Home Products Fire Detection Tube

Fire Detection Tube

Showing 91 Products

CO2 Fire Extinguisher for Fire Detected Tube Extinguisher Factory direct quality assurance best price

42kg CO2 Fire Extinguisher for Fire Detected Tube Extinguisher Description: This device can detect fire situation by a pressurized fire trace tube, which connecting to an extinguishing agent storage. Both HFC-227ea/FM200 or Carbon Dioxide can be used as extinguishing agent for this device. Usually, it would be designed to two modes of discharge----direct release and indirect release. When fire breaks out, the fire trace will activate the device, and spray extinguishing agent

Price: negotiation MOQ: 10 sets Delivery Time: 10-15 days

3Kg Fm200 Fire Extinguisher Tube With GB25972-2010 Standard

3Kg Fm200 Fire Extinguisher Tube With GB25972-2010 Standard Parameter: No. Specification Technical parameter 1 Type Fm200 direct type 2 model WZ-Q/T-QZ3-XJ60 3 Working pressure 2.5Mpa 4 Max working pressure 4.2Mpa 5 Working temperature 0-50℃ 6 Density of unit volume 0.7kg/m3 7 Max length of detecting tube 20m 8 Quantity of agent 3kg Description: Direct Type Fire Detecting Extinguisher With 3kg Agent is filled with fm200 agent . It is a kind of colorless and tasteless and non

Price: negotiation MOQ: 5 sets Delivery Time: 10-15 working days after payment or receipt of L/C

Automatic CO2/FM200 Direct Type Fire Detection Tube for Class A Fires

Automatic / Hand - Actuated Fire Detection Tube For Different Type Of Fire Parameter: No. Specification Technical parameter 1 Type Carbon dioxide direct type 2 model WZ-Q/T-EZ6-XJ60 3 Working pressure 5.7Mpa 4 Max working pressure 12.1Mpa 5 Working temperature 0-49℃ 6 Density of unit volume 2.5kg/m3 7 Max length of detecting tube 25m 8 Quantity of agent 6kg Description: A fire detection and suppression device that uses a flexible tube filled with a fire suppressant substance

Price: negotiation MOQ: 5 sets Delivery Time: 10-15 working days after payment or receipt of L/C

Indirect Or Direct Type Standard Fm200 Fire Suppression System For Equipment Cabinet

Indirect Or Direct Type Standard Qualify Fm200 Fire Suppression System For Equipment Cabinet Description Fm200 fire trace suppression system is a kind of easy and highly dependable fire suppression system. This system is a little bit different from other fm200 fire suppression systems because it doesn’t need those electrical elements to help it be a complete system. There is a warning device, whose function is equal to the electrical elements, on the top of the fire trace

Price: negotiable MOQ: 5 sets Delivery Time: 10-15 working days after payment or receipt of L/C

Clean And Pure FM200 Fire Trace Suppression System / HFC-227ea Fire Trace Extinguisher

Clean And Pure FM200 Fire Trace Suppression System / HFC-227ea Fire Trace Extinguisher Parameter: No. Specification Technical parameter 1 Type Fm200 direct type 2 model WZ-Q/T-QZ3-XJ60 3 Working pressure 2.5Mpa 4 Max working pressure 4.2Mpa 5 Working temperature 0-50℃ 6 Density of unit volume 0.7kg/m3 7 Max length of detecting tube 20m 8 Quantity of agent 3kg Description: Fire detect tube through the container valve connected to the fire extinguishing agent containers, for

Price: negotiation MOQ: 5 sets Delivery Time: 10-15 working days after payment or receipt of L/C

Co2 Direct Type Fire Extinguisher Tube 12.1Mpa Max Working Pressure

Co2 Direct Type Fire Extinguisher Tube 12.1Mpa Max Working Pressure Parameter: No. Specification Technical parameter 1 Type Carbon dioxide direct type 2 model WZ-Q/T-EZ6-XJ60 3 Working pressure 5.7Mpa 4 Max working pressure 12.1Mpa 5 Working temperature 0-49℃ 6 Density of unit volume 2.5kg/m3 7 Max length of detecting tube 25m 8 Quantity of agent 6kg Description: Co2 Direct Type Fire Detecting Extinguisher is filled with 6kg Co2 and it is automatic starting , through long

Price: negotiation MOQ: 5 sets Delivery Time: 10-15 working days after payment or receipt of L/C

Automatic Carbon Dioxide Fire Extinguisher

6kg Carbon Dioxide Fire Detecting Extinguisher Parameter: No. Specification Technical parameter 1 Type Carbon dioxide direct type 2 model WZ-Q/T-EZ6-XJ60 3 Working pressure 5.7Mpa 4 Max working pressure 12.1Mpa 5 Working temperature 0-49℃ 6 Density of unit volume 2.5kg/m3 7 Max length of detecting tube 25m 8 Quantity of agent 6kg Description: 6kg Carbon Dioxide Fire Detecting Extinguisher is filled with 6kg Co2 . It is a kind of colorless and tasteless gas , it can be used in

