NOUL 5C 0.75mm2 Industrial Spring Cable Tinned Copper Stranded PP Insulation TPU Jacket 300V
NOUL 5C×0.75mm2 Industrial Spring Cable Tinned Copper Stranded with PP Insulation and TPU Jacket 300V 80℃ ITEM 5C×0.75mm2(95/0.10T) CONDUCTOR Material Tinned copper stranded Size 95/0.10±0.008mm O.D.(Ref) 1.15mm INSULATION Material PP Min.average thickness 0.38mm Min.thickness at any point 0.33mm O.D. 2.00±0.10mm CABLING Filler cotton Material Paper Assembly 5C×0.75mm2(95/0.10T) JACKET Material TPU Min.average thickness 0.80mm Min.thickness at any point 0.64mm O.D. 7.90±0
Industrial Energy Storage Cable NOUL 14AWG 22AWG Tinned Copper Stranded FEP Insulation FEP Jacket 300V
NOUL 14AWG~22AWG Energy Storage Cable Tinned Copper Stranded with FEP Insulation 300V 200℃ Conductor Material Tinned copper Size 22AWG 20AWG 18AWG 16AWG 14AWG Construction 19/0.15mm 19/0.19mm 19/0.24mm 19/0.30mm 19/0.37mm Nominal Diameter 0.75mm 0.95mm 1.20mm 1.50mm 1.85mm Insulation Material FEP Nominal average thickness 0.30mm 0.30mm 0.30mm 0.30mm 0.30mm Diameter 1.45±0.10mm 1.65±0.10mm 1.90±0.10mm 2.20±0.10mm 2.60±0.15mm Color Per request Marking None Test Voltage(KV,AC) 2
UL20276 3C 26AWG Industrial Cable Tinned Copper Stranded PVC Insulation PVC Jacket 30V
UL20276 3C×26AWG Industrial Cable Tinned Copper Stranded with PVC Insulation and PVC Jacket 30V 80℃ Construction Conductor Tinned copper stranded Cross section 26AWG Construction 26/0.08mm Strand Dia.(Ref.) 0.47mm Insulation PVC Nom.Thickness 0.23mm Min.Thickness 0.18mm Insulation Dia. 1.00±0.10mm Insulation colour white,brown,green Filler Optional Material Non-woven Assembly 3C×26AWG+W Jacket PVC Nom.Thickness 0.51mm Min.Thickness 0.43mm Outer Dia. 3.80±0.20mm Colour Per
UL2854 3C 28AWG Industrial Wire Cable Bare Copper Stranded PVC Insulation PVC Jacket 30V
UL2854 3C×28AWG Industrial Cable Tinned Copper Stranded with PVC Insulation and PVC Jacket 30V 80℃ Construction Conductor Tinned copper stranded Cross section 28AWG Construction 7/0.127mm Strand Dia. 0.38mm Insulation PVC Nom.Thickness 0.23mm Min.Thickness 0.18mm Insulation Dia. 0.90±0.05mm Insulation colour 1.black 2.white 3.red Filler Optional Material Al-mylar(foil face out) ≥25% Drain Tinned copper stranded,7/0.127mm Assembly 3C×28AWG+AE Braid Tinned copper,0.10mm Min. 80
UL20549 8C 26AWG Tinned Copper Stranded Industrial Cable SR-PVC Insulation PU Jacket 300V
UL20549 8C×26AWG Industrial Cable Tinned Copper Stranded with SR-PVC Insulation and PU Jacket 300V 80℃ ITEM 8C×26AWG(7/0.16T)+W CONDUCTOR Material Tinned copper stranded Size 7/0.16±0.008mm O.D.(Ref) 0.48mm INSULATION Material SR-PVC Min.average thickness 0.23mm Min.thickness at any point 0.18mm O.D. 1.00±0.05mm CABLING Filler PP rope Material Non-woven Assembly 8C×26AWG(7/0.16T)+W JACKET Material PU Min.average thickness 0.76mm Min.thickness at any point 0.61mm O.D. 5.20±0
UL20327 7C 28AWG Copper Wire Tinned Copper Stranded Industrial Cable TPE Insulation TPE Jacket 300V 105C
UL20327 7Cx28AWG Industrial Cable Tinned Copper Stranded with TPE Insulation and TPE Jacket 300V 105℃ Construction Conductor Tinned copper stranded Cross section 28AWG Construction 7/0.127±0.008mm Strand Dia. 0.38mm Insulation TPE Nom.Thickness 0.20mm Min.Thickness 0.18mm Insulation Dia. 0.80±0.05mm Insulation colour 1.black 2.brown 3.red 4.orange 5.yellow 6.green 7.blue Filler None Material Al-mylar(foil face out),≥25% Drain wire Tinned copper stranded ,7/0.127±0.008mm
10C 24AWG Industrial Cable Tinned Copper Stranded SR-PVC Insulation PVC Jacket 300V
UL2517 10C×24AWG Industrial Cable Tinned Copper Stranded with SR-PVC Insulation and PVC Jacket 300V 105℃ ITEM 10C×24AWG(7/0.20T) CONDUCTOR Material Tinned copper stranded Size 7/0.20±0.008mm O.D.(Ref) 0.60mm INSULATION Material SR-PVC Min.average thickness 0.30mm Min.thickness at any point 0.25mm O.D. 1.25±0.03mm CABLING Filler PP rope Material Nonwoven tape JACKET Material PVC (UV and moisture resistance) Min.average thickness 0.76mm Min.thickness at any point 0.61mm O.D. 7
