    Non Standard Purification Vertical AHU Clean Room Air Handling Units

    Ask Lasest Price
    Brand Name : Shenglin
    Model Number : SLZK Series
    Certification : CE
    Price : 5000~10000USD/unit
    Payment Terms : T/T, Western Union
    Supply Ability : 100 Units Per Month
    Delivery Time : 35~40days
    • Product Details
    • Company Profile

    Non Standard Purification Vertical AHU Clean Room Air Handling Units

    Non-standard Customization Purification Air Conditioning Unit For PCR Detection

    Feature: integral design, simple and convenient installation and operation, inverter compressor, dual EC fan, PLC high precision constant temperature and humidity control. Non-standard design.

    Clean operating room air conditioning system solution Ⅰ

    l DC frequency conversion outdoor unit + clean operating room air conditioning unit + PLC intelligent control


    1,Frequency conversion technology: The DC frequency conversion compressor is used to adjust the operating frequency of the compressor according to the temperature change, which is efficient and energy-saving

    2,Low ambient temperature cooling: The outdoor unit adopts EC fan, and the speed of the outdoor fan is controlled by the condensing pressure sensor to achieve -20℃ low temperature cooling operation;

    3,Low temperature air supply: Shenglin's unique technology, through the grading and separate control of the evaporator, reduces the evaporation temperature, and the minimum air supply temperature is 5℃;

    4,Precise temperature control: electric reheating and electric preheating are steplessly adjusted by SCR to accurately control the indoor temperature

    5,Low ring temperature heating: advanced air jet enthalpy technology, normal heating operation at an ambient temperature of -20°C.


    Air conditioning system solution for clean operating room Ⅱ

    l Four-pipe air-cooled heat pump heat recovery unit + clean operating room combined air conditioner + PLC control

    Multi-function: four-pipe, frequency conversion adjustment, cooling and heating operation can realize energy recovery at the same time, no need to add a hot water tank to adjust the water capacity on the hot water side;

    Low-temperature heating: Adopting jet enthalpy and high-temperature liquid injection technology, heating operation at minus 20℃, and energy efficiency ratio higher than 2.1;

    Low temperature refrigeration: EC fan is used to detect the discharge pressure of the compressor to achieve normal refrigeration at -20°C,

    Cooling and heating balance: automatic cooling and heating balance under partial cooling and heating load, automatic distribution of refrigerant flow;

    System stability: Adopting single four-valve design, consistent operation, mature system technology, stable and reliable operation;

    Energy saving and environmental protection: annual heat recovery can be realized, energy recovery can be adjusted, cooling energy efficiency ratio ≥ 4.0, while heat energy efficiency ratio ≥ 5.0, combined cooling and heating energy efficiency ratio ≥ 9.0, operation energy saving effect is more significant ;

    Intelligent control: Microcomputer PLC control technology, automatically detects the operating status, and realizes energy-saving operation;

    Fault self-check: automatic fault detection system can detect operation faults such as suction and exhaust pressure, exhaust temperature, phase loss and reverse phase, overcurrent and overload;

    Unique technology: the perfect combination of single four-way valve design, ultra-low temperature heating design, low temperature refrigeration design, and stable mode conversion.


    Clean operating room air conditioning system solution Ⅲ

    l Air-cooled heat pump + clean operating room combined air conditioning unit + PLC control

    Precise temperature control: DC inverter compressor is used, and the operating power of the compressor is self-matched according to changes in ambient temperature;

    Low ambient temperature refrigeration: The outdoor unit adopts EC fan, and the speed of the outdoor fan is controlled by the condensing pressure sensor to achieve -20℃ low temperature cooling operation;

    Low ring temperature heating: advanced air jet enthalpy technology, normal heating operation at an ambient temperature of -20℃;

    Intelligent defrosting: super-cooling ice suppression technology, combined with Sunlin’s unique defrosting module, with frost defrosting, frost-free heating

    Smart cloud service: PC client + mobile App real-time monitoring.

