China Ct Current Transformer Electrical Test Set , Touch Screen Ct Testing Equipment for sale
China Ct Current Transformer Electrical Test Set , Touch Screen Ct Testing Equipment for sale

Ct Current Transformer Electrical Test Set , Touch Screen Ct Testing Equipment

CT Tester CT Analyzer CT Testing Equipment Electrical CT Test Set Tester for current transformer: 1.Excitation curve and parameters test 2.Turns ratio test 3. Ratio and phase error test 4. Polarity mark check 5. Coil resistance measurement 6. Secondary loop burden measurement 7. Error line curve test for protection CT 8. Transient CT parameters test 9. CT nameplate guess 10.Saturation hysteresis loop curve measurement Applications of CT Current Transformer Tester: 1 CT

Place of Origin China
Warranty 1 Year
Keyword CT Current Transformer Tester
Size 485mm×356mm×183mm
Packaging Details Plywood case
Test standard IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
Product Description

CT Tester CT Analyzer CT Testing Equipment Electrical CT Test Set

 

 

Tester for current transformer:

1.Excitation curve and parameters test
2.Turns ratio test
3. Ratio and phase error test
4. Polarity mark check
5. Coil resistance measurement
6. Secondary loop burden measurement
7. Error line curve test for protection CT
8. Transient CT parameters test
9. CT nameplate guess
10.Saturation hysteresis loop curve measurement

 

Applications of CT Current Transformer Tester:

1 CT nameplate check
2 CT parameters check in work burden
3 CT transient parameters analysis

4 CT ratio and phase error calibration

 

Specifications:

Item Name CT Current Transformer Tester
Test standards IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
Power supply AC220V±10%, 50/60Hz±10%
Voltage output 0.1~125V (AC)
Current output 0.001~5A(RMS)
Power output 300VA
Max. knee voltage measurement 45KV
Current measurement
 
Range 0~10A (automatically change range in 0.1/0.4/2/10A)
Error <±0.1%+0.01%FS

 

Voltage measurement Range 0~200V (automatically change range in 1V/10V/70V/200V)
Error < ±0.1%+0.01%FS
Turns ratio measurement Range 1~35000
1~2000, error<0.05%
2000~5000,error<0.1%
5000~35000,error<0.2%
Phase measurement error ±2min
resolution 0.01min
Coil resistance measurement Range 0~80Ω (automatically change range in 2ohm/20ohm/80ohm)
Error < 0.2%RDG+0.02%FS
Maximum resolution : 0.1mΩ
Temperature measurement -50~100 Celsius degree; error<3 Celsius degree
CT Secondary burden Range 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
Error <0.2%RDG+0.02%FS
Maximum resolution : 0.001ohm
Memory capacity >1000 groups test results
Working condition temperature -10℃~50℃; moist ≤90%

 