Sign In | Join Free | My himfr.com
Home > Other Machinery & Industry Equipment >

S2000 EC9-4 Endocavity Ultrasound Scanner Probe Echo Machine

    Buy cheap S2000 EC9-4 Endocavity Ultrasound Scanner Probe Echo Machine from wholesalers
     
    Buy cheap S2000 EC9-4 Endocavity Ultrasound Scanner Probe Echo Machine from wholesalers
    • Buy cheap S2000 EC9-4 Endocavity Ultrasound Scanner Probe Echo Machine from wholesalers
    • Buy cheap S2000 EC9-4 Endocavity Ultrasound Scanner Probe Echo Machine from wholesalers
    • Buy cheap S2000 EC9-4 Endocavity Ultrasound Scanner Probe Echo Machine from wholesalers

    S2000 EC9-4 Endocavity Ultrasound Scanner Probe Echo Machine

    Ask Lasest Price
    Brand Name : Siemens
    Model Number : EC9-4
    Price : Negotiable
    Payment Terms : T/T, Western Union
    Delivery Time : 1-3 work days
    • Product Details
    • Company Profile

    S2000 EC9-4 Endocavity Ultrasound Scanner Probe Echo Machine


    Siemens S2000 EC9-4 Endocavitary Ultrasound Probe Echo Machine


    Compatible Ultrasound Systems: Acuson NX2, Acuson S300, Acuson S1000, and Acuson S2000
    Bandwidth: 9-4 MHz
    Type of Array: Endocavitary
    Application: OB/GYN, Urology, Prostate




    Knowledge point


    Ultrasonic transducers for medical diagnostic imaging


    Over the past decades, ultrasound imaging technology has made tremendous progress in obtaining important diagnostic information from patients in a rapid, noninvasive manner. Although the technology has benefited from sophisticated signal processing technology and imaging system integration, much of this progress has been derived from the development of ultrasonic transducers that are in direct contact with patients. An overview of medical ultrasonic imaging transducers is presented in this review that describes their structure, types, and application fields. The structural components of a typical transducer are presented in detail including an active layer, acoustic matching layers, a backing block, an acoustic lens, and kerfs. The types of transducers are classified according to the dimensions of ultrasound images: one-dimensional array, mechanical wobbling, and two-dimensional array transducers. Advantages of each transducer over the other and the technical issues for further performance enhancement are described. Application of the transducers to various clinical imaging fields is also reviewed.



    Other Siemens probes we can offer:


    BrandModelCompatible System
    Siemens3.5C55SG50/X150/X300
    Siemens6C1HDS2000
    Siemens7.5L40AG20/G40
    Siemens7.5L75SG20 and Prima / Adara
    SiemensC7F2Antares/ X300 and X500
    SiemensCH4-1Antares
    SiemensCH5-2G40/G60/X150/X300
    SiemensCH6-2Antares
    SiemensCX5-2Antares/ Sonoline Elegra
    SiemensC6-2CV70/ G50/G60/ X300/X500
    SiemensC6F3G50/G60
    SiemensC5F1Antares
    SiemensC8-5X300
    SiemensP10-4Antares
    SiemensPH4-1Antares
    SiemensP4-2G50/G60/CV70/X150/X300/X500
    SiemensP5-1X300, X300PE
    SiemensEC9-4G40/ X150/ X300/Antares
    SiemensEV9F4X300 and Antares
    SiemensVFX9-4Antares
    SiemensVF13-5spAntares/X300/X500/G50/G60
    SiemensVFX13-5Antares
    SiemensVF13-5X150/X300/X500/G40 /G50/G60/ Sonoline Sienna/Sonoline Elegra
    SiemensVF13-5Antares
    SiemensVF10-5Antares
    Siemens4V1CSequoia 512 GI, Sequoia C512, S2000
    Siemens/Acuson4V1Sequoia
    Siemens/Acuson6L3Acuson Sequoia
    Siemens/Acuson8C4Sequoia 512 G /Sequoia C512
    Siemens/Acuson8L5Sequoia 512
    Siemens/Acuson8V5Sequoia
    Siemens/Acuson7L3Cypress
    Siemens/Acuson8V3Sequoia 512 /S1000
    Siemens/Acuson9EVF4S1000/ S2000 and S3000
    Siemens/Acuson9L4Acuson S2000/ Sequoia/Sequoia C512
    Siemens/Acuson10V4Sequoia
    Siemens/Acuson15L8WSequoia 512
    Siemens/Acuson15L8Sequoia
    Siemens/Acuson17L5HDSequoia 512
    Siemens/Acuson18L6HDS1000, S2000, S3000
    Siemens/AcusonAUX CWCypress / Cypress CV System
    Siemens/AcusonC3Aspen
    Siemens/AcusonEC9-4G40/ G60/X150/ X300
    Siemens/AcusonEC7Aspen/ XP128
    Siemens/AcusonEV-8C4Sequoia 512/ S2000
    Siemens/AcusonEC-10C5Sequoia 512
    Siemens/AcusonL5Aspen
    Siemens/AcusonL7Aspen/128XP-10
    Siemens/AcusonTE-V5MSequoia/ Sequoia C512/Sequoia 512/ Aspen/ Cypress/S1000/S2000
    Siemens/AcusonTE-V5MsCypress/Sequoia/S2000/X300 systems
    Siemens/AcusonV4Aspen/ XP
    Siemens/AcusonV7Aspen/ XP


    Common ultrasonic Probe Damage(Convex, Linear, Sector, Endocavity probes)


    Common ultrasonic probe damageSolutions
    Lens damage, wear, holes, swelling, delaminationLens replacement
    Strain relief damage, separationStrain replacement
    Nosepiece and probe separation and cracksStrain replacement
    Cable cutsCable patches, possible cable replacement
    Connector housing electrical damageMajor and minor electrical repairs, pin module replacement

    Quality S2000 EC9-4 Endocavity Ultrasound Scanner Probe Echo Machine for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Guangzhou Rongtao Medical Tech LTD.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Ultrasound Scanner Probe products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0