    Standard AHU model representation method:


    Unit quick selection table (air volume)

    ModelNominal air volume m³/hWindward area of coil㎡Wind speed of the coil(m/s)
    2.002.252.502.753.003.25
    m³/h
    SLZK015W15000.16115212961440158417281872
    SLZK018W18000.2144016201800198021602340
    SLZK022W22000.24172819442160237625922808
    SLZK032W32000.35252028353150346537804095
    SLZK038W38000.42302434023780415845364914
    SLZK050W50000.56403245365040554460486552
    SLZK063W63000.7504056706300693075608190
    SLZK072W72000.8576064807200792086409360
    SLZK095W95001.04748884249360102961123212168
    SLZK120W120001.393601053011700128701404015210
    SLZK150W150001.69121681368915210167311825219773
    SLZK180W180002.08149761684818720205922246424336
    SLZK230W230002.56184322073623040253442764829952
    SLZK270W270003.04218882462427360300963283235568
    SLZK320W320003.61259922924132490357393898842237
    SLZK370W370004.18300963385837620413824514448906
    SLZK430W430004.75342003847542750470255130055575
    SLZK500W500005.5396004455049500544505940064350
    SLZK550W550006.16443524989655440609846652872072
    SLZK630W630007504005670063000693007560081900
    SLZK700W700007.84564486350470560776168467291728
    SLZK760W760008.5612006885076500841509180099450
    SLZK850W850009.5268544771128568094248102816111384
    SLZK930W9300010.36745928391693240102564111888121212
    SLZK1000W10000011.478258492907103230113553123876134199
    SLZK1100W11000012.5890576101898113220124542135864147186

    Note: 1. It is recommended to add a water baffle if the wind speed exceeds 2.75m/s.


    Unit quick selection table (cooling capacity of coil section under return air condition)

    ModelNominal air volume m³/h4 rows6 rows8 rows
    Cooling capacityWater volumeCooling capacityWater volumeCooling capacityWater volume
    kWm³/hkWm³/hkWm³/h
    SLZK015W15008.21.410.91.8713.22.27
    SLZK018W180010.21.813.62.3416.52.84
    SLZK022W220012.62.216.42.8219.83.41
    SLZK032W320017.83.123.84.0928.84.95
    SLZK038W380021.53.728.64.9234.65.95
    SLZK050W500028.74.938.16.5546.27.95
    SLZK063W630035.86.247.88.2257.59.89
    SLZK072W720041.17.154.69.3966.111.37
    SLZK095W950053.39.270.812.1885.614.72
    SLZK120W1200066.711.588.615.24107.118.42
    SLZK150W1500086.614.9115.319.83138.623.84
    SLZK180W18000106.518.3141.824.39170.329.29
    SLZK230W23000131.222.6172.929.74210.536.21
    SLZK270W27000155.826.8206.835.57248.642.76
    SLZK320W32000185.131.8245.242.17296.551.00
    SLZK370W37000214.236.8285.149.04341.858.79
    SLZK430W43000243.341.8323.655.66385.666.32
    SLZK500W50000281.548.4374.564.41450.377.45
    SLZK550W55000315.754.3419.372.12500.486.07
    SLZK630W63000358.661.7476.581.96560.496.39
    SLZK700W70000400.568.9534.191.87640.5110.17
    SLZK760W76000432.674.4578.299.45690.5118.77
    SLZK850W85000482.583.0645.8111.08765.8131.72
    SLZK930W93000520.689.5702.3120.80830.5142.85
    SLZK1000W100000576.199.1778.4133.88940.8161.82
    SLZK1100W110000630.6108.5850.6146.30970.5166.93

    Note:

    1. The inlet temperature of chilled water is 7°C, and the outlet temperature is 12°C;

    2. Return air condition: inlet air dry bulb temperature 27℃, wet bulb temperature 19.5℃;

    3. The above parameters are for reference only. If the working conditions and coil circuit arrangement are changed, the parameters will change.

    Quality Non Standard Purification Vertical AHU Clean Room Air Handling Units for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Shanghai Shenglin M&E Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Clean Room Air Handling Units products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0