Price: negotiation MOQ: 10 sets Delivery Time: 10-15 working days after payment or receipt of L/C

FM200 Fire Detection Tube

3kg Fm200 Fire Detection Tube Parameter: No. Specification Technical parameter 1 Type Fm200 direct type 2 model WZ-Q/T-QZ3-XJ60 3 Working pressure 2.5Mpa 4 Max working pressure 4.2Mpa 5 Working temperature 0-50℃ 6 Density of unit volume 0.7kg/m3 7 Max length of detecting tube 20m 8 Quantity of agent 3kg Description: 3kg Fm200 Fire Detection Tube is an automatic fire extinguishing devices. The agent of this extinguishing system is fm200 , it is a kind of colorless and

Price: negotiation MOQ: 10 sets Delivery Time: 10-15 working days after payment or receipt of L/C

42kg Indirect Fire Detection Tube Quick And Accurate Detection Lightweight Design With Low Maintenance

42kg Carbon Dioxide Indirect Fire Detection Tube For Power Plants Parameter: No. Specification Technical parameter 1 Type Carbon dioxide indirect type 2 model WZ-Q/T-EZ6-XJ60 3 Working pressure 5.7Mpa 4 Max working pressure 12.1Mpa 5 Working temperature 0-49℃ 6 Density of unit volume 2.5kg/m3 7 Max length of detecting tube 25m 8 Quantity of agent 42kg Description: 42kg Indirect Fire Detection Tube With Co2 discharge Co2 gas indirectly . The fire ground pipe and a set of

Price: negotiation MOQ: 5 sets Delivery Time: 10-15 working days after payment or receipt of L/C

Petrochemical Fm200 Fire Detecting Extinguisher 25m 42kg Fire Detection System For Effective Protection

Petrochemical Fm200 Fire Detecting Extinguisher 25m 42kg Fire Detection System Parameter: No. Specification Technical parameter 1 Type Carbon dioxide direct type 2 model WZ-Q/T-EZ6-XJ60 3 Working pressure 5.7Mpa 4 Max working pressure 12.1Mpa 5 Working temperature 0-49℃ 6 Density of unit volume 2.5kg/m3 7 Max length of detecting tube 25m 8 Quantity of agent 42kg Description: Indirect Type Of Fire Detecting Extinguisher With Carbon Dioxide is widely used in power plants,

Price: negotiation MOQ: 5 sets Delivery Time: 10-15 working days after payment or receipt of L/C

Radio Indirect Co2 Fire Detection Tube 5.7Mpa Working Pressure High Quality Cheap price

Radio Indirect Co2 Fire Detection Tube 5.7Mpa Working Pressure Parameter: No. Specification Technical parameter 1 Type Carbon dioxide indirect type 2 model WZ-Q/T-EZ6-XJ60 3 Working pressure 5.7Mpa 4 Max working pressure 12.1Mpa 5 Working temperature 0-49℃ 6 Density of unit volume 2.5kg/m3 7 Max length of detecting tube 25m 8 Quantity of agent 42kg Description: Indirect Co2 Fire Detection Tube is filled with 42kg Co2 . This type of extinguishing device can automatically put

Price: negotiation MOQ: 5 sets Delivery Time: 10-15 working days after payment or receipt of L/C

Xingjin Red High Quality Fm200 Fire Detection Tubing For Easy Installation And Maintenance

Professional Fm200 Fire Detection Tubing with 3kg Agent Single Zone Parameter: No. Specification Technical parameter 1 Type Fm200 direct type 2 model WZ-Q/T-QZ3-XJ60 3 Working pressure 2.5Mpa 4 Max working pressure 4.2Mpa 5 Working temperature 0-50℃ 6 Density of unit volume 0.7kg/m3 7 Max length of detecting tube 20m 8 Quantity of agent 3kg Applications: Fm200 fire detection tubing is commonly used in fire suppression systems to detect and suppress fires in various applicatio

Price: negotiation MOQ: 5 sets Delivery Time: 15-20 working days after payment or receipt of L/C

Fm200 Direct Type Fire Detection Tube Single Zone For Server Room / Data Center

Fm200 Direct Type Fire Detection Tube Single Zone For Server Room / Data Center Parameter: No. Specification Technical parameter 1 Type Fm200 direct type 2 model WZ-Q/T-QZ3-XJ60 3 Working pressure 2.5Mpa 4 Max working pressure 4.2Mpa 5 Working temperature 0-50℃ 6 Density of unit volume 0.7kg/m3 7 Max length of detecting tube 20m 8 Quantity of agent 3kg Description: Fm200 Direct Type Fire Detection Tube is filled with 3kg fm200 . It is a kind of colorless and tasteless and non

