    Brand Name : GINRI
    Model Number : JVR1000
    Certification : CE,CCC
    Payment Terms : L/C, T/T, Western Union,Paypal
    Supply Ability : 20000Pcs per month
    Delivery Time : 1-30 days upon order quantity
    • Product Details
    • Company Profile

    Elevator part Three Phase Voltage Monitoring Relay phase failure protective deivce 380VAC Din rail

    Elevator part Three Phase Voltage Monitoring Relay phase failure protective deivce


    Phase sequence protector principle
    Phase Sequence Protector Principle Under normal circumstances, the wiring order of the motor work is regulated. If for some reason, the phase sequence is disordered, the motor will not work properly or even be damaged. Phase sequence protection is to prevent such accidents from happening.


    Phase sequence protection can use phase sequence When the phase sequence in the circuit does not match the specified phase sequence, the phase sequence relay will trigger the action and cut off the control circuit so as to cut off the motor power supply and protect the motor.


    Three-phase alternating current phase sequence detection circuit is composed of helium bubble NB. Due to the phase-shifting effect of C1, when the power supply is connected in the phase sequence of A, B, and C in the figure, the helium bubbles emit light, and when the reverse phase sequence is connected to A, C, and B, the helium bubbles are not bright. When the start button QA is pressed, the alternating current is depressurized by C2, VD1, and rectified and DW to obtain a DC voltage of 12V, which is added to the protection execution circuit composed of the relay K and the photosensitive resistor tube V. If the order of the phases is A, B, and C, then the helium bubbles emit light, and the CDS packaged with the helium bubbles exhibits a very low impedance after being irradiated with light, and then V gets a biased base current and conducts. K picks up, K1 Connect the AC control circuit, C pulls in and the motor starts running. On the other hand, if the reverse phase sequence is followed, the bubble does not light, K does not pull, and K1 turns off, and the motor cannot be started. This achieves the purpose of protection.


    ♦ Features

    -- Built-in LCD and keypad afford a precise,digital setting

    -- Three-phase monitoring of phase sequence, phase loss, over- and undervoltage and phase unbalance

    -- Adjustable over- and undervoltage, phase unbalance threshold

    -- Independent adjustable delay time for overvoltage, undervoltage, phase unbalance

    -- Powered by the measuring circuit

    -- 1 NO & 1NC contacts

    -- Faulure recording


    ♦ Protective Functions

    -- Phase sequence

    -- Phase loss

    -- Phase unbalance

    -- Overvoltage

    -- Undervoltage


    ♦ Typical Applications

    • Pumps • Fans

    • Blowers • Motors

    • Compressors


    ♦ Approvals

    • CE • CCC


    ♦ Technical data


    TypeJVR1000
    Measuring circuitL1,L2,L3
    Rated voltage380VAC ,50Hz
    Monitoring functionsphase sequence, phase loss, overvolatege, undervoltage,phase unbalance
    Overvoltage setting range390-490V adjustable
    Undervoltage setting range300-470V adjustable
    Hysteresis10V
    Delay time for overvoltage and undervoltage0.1-25s adjustable
    Phase unbalance setting range5%-29% adjustable
    Delay time for phase unbalance1-25s adjustable
    Delay time for phase loss1s
    Delay time for phase sequenceinstant
    IndicatorsLCD indicating voltage,current,operation status
    Output contacts1 NO,1NC
    Contact capacity6A ,250VAC
    Dimensions (H x W x D)80×40×54mm
    MountingDIN rail

    Quality Elevator part Three Phase Voltage Monitoring Relay phase failure protective deivce 380VAC Din rail for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Wenzhou Ginri Power Automation Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Three Phase Voltage Monitoring Relay products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0