the most demanding services in a hydrocracking or hydrotreating unit. It transfers heat between the hot reactor effluent (typically 350‑450°C) and the cooler feed stream entering the reactor. This duty requires:

    • High‑temperature capability – continuous service at 350‑450°C

    • High‑pressure rating – typically 100‑200 bar (10‑20 MPa)

    • Hydrogen service compatibility – materials resistant to hydrogen attack and H₂S corrosion

    • Thermal stress management – large temperature differences require U‑tube or floating head design

    Based on the images, this exchanger exhibits:

    • Application: Hydrocracking unit feed/effluent service

    • Project: 801CB – core heat exchanger for the unit

    • Design type: U‑tube or floating head (to accommodate thermal expansion)

    • Material: Chrome‑molybdenum steel (F11/F22) with stainless steel or weld overlay cladding on hydrogen‑exposed surfaces

    • Construction: ASME Code compliant, U‑Stamp certified

    • Status: Successfully delivered to site

    Why U‑Tube or Floating Head Design for This Service?
    Design TypeAdvantage in Feed Effluent Service
    U‑TubeSingle tubesheet – no differential thermal expansion issues. Ideal for high temperature differentials between feed and effluent.
    Floating HeadAllows bundle removal for inspection; better access for cleaning if fouling is expected.

    The feed effluent exchanger typically uses a U‑tube design because the tube bundle can expand freely, and the single tubesheet eliminates the need for an expansion joint.

    Critical Components & Their Functions in This Exchanger
    ComponentTypical MaterialRole in Equipment Performance
    U‑Bend Heat Exchanger TubesChrome‑moly (F11/F22) or stainless steelCarry the reactor effluent; exposed to high temperature and hydrogen. U‑bend allows thermal expansion.
    Heat Exchanger TubesheetChrome‑moly steel (F22) with stainless weld overlayAnchors the U‑tubes; separates tube side (effluent) from shell side (feed). Overlay protects against hydrogen attack.
    ShellChrome‑moly steel (F11/F22)Contains the shell‑side feed stream; designed for high pressure (100‑200 bar).
    Channel / BonnetChrome‑moly steel (F22)Distributes the feed/effluent streams; designed for high‑pressure closure.
    BafflesChrome‑moly or stainless steelSupport U‑tubes; direct shell‑side flow for optimum heat transfer.
    Fin Tube (optional)Not typical in this serviceNot used in liquid‑to‑liquid high‑pressure exchangers.
    Impingement PlateStainless steel or alloyProtects tube bundle inlet from high‑velocity effluent erosion.
    Technical Highlights of Our Hydrocracking Feed Effluent Exchanger
    • Chrome‑molybdenum (Cr‑Mo) steel construction: F11 (1.25Cr‑0.5Mo) or F22 (2.25Cr‑1Mo) provides high‑temperature strength and resistance to hydrogen attack (per API 941 / Nelson Curve).

    • Stainless steel weld overlay: On hydrogen‑exposed surfaces (tubesheet, channel internal faces) – prevents hydrogen diffusion and surface corrosion.

    • U‑tube design: Eliminates thermal stress between shell and tube bundle – critical when ΔT > 50°C.

    • ASME U‑Stamp certified: Full code compliance; materials traceable to ASME Section II.

    • Stringent NDE: 100% RT/UT on welds; MT/PT on all pressure‑retaining surfaces.

    • Hydrogen service design: Material selection per API 941; hardness controls to prevent hydrogen‑induced cracking (HIC).

    Knowledge Module: Hydrocracking Feed Effluent Exchanger – The Most Critical Exchanger in the Unit

    In a typical hydrocracking unit, the feed effluent exchanger is the largest and most expensive heat exchanger in the process. Its failure can shut down the entire unit, costing millions per day.

    Key design challenges:

    1. High temperature differential: Feed enters at ~150‑200°C, effluent leaves the reactor at ~350‑450°C. The temperature difference across the exchanger is often >200°C – requiring U‑tube or floating head design.

    2. High hydrogen partial pressure: Hydrogen at high temperature can cause:

      • High‑temperature hydrogen attack (HTHA) – methane formation at grain boundaries

      • Hydrogen‑induced cracking (HIC) – blistering in susceptible steels

      Solution: Chrome‑moly steels (F11, F22) with proper heat treatment and hardness control.