Price: negotiation MOQ: 5 sets Delivery Time: 10-15 working days after payment or receipt of L/C

Direct Carbon Dioxide Fire Detection Tube With CAL / CMA Certification

Direct Carbon Dioxide Fire Detection Tube With CAL / CMA Certification Parameter: No. Specification Technical parameter 1 Type Carbon dioxide direct type 2 model WZ-Q/T-EZ6-XJ60 3 Working pressure 5.7Mpa 4 Max working pressure 12.1Mpa 5 Working temperature 0-49℃ 6 Density of unit volume 2.5kg/m3 7 Max length of detecting tube 25m 8 Quantity of agent 6kg Description: Direct carbon dioxide fire detecting system is a kind of fire suppression system that has both warning and fire

Price: negotiation MOQ: 5 sets Delivery Time: 10-15 working days after payment or receipt of L/C

Hot Sale red Automatic Hfc 227ea Fire Detection Tube For Communications Lightweight Design With Low Maintenance

Hfc 227ea Fire Detection Tube For Communications , Broadcasting Parameter: No. Specification Technical parameter 1 Type Carbon dioxide direct type 2 model WZ-Q/T-EZ6-XJ60 3 Working pressure 5.7Mpa 4 Max working pressure 12.1Mpa 5 Working temperature 0-49℃ 6 Density of unit volume 2.5kg/m3 7 Max length of detecting tube 25m 8 Quantity of agent 42kg Description: The fm200 fire trace extinguisher is a kind of clean, colorless and odorless fire suppression system. Because of its

Price: negotiation MOQ: 5 sets Delivery Time: 10-15 working days after payment or receipt of L/C

42kg Co2 Fire Extinguishing Devices Fire Detection Tube Of Indirect Type: 0-49℃, 5.7-12.1Mpa

5.7Mpa - 12.1Mpa 42kg Co2 Fire Detection Tube of Indirect Type Parameter: No. Specification Technical parameter 1 Type Carbon dioxide direct type 2 model WZ-Q/T-EZ6-XJ60 3 Working pressure 5.7Mpa 4 Max working pressure 12.1Mpa 5 Working temperature 0-49℃ 6 Density of unit volume 2.5kg/m3 7 Max length of detecting tube 25m 8 Quantity of agent 42kg Description: 42kg Co2 Fire Detection Tube Of Indirect Type is one of our three types fire detection tube extinguishing system . It

Price: negotiation MOQ: 5 sets Delivery Time: 10-15 working days after payment or receipt of L/C

Novec1230 Hfc227ea White Fire Suppression Tube Automatic Cover 0.5 Cubic Meter

Novec1230 Hfc227ea White Fire Suppression Tube Automatic Cover 0.5 Cubic Meter Automatic fire suppression tube for car engine Description: Designed to automatically suppress fires in small enclosed areas. During a fire, the heat degrades will continue to rise and it will melt the storage tube which contains the extinguishing agent under pressure. The sensitive tube is made of special plastic with stainless fittings on either end. When meet the fire, the tube will be melted,

Price: negotiation MOQ: 100 sets Delivery Time: 10-15 working days

CO2 Fire Suppression System with No External Power Required and Dual-Function Detection Tube for Point-to-Point Precision Discharge

Traditional fire suppression systems often cannot be installed in confined spaces where electrical cabinets, control panels, and cable enclosures need protection. The CO2 fire detection tube system solves this problem through four key innovations. The system complies with GA1167-2014 industry standard for fire detection tube devices, ensuring stricter and more reliable technical performance . Specification Technical parameter Type CO 2 direct type CO 2 in direct type Capacity

Price: Pricing based on quantity MOQ: 100 set system Delivery Time: 15-20days

Non-Electric CO2 Fire Suppression System with Heat Sensing Tube for Server Room Protection

Fire risks in telecommunication base stations, data centers, power plants, and broadcasting facilities are significant – dense electrical equipment, complex cable trays, and confined spaces often make traditional fire suppression systems impractical. The CO2 fire detection tube system offers a proven solution for these challenging environments . The flexible detection tube can be routed directly inside equipment enclosures, over cable trays, and around electrical panels, with

Price: Pricing based on quantity MOQ: 100 set system Delivery Time: 15-20days

High Pressure Indirect CO2 Gas Fire Suppression System with Release Nozzle for Industrial Use

The CO2 fire detection tube system is an innovative fixed non-electric self-actuating fire suppression device that combines fire detection and extinguishing functions into a single flexible tube. Unlike traditional gas systems, it requires no power supply, no complex detectors, no control panels, and no intricate piping networks – making it ideal for protecting enclosed electrical cabinets, control panels, and compact equipment spaces where conventional systems cannot be

Price: Pricing based on quantity MOQ: 100 set system Delivery Time: 15-20days
1 2 3 4 5