Dismountable Open Loop Hall Effect Current Sensor TKC-EKA 100A to 500A ±15V

TKC-EKA series dismountable open loop Hall effect current sensor measures DC, AC, or pulsed currents with galvanic isolation. Rated ±100A to ±500A, ±15V supply, response time ≤5μs. UL94-V0 certified, custom input/output available. Ideal for drives, UPS, welding.

Price: Price Reconsideration MOQ: 10pcs Delivery Time: Negotiable

4800A Open Loop Hall Effect Current Sensor TKC-GT1540 for Inverter DC AC Pulse

Measures up to 4800A DC with ±750A rated input. Open loop Hall effect design ensures galvanic isolation and fast 6μs response. Suitable for variable speed drives, UPS, and welding. UL94-V0 certified with customizable output.

Price: Price reconsideration MOQ: 10pcs Delivery Time: 7~10 working days

TKC-BS/BR Open Loop Hall Effect Current Sensor 50A to 600A Pulsed Current Measurement

Accurate open loop Hall effect sensor for DC, AC, or pulsed currents. Rated input ±50A to ±600A with ±4V output. Features galvanic isolation, fast response ≤3μS, and low offset drift. UL94-V0 certified. Custom options available.

Price: Price reconsideration MOQ: 10pcs Delivery Time: 7~10 working days

Hall Effect Current Sensor Transducer 1000-20000A Open Loop for Frequency Converter

Open loop Hall effect current sensor for DC, AC or pulsed currents. Rated 1000-20000A with 6KV galvanic isolation. Features ±15V supply, ≤1%FS linearity, and ≤10μS response time. Ideal for variable speed drives, UPS, and welding machines. UL94-V0 certified.

Price: Price reconsideration MOQ: 10pcs Delivery Time: 7~10 working days

UL94-V0 Open Loop Hall Effect Current Sensor 100-2000A Input Current ±15V Supply

Accurate open loop Hall effect sensor for DC, AC or pulsed currents from 100 to 2000A. Features galvanic isolation, fast response ≤5μs, and UL94-V0 certification. Custom input/output options available for industrial applications.

Price: Price reconsideration MOQ: 10pcs Delivery Time: 7~10 working days

Open Loop Hall Effect Current Transformer 20-500A ±5V Supply Programming Type

Accurate open loop Hall effect current sensor for DC, AC or pulsed currents. Rated 20-500A with ±5V supply, 2.5KV isolation, and ≤8μS response. UL94-V0 certified. Ideal for variable speed drives, UPS, and welding machines.

Price: Price reconsideration MOQ: 10pcs Delivery Time: 7~10 working days

Blue AC DC Open Loop Hall Effect Current Sensor 50-300A for UPS Systems

Accurate open loop Hall effect sensor for DC, AC or pulsed currents. Rated input ±50 to ±300A, ±15V supply, 2.5KV isolation. UL94-V0, EN60947 compliant. Custom output and input ranges available.

Price: Price reconsideration MOQ: 10pcs Delivery Time: 7~10 working days

BMS 22mm Aperture 800A Hall Effect Current Sensor Open Loop DC AC

Open loop hall effect current sensor for BMS and EV applications. Measures ±800A with ±5V supply, 2.5kV isolation, ≤3μS response time. UL94-V0 certified. Custom input/output options available.

Price: Price reconsideration MOQ: 10pcs Delivery Time: 7~10 working days

3 Phase DC AC Pulsed Open Loop Hall Effect Current Sensor 50-200A

Accurate open loop Hall effect sensor for 3 phase DC, AC or pulsed currents. Rated 50-200A with ±15V supply. Features galvanic isolation, ≤5μS response time, and UL94-V0 compliance. Ideal for variable speed drives and UPS.

Price: Price reconsideration MOQ: 10pcs Delivery Time: 7~10 working days

Dismountable Hall Effect Current Transformer 400A to 3000A DC AC Pulse Measurement

Open-loop Hall effect sensor measures DC, AC, and pulse currents up to 3000A with electrical isolation. Features ±15V supply, 6KV isolation, and ≤7μS response time. UL94-V0 certified, customizable input/output. Ideal for UPS, welding, and variable speed drives.

