Sign In | Join Free | My himfr.com
Home > Used Hardware >

DC24V / AC220V K23D-3 Pilot Operated Pneumatic Solenoid Coil 17.5mm x 50.5mm x 44mm

    Buy cheap DC24V / AC220V K23D-3 Pilot Operated Pneumatic Solenoid Coil 17.5mm x 50.5mm x 44mm from wholesalers
     
    Buy cheap DC24V / AC220V K23D-3 Pilot Operated Pneumatic Solenoid Coil 17.5mm x 50.5mm x 44mm from wholesalers
    • Buy cheap DC24V / AC220V K23D-3 Pilot Operated Pneumatic Solenoid Coil 17.5mm x 50.5mm x 44mm from wholesalers
    • Buy cheap DC24V / AC220V K23D-3 Pilot Operated Pneumatic Solenoid Coil 17.5mm x 50.5mm x 44mm from wholesalers
    • Buy cheap DC24V / AC220V K23D-3 Pilot Operated Pneumatic Solenoid Coil 17.5mm x 50.5mm x 44mm from wholesalers
    • Buy cheap DC24V / AC220V K23D-3 Pilot Operated Pneumatic Solenoid Coil 17.5mm x 50.5mm x 44mm from wholesalers

    DC24V / AC220V K23D-3 Pilot Operated Pneumatic Solenoid Coil 17.5mm x 50.5mm x 44mm

    Ask Lasest Price
    Brand Name : BRANDO
    Model Number : BB17544509
    Certification : None
    Price : Negotiation
    Payment Terms : T/T, PayPal, Western Union
    Supply Ability : 300000 set per month
    Delivery Time : Negotiation
    • Product Details
    • Company Profile

    DC24V / AC220V K23D-3 Pilot Operated Pneumatic Solenoid Coil 17.5mm x 50.5mm x 44mm

    DC24V / AC220V K23D-3 Pilot Operated Pneumatic Solenoid Coil 17.5mm x 50.5mm x 44mm


    The structure and characteristics of the K23D-3 pilot operated solenoid valve coil, the bobbin body is composed of thermosetting resin, and a core coil winding and a terminal connection extending to one side of the bobbin provides the body of the bobbin. By providing a waterproof rib on the end face of thermosetting resin bobbin, the bobbin and package layer are well combined to form a sealing structure, thus fundamentally solving the problem of outer package layer and package of electromagnetic coil in injection molding. The problem with welding, even if there is condensed water on the surface of the coil, the condensed water cannot penetrate into the coil winding through the waterproof sealing structure rib in alternately heating and cooling the coil during use, so the coil maintains good water resistance and insulation performance.


    Technical parameter of DC24V / AC220V K23D-3 Pilot Solenoid Valve Coils:

    Model numberBB17544509
    Staard voltageDC12V, DC24V, AC110V, AC220V (±10%)
    Normal powerDC: 12Watt, AC: 22VA
    MaterialCopper, Plastic
    Wire classH, B, F
    Connection typeDIN4.8
    ApplicationPilot Operated Pneumatic Solenoid Valve
    Hole size17.5 mm
    Height50.5 mm
    Width44 mm

    Main dimension of K23D-3 Pilot Operated Pneumatic Solenoid Coils:


    Standard stock of K23D series electric magnetic coil for you to choose:


    Automatic Production Display of K23D series electromagnetic coil:


    More details about K23D-3 Solenoid Coil in below Youtube Video:


    How to increase Q value of solenoid valve coil?

    The quality factor Q is a weight parameter reflecting the mass of the coil. Increasing the Q value of the coil is one of the important points to be paid attention to when winding the electromagnetic coil. So, how to improve the Q value of the electromagnetic coil? Let me elaborate as follows:

    Choose the wire of the coil according to the working frequency. Inductors with short working and low frequency are usually fired with insulated wire such as enameled wire. The operating frequency is higher than tens of thousands of Hz. In circuits below 2MHz, multi-strand insulated wires are used to wind electromagnetic coils, which can effectively increase the surface area of the conductor and make the Q value higher than that of single-wire wound coils with the same cross-sectional area. About 30%.


    Use high quality coil bobbins to reduce dielectric losses. In high frequency applications such as short wave, the dielectric loss is very high due to the winding of the ordinary coil. Therefore, high-frequency dielectric materials such as high-frequency ceramics, ptfe, and polystyrene should be used as the framework and wound by winding method.


    Choose a reasonable coil size to minimize damage. When winding thickness T, winding length L and outer diameter D satisfy 3T + 2L = D, the loss is also minimal. Shielded coils are optimal when L/D = 0.8-1.2.


    Choose a reasonable shield diameter. Using a guard increases the damage to the solenoid and reduces the Q value. Therefore, the shield size should not be too small. If the shielding area is too large, the volume will increase.


    Welcome to your any question and inquiry!

    Quality DC24V / AC220V K23D-3 Pilot Operated Pneumatic Solenoid Coil 17.5mm x 50.5mm x 44mm for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Ningbo Brando Hardware Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Solenoid Valve Coil products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0