Sign In | Join Free | My himfr.com |
|
... Clip on current transformer Current transformer clamp Current transformer Technial index notes Testing current: 100mA to 6, 000A Accuracy class is divided into 0.1, 0.2, 0.5 and 1.0 grade Primary current: 1...
... Clip on current transformer Current transformer clamp Current transformer Technial index notes Testing current: 100mA to 6, 000A Accuracy class is divided into 0.1, 0.2, 0.5 and 1.0 grade Primary current: 1...
...Current Transformer wide current range 200A ratio 1:1 KE6323-200 Isolation current transformer KE6323-200 Isolation current transformer (ICT) is used for the test of I-P close link meter. When test the three...
... as control centers or load centers, to measure or monitor wattage.These CT can be mounted without removing existing cables for easier installation Features: Test range: 0A - 1000A AC input, output of 0.333V...
... as control centers or load centers, to measure or monitor wattage.These CT can be mounted without removing existing cables for easier installation Features: Test range: 0A - 1000A AC input, output of 0.333V...
...Current Transformer with Current Range 100mA to 3000A Single-phase Current Test SCTK691/2 series retro-fit (split-core) current transformer has been specially designed to facilitate their installation in new...
...Current Transformer Tester Application: Tests for current transformer: Excitation curve and parameters test Turns ratio test Ratio and phase error test Polarity mark check Winding resistance measurement Seco...
...Testing Equipment for Current and Voltage Transformer Test Testing for current transformer equipment: 1 Excitation curve and parameters test 2 Turns ratio test 3 Ratio and phase error test 4 Polarity mark ch...
... phase to three phase. With wide current range, it is perfect for the test of I-P close link meter. Features: High accuracy through active electronic error compensation. Direct perforated installation Wide c...
...Current Transformer For I-P Close Link Meter Testing Ratio 1:1 KE632x-200 Isolation Current Transformer KE632 series Isolation Current Transformer is used on multi-position test benches for testing single ph...
... voltage value The series of current transformer can be applied to test, control, display and record the running of the electrical equipment, and to protect the equipment against the damage, in the AC circui...
...Current Transformer Testing Equipment Introduction: CPT-III Power Current Transformer Testing Equipment is used to measure all kinds of current transformer and voltage transformer. CPT-III Power Current Tran...
...Current Transformer and Voltage Potential Transformer Testing Equipment Introduction: CPT-III Current Transformer and Voltage Potential Transformer Testing Equipment is used to measure all kinds of current t...
... and voltage are closed links, which you need to isolate them. As for the multi-position power meter auto-calibration system, it should add the three phase isolated current transformer: HS-9503. At present, ...
...Current Transformer Calibration Device With Turn Ratio 5000/1 To 25000/5A GF106T Portable Instrument Current Transformer calibration Device with turn ratio 5000/1 to 25000/5A GF106T Portable Instrument Curre...
...test report Proved 12kV MV CT Current Transformer for Air Insulation Switchgear We are manufacturer for instrument transformer CE Proved 12kV MV Current Transformer for Air Insulation Switchgear 12kV indoor ...
... link meter Features: By active electronic error compensation, it can achieve high accuracy through. Install directly through hole Wide current range on primary side and secondaries side: 10mA --120A Output ...
...Current Transformer Testing Equipment Introduction: CPT-III Current Transformer Tester is used to measure all kinds of current transformer and voltage transformer. CPT-III Current Transformer Tester can calc...
..., versatility, and low phase shift to theprobe for a good selection of application range of power measurement widely. Current clamp is portable AC current measuring device and the one-hand operating solution...
... transformer and voltage transformer at rated burden and working burden in one time test. CPT-I Current Transformer Tester can automatically evaluate the test results according to the selected standard to de...