Price: Price reconsideration MOQ: 10pcs Delivery Time: 7~10 working days

Blue Hall Effect Current Sensor Transducer TKC-BSR565 50A to 600A Open Loop DC AC

Open loop Hall effect current sensor for accurate DC, AC or pulsed current measurement. Features galvanic isolation, ±5V supply, 2.5KV isolation, and linearity ≤1%FS. Custom input ranges available. UL94-V0 certified.

Price: Price reconsideration MOQ: 10pcs Delivery Time: 7~10 working days

100-2000A Open Loop Hall Effect Current Sensor ±1% Accuracy DC AC Pulse

TKC-BHS5 series open loop Hall effect sensor offers ±1% accuracy for DC, AC, and pulse current measurement from 100 to 2000A. Features galvanic isolation, low offset drift, and fast response. Ideal for UPS, SMPS, and variable speed drives. Custom options available.

Price: Price reconsideration MOQ: 10pcs Delivery Time: 7~10 working days

TKC-BR Series Open Loop Hall Effect Current Sensor 50A to 600A ±15V DC

High sensitivity non-contact current sensor for DC, AC, or pulsed currents. Features galvanic isolation, ±1% linearity, and ≤3µS response time. UL94-V0 certified with customizable output. Ideal for UPS, SMPS, and variable speed drives.

Price: Price reconsideration MOQ: 10pcs Delivery Time: 7~10 working days

Open Loop Hall Effect Current Sensor DC 500V 1000MΩ Accuracy ±1% 500A to 5000A

TKC-HAX series open loop Hall effect current sensor measures DC, AC or pulsed currents with ±1% accuracy. Features galvanic isolation up to 5KV, wide bandwidth DC to 25KHz, and fast response ≤5μS. Customizable input ranges from 500A to 5000A. Ideal for UPS, welding, and variable speed drives.

Price: Price reconsideration MOQ: 10pcs Delivery Time: 7~10 working days

Hall Effect Based Current Sensor TKC-H 600A to 3000A Open Loop DC AC Pulsed

TKC-H series open loop Hall effect current sensor measures DC, AC, or pulsed currents with galvanic isolation. Rated current from ±600A to ±3000A, response time ≤7μs, and 6KV isolation. UL94-V0 certified, customizable output. Ideal for drives, UPS, and welding.

Price: Price reconsideration MOQ: 10pcs Delivery Time: 7~10 working days

Non Contact Hall Effect DC Current Sensor 200A to 1500A Open Loop

Open loop Hall effect sensor for accurate DC, AC or pulsed current measurement. Features galvanic isolation, ±15V supply, 3KV isolation, and ≤5μS response time. Customizable output and rated input available. Ideal for UPS, welding, and variable speed drives.

Price: Price reconsideration MOQ: 10pcs Delivery Time: 7~10 working days

1500A Open Loop Hall Effect Current Sensor DC AC Non Contact Measurement ±15V

Non-contact Hall effect current sensor for DC, AC, or pulsed currents. Rated 1500A with ±3000A range. Features galvanic isolation, ±15V supply, ≤5μS response, and UL94-V0 compliance. Custom output available.

Price: Price reconsideration MOQ: 10pcs Delivery Time: 7~10 working days

Open Loop Hall Effect Current Sensor TKC Series 50A to 600A High Sensitivity

High sensitivity open loop Hall effect current sensor for DC, AC, and pulse signals. Rated input ±50 to ±600A with ±15V supply. Features galvanic isolation 2.5KV, fast response ≤3μS, and low offset drift. UL94-V0 certified. Custom output voltage available.

Price: Price reconsideration MOQ: 10pcs Delivery Time: 7~10 working days

IEC60950 Open Loop Hall Effect Current Sensor 600A to 3000A High Accuracy for SMPS

Open loop Hall effect sensor for DC/AC/pulsed current measurement with galvanic isolation. Rated current 600-3000A, response time ≤7μS, linearity ≤1%FS. Compliant with IEC60950, UL94-V0. Custom output options available for UPS, drives, and welding.

Price: Price reconsideration MOQ: 10pcs Delivery Time: 7~10 working days

Open Loop Hall Effect Current Sensor 1000-20000A for Frequency Converter AC Measurement

Non-contact open loop hall sensor for AC/DC current measurement from 1000A to 20000A. Features galvanic isolation, ±15V supply, fast response ≤10μs, and high linearity ≤1%FS. Ideal for variable speed drives, UPS, and welding machines. UL94-V0 certified.

Price: Price reconsideration MOQ: 10pcs Delivery Time: 7~10 working days
1 2