    Compact Nanoparticle Size & Zeta Potential Analyzer

    Nanoparticle Size & Zeta Potential Analyzer
    Product Overview

    The NKT‑N9 series nanoparticle size analyzers are specifically designed for the characterization of nanoparticle size and size distribution. Based on the principles of Dynamic Light Scattering (DLS) and Photon Correlation Spectroscopy (PCS) technology, the instrument uses a laser to illuminate nanoparticles uniformly dispersed in a sample cell.

    The detection fiber receives, at a 90° angle, the dynamic scattered light whose intensity fluctuates over time due to the Brownian motion of the sample particles. This light is transmitted to a photomultiplier tube (PMT), which converts the optical signals into discrete pulse signals. A digital correlator then performs autocorrelation calculations to obtain the autocorrelation curve of the sample. Combined with mathematical methods, the diffusion coefficient of the particles is derived, and finally the particle size and size distribution are calculated according to the Stokes‑Einstein equation.

    Scope of Application

    The NKT‑N9 laser particle size analyzer is widely used for particle size characterization as well as dispersion stability and system stability analysis of organic or inorganic nano‑emulsions, powders, polymers, micelles, virus antibodies, proteins, and other samples in fields such as:

    • New materials
    • Medicinal products
    • Bioengineering
    • Life sciences
    • Chemical engineering
    • Coatings
    • Food safety
    Product Parameters
    ParameterSpecification
    Measurement PrincipleDynamic Light Scattering (DLS), Photon Correlation Spectroscopy (PCS), Static Light Scattering (SLS)
    Particle Size Range0.5 nm – 10,000 nm (depending on sample options)
    Detection Angle90°
    Test ParametersParticle size, molecular weight, second virial coefficient
    LaserIntegrated temperature control system, max power 50 mW, wavelength 532 nm or 405 nm solid-state laser (optional)
    Correlator512 physical channels, sampling time dynamically adjustable from 0.1 µs to 1 ms
    DetectorPhotomultiplier Tube (PMT)
    Filtering MethodOptical trap filtering
    Accuracy ErrorBetter than ±1% (average particle size, NIST traceable reference material)
    Repeatability ErrorBetter than ±1% (average particle size, NIST traceable reference material)
    Sample Cell12 mm quartz cuvette, 1 ml – 4 ml
    Concentration Range0.1 mg/ml – 40 % w/v (depending on sample options)
    Molecular Weight Range340 Da – 2 * 10⁷ Da (depending on sample options)
    Measurement SpeedLess than 5 minutes per run
    Temperature Control Range5 °C – 90 °C
    Temperature Accuracy±0.1 °C
    Intensity Adjustment Range0 – 100%, automatic adjustment
    Environmental Requirements5 °C – 45 °C, 10% – 85% relative humidity (non‑condensing)
    Power SupplyAC100 V – 240 V @ 50 Hz – 60 Hz, DC12 V/10 A
    Dimensions440 mm * 245 mm * 228 mm
    Instrument Weight9.5 kg
    Applicable StandardsGB/T 29022‑2021 / ISO 22412‑2017, GB/T 19627‑2005 / ISO 13320‑1996
    Model Comparison
    FeatureNKT‑N9NKT‑N9H
    Light SourceFiber‑coupled semiconductor laserFiber‑coupled semiconductor laser
    Wavelengthλ = 520 nmWavelength 1: λ = 520 nm, P = 30 mW
    Wavelength 2: λ = 405 nm, P = 20 mW
    PowerP = 30 mW
    ApplicationsSuitable for most nanoparticle tests, but cannot effectively test light‑absorbing samples (e.g., red samples)Suitable for effective testing of all nanoparticles, especially colored samples in industries such as dyes and pigments, enabling effective particle size testing for full‑color‑range samples
    Technical Features
    All‑Fiber Test Optical Path – High Sensitivity

    The test optical path, constructed with a high‑performance, low‑noise fiber‑coupled semiconductor laser and an all‑fiber dynamic scattered light receiving system, uses a low dark count, high‑sensitivity HAMAMASTU photomultiplier tube (PMT) as the photodetector. This gives the entire test system extremely high sensitivity and signal‑to‑noise ratio, laying the foundation for test accuracy and high resolution.

    High‑Speed Digital Correlator – High Resolution

    The independently developed high‑speed digital correlator is used as the core device for signal processing. It acquires dynamic scattered light intensity in real time at high speed and performs autocorrelation calculations. It features a signal resolution capability of 6 ns, a data processing speed of hundreds of megahertz, and a linear dynamic range greater than 10¹¹, ensuring the integrity of autocorrelation curves for particles of different sizes across the full measurement range.

    Full‑Range Calibration and Validation – Ensuring Test Accuracy

    Multiple national particle size reference materials are used for calibration and validation across the full measurement range, with test accuracy errors all below 1 %.

    High‑Precision Temperature Control

    The semiconductor laser, equipped with automatic temperature control technology, ensures stable and reliable laser output. The high‑precision temperature control system keeps the tested sample in the sample cell at a constant temperature throughout the measurement process, avoiding test deviations caused by changes in medium viscosity and particle Brownian motion velocity due to temperature variations, thereby ensuring reliable and stable test results.

    One‑Click Dual Wavelength Switching – Wider Applicability

    Using dual‑wavelength (λ1 = 520 nm, λ2 = 405 nm) fiber‑coupled semiconductor lasers as the light source overcomes the limitation that a single‑wavelength laser cannot test light‑absorbing samples, enabling effective particle size testing for full‑color‑range samples. One‑click switching between the two wavelengths makes the instrument applicable to a wider range of samples.

    For further information or to discuss your specific requirements, please contact us directly.
    Quality Compact Nanoparticle Size & Zeta Potential Analyzer for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Shaanxi KeGu New Material Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Industrial Equipment products from this supplier
    Inquiry Cart 0