Sign In | Join Free | My himfr.com
Home > Level Measuring Instruments >

Stable Performance Vortex Flow Transmitter DN100 RS485 Output ±1.0% Accuracy

    Buy cheap Stable Performance Vortex Flow Transmitter DN100 RS485 Output ±1.0%  Accuracy from wholesalers
     
    Buy cheap Stable Performance Vortex Flow Transmitter DN100 RS485 Output ±1.0%  Accuracy from wholesalers
    • Buy cheap Stable Performance Vortex Flow Transmitter DN100 RS485 Output ±1.0%  Accuracy from wholesalers
    • Buy cheap Stable Performance Vortex Flow Transmitter DN100 RS485 Output ±1.0%  Accuracy from wholesalers

    Stable Performance Vortex Flow Transmitter DN100 RS485 Output ±1.0% Accuracy

    Ask Lasest Price
    Brand Name :
    Model Number : LUGBML
    Price : Negotiation
    Payment Terms : T/T
    Supply Ability : 500pcs per month
    Delivery Time : 7-10 working days
    • Product Details
    • Company Profile

    Stable Performance Vortex Flow Transmitter DN100 RS485 Output ±1.0% Accuracy

    Vortex Flow Meter DN100 Made in China with RS485 Output


    1. Introduction

    LUGBML is based on vonkarman's vortex principle and uses piezoelectric crystals as the test element. It is a new type of stress detection vortex flowmeter. It has the advantages of large turndown ratio, high accuracy, small pressure loss, good medium versatility, pulse output proportional to flow rate, and convenient connection with computer. Because the sensor's detection probe and eddy current generator are installed separately, the high temperature resistant piezoelectric crystal is not The contacting instrument has simple structure, good versatility and high stability. LUGBML series vortex flowmeter sensors can be used to detect and measure the flow of various gases, liquids and steam. It can be used with our company's ML6000 series vortex flowmeter. It can also cooperate with a computer and temperature, pressure, and density sensors to form a high-precision mass flow or heat flow detection system.


    2. Features

    • The vortex flowmeter has a simple and firm structure, no moving parts, and good stability.
    • Simple installation and convenient maintenance.
    • The measurement range is wide, the ratio is as high as 10:1.
    • Compensate the liquid volume as required, and there is no need to recalibrate the meter coefficient after replacing the accessories.

    3. Specifications

    1) Measuring medium: Steam,gas, liquid(Avoid of multiple- direction fluid)

    2) Accuracy:Liquid:1.0% Gas:1.5%

    3) Repeatability:Liquid 0.33% Gas:0.5%

    4) Range:Liquid:0.7m/s~7m/s Gas:7m/s~40m/s

    5) Working pressure:Standard 1.6MPa,2.5~4.0 MPa (on request)

    6) Fluid temperature:-40℃~250℃(Common type);100℃~350℃(High-temperature type)

    7) Body material:304 stainless steel(SS316 is optional)

    8) Output signal:Pulse(three wires,low level≤1V;High level≧4V);4~20mA;RS485

    9) Power supply:24VDC(12VDC),Lithium battery

    10) Ambient temperature : -35 ℃ ~ 60 ℃ ( without LCD ); -5℃~60℃(with LCD)

    11) Relative humidity:5~95%

    12) Protection level:IP65

    13) Electrical connection:M20*1.5


    4. Dimensional Sketche

    DNA(mm)B(mm)C(mm)
    256565368
    326665374
    408076382
    508089388
    6593102402
    80100114408
    100126136435
    125146160463
    150166182489
    200196248543
    250210282596
    300240334648

    5. Design & Installation


    The installation of the instrument is very important, if the installation is not good, it will affect the accuracy, service life and damage.


    1. In order to avoid high-power, high-frequency, high-power switch groups, instrument power supplies should be avoided near these devices.


    2. Avoid high temperatures and radiation sources. If installation is required, thermal insulation and ventilation measures should be taken.


    3. In order to avoid high temperature and enchanted gas, ventilation measures should be taken if installation is needed.


    4. The eddy current flowmeter should not be installed in the sloshing part of the pipe. If it must be installed on it, a clamping device and a vibration pad located in 2D should be added to enhance shock resistance. It is best to install the instrument indoors, pay attention to waterproof during outdoor installation, and pay special attention to the joint to make the cable wire U-shaped, so as to prevent water from entering the amplifier body, and enough space should be saved at the installation place for installation and routine maintenance.


    6. Packing

    Quality Stable Performance Vortex Flow Transmitter DN100 RS485 Output ±1.0%  Accuracy for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Vortex Flow Meter products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0