    3. Ammonium bisulfide corrosion: Corrosion in the effluent cooling section from NH₄HS formation.

      Solution: Stainless steel or alloy cladding on tubesheets and channel internals.

    4. Thermal cycling: Shutdowns and startups cause thermal fatigue.

      Solution: Robust U‑tube design with adequate tube support and proper material selection.

    When to specify chrome‑moly steel (F11/F22) for feed effluent exchangers:
    ConditionRecommended Material
    Temperature < 350°C, H₂ partial pressure < 1 MPaCarbon steel (SA516) – limited application
    Temperature 350‑450°C, H₂ partial pressure 1‑5 MPaF11 (1.25Cr‑0.5Mo)
    Temperature 400‑500°C, H₂ partial pressure > 5 MPaF22 (2.25Cr‑1Mo) or higher alloy
    Temperature > 480°CF91 or stainless steel / alloy
    Advantages of Ordering Hydrocracking Heat Exchangers from Yuhong Group
    • Proven experience: Successfully delivered feed effluent exchangers (including 801CB as shown) for hydrocracking units.

    • Full engineering: Thermal design, mechanical design, and detailed fabrication – all in‑house.

    • Material expertise: Chrome‑moly steels, stainless steel clad plate, and nickel alloys – selection guided by API 941 and ASME Section VIII.

    • Complete documentation: Design reports, material certifications, NDE reports, and ASME data reports.

    • Project management: From order to delivery – including third‑party inspection (SGS, BV, TÜV).

    Component‑Only Supply – We Also Provide for Maintenance & Spares

    If your existing exchanger needs replacement parts, we supply individual components without ordering a complete new exchanger:

    • U‑bend tube bundles – direct replacement for existing shells

    • Heat exchanger tubes – chrome‑moly (F11/F22), stainless steel (304/316L), nickel alloy – cut to length, bent, and end‑prepared

    • Heat exchanger tubesheet – drilled and grooved, with or without weld overlay

    • Baffles, tie rods, spacers – machined to your pattern

    • Channel covers, flanges – any facing type

    • Fin tubes – for air cooler retrofits

    Typical Industries & Applications
    IndustryApplicationMaterial Selection
    Petroleum refining (hydrocracking)Feed/effluent exchangers – as shownF11/F22 with stainless overlay
    HydrotreatingReactor feed/effluent exchangersF11/F22 or stainless steel
    Chemical processingHigh‑temperature synthesis exchangersChrome‑moly or stainless
    Power generationHigh‑pressure steam generatorsF22 or F91
    Project Case: Feed Effluent Exchanger 801CB (as shown in photographs)
    ParameterDetail
    ProjectHydrocracking unit feed effluent exchanger
    Unit tag801CB
    Design typeU‑tube (typical for this service)
    MaterialChrome‑molybdenum steel (F11/F22) with stainless overlay
    ServiceHigh‑temperature, high‑pressure hydrogen service
    ComplianceASME U‑Stamp, API 941
    StatusSuccessfully fabricated and delivered
    Quality Assurance & Documentation

    Every hydrocracking feed effluent exchanger we fabricate includes:

    • ASME U‑Stamp certification – design, materials, fabrication, and inspection

    • Material Test Certificates (MTC) per EN 10204 3.1 for all pressure‑retaining components

    • NDE reports – RT, UT, MT, PT as required by ASME

    • Heat treatment records – stress relief and PWHT (post‑weld heat treatment)

    • Hydrostatic test report – shell side and tube side

    • Positive Material Identification (PMI) – 100% verification

    • Third‑party inspection (SGS, BV, TÜV) – available at buyer's request

    Get a Quotation for Your Hydrocracking Feed Effluent Exchanger

    To quote a high‑pressure feed effluent exchanger like the one in your photographs, send the following to [email protected]:

    • Process data sheet (flow rates, inlet/outlet temperatures, pressures)

    • Fluid composition (hydrogen content, H₂S, ammonia, etc.)

    • Project specifications (if available)

    • Required code compliance (ASME, API, etc.)

    Our engineers will respond with a technical proposal, general arrangement drawing, and competitive price – typically within 72 hours.

    Quality High Pressure Feed Effluent Heat Exchanger for Hydrocracking for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: YUHONG HOLDING GROUP CO., LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more TEMA Heat Exchanger products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0