UL20327 4C 26AWG Industrial Cable Tinned Copper Stranded TPE Insulation TPE Jacket 300V 105C
UL20327 4C×26AWG Industrial Cable Tinned Copper Stranded with TPE Insulation and TPE Jacket 300V 105℃ ITEM 4C×26AWG(7/0.16T) CONDUCTOR Material Tinned copper stranded Size 7/0.16±0.008mm O.D.(Ref) 0.48mm INSULATION Material TPE(Halogen free) Min.average thickness 0.23mm Min.thickness at any point 0.18mm O.D. 1.00±0.05mm CABLING Material Non-woven Assembly 4C×26AWG(7/0.16T) JACKET Material TPE(Halogen free) Min.average thickness 0.76mm Min.thickness at any point 0.61mm O.D. 4
4C 0.50mm2 UL2464 Flexible Industrial Cable Bare Copper Stranded SR-PVC Insulation PVC Jacket 300V
UL2464 4C×0.50mm2 Flexible Industrial Cable Bare Copper Stranded with SR-PVC Insulation and PVC Jacket 300V 80℃ ITEM 4C×0.50mm2(100/0.08B)+W CONDUCTOR Material Bare copper stranded Size 100/0.08±0.008mm O.D.(Ref) 0.92mm INSULATION Material SR-PVC Min.average thickness 0.23mm Min.thickness at any point 0.18mm O.D. 1.50±0.10mm CABLING Filler Cotton Material Non-woven JACKET Material PVC Min.average thickness 0.76mm Min.thickness at any point 0.61mm O.D. 5.60±0.30mm Application:
UL10296 6AWG Industrial Energy Storage Cable Tinned Copper Stranded PVC Insulation 1000V
UL10296 6AWG Energy Storage Cable Tinned Copper Stranded with PVC Insulation 1000V 105℃ Construction Conductor Tinned copper stranded Cross section 6AWG Construction 1050/0.127mm Strand Dia.(Ref.) 5.10mm Insulation PVC Nom.Thickness 1.52mm Min.Thickness 1.37mm Insulation Dia. 8.60±0.30mm Insulation colour Per request Application: This product is applicable for connecttion between batteries, or batteries and inverters for mobile energy storage power station, energy storage
6C 20AWG UL2464 Tinned Copper Stranded Industrial Flexible Cable PVC Insulation PVC Jacket 300V
6C 20AWG UL2464 Tinned Copper Stranded Industrial Flexible Cable PVC Insulation PVC Jacket 300V Construction Conductor Tinned copper stranded Cross section 20AWG Construction 26/0.16mm Strand Dia. 0.94mm Insulation PVC Nom.Thickness 0.23mm Min.Thickness 0.18mm Insulation Dia. 1.50±0.10mm Insulation colour 1.white 2.brown 3.green 4.yellow 5.grey 6.pink Filler Optional Assembly 6C×20AWG Jacket PVC Nom.Thickness 0.76mm Min.Thickness 0.61mm O.D. 6.20±0.30mm Application: I nternal
5C 26AWG UL2464 Tinned Copper Stranded Industrial Flexible Cable SR-PVC Insulation PVC Jacket 300V
UL2464 5C×26AWG Tinned Copper Stranded Industrial Electric Cable with SR-PVC Insulation PVC Jacket 300V 80℃ ITEM 5C×26AWG(7/0.16T) CONDUCTOR Material Tinned copper stranded Size 7/0.16±0.008mm O.D. ( Ref ) 0.48mm INSULATION Material SR-PVC Min.average thickness 0.23mm Min.thickness at any point 0.18mm O.D. 1.00±0.05mm CABLING Filler PP rope Material Nonwoven tape JACKET Material PVC (UV resistance ) Min.average thickness 0.76mm Min.thickness at any point 0.61mm O.D. 4.50±0
UL3132 14AWG Industrial Energy Storage Cable Bare Copper Stranded SR Insulation 300V
UL3132 14AWG Energy Storage Silicone Cable Bare Copper Stranded with SR Insulation 300V 150℃ Construction Conductor Bare Copper Stranded Cross section 14AWG Construction 41/0.254mm Strand Dia. 1.88mm(Ref) Insulation SR(halogen free) Nom.Thickness 0.51mm Min.Thickness 0.46mm Insulation Dia. 3.60±0.20mm Insulation colour Per request Application: This product applies to automotive power lines and eneergy storage equipment. Electric Performance: Rated Temperature:-40~150℃ Voltage
Tinned Copper Stranded 3C 24AWG UL2586 Industrial Flexible Cable PVC Insulation PVC Jacket 600V FT-1
UL2586 3C×24AWG Tinned Copper Stranded Industrial Flexible Cable with PVC Insulation PVC Jacket 600V FT-1 ITEM 3C×24AWG(7/0.20T) CONDUCTOR Material Tinned copper stranded Size 7/0.20±0.008mm O.D.( Ref ) 0.60mm INSULATION Material PVC Min.average thickness 0.76mm Min.thickness at any point 0.69mm O.D. 2.20±0.10mm CABLING Assembly 3C×24AWG(7/0.20T) JACKET Material PVC Min.average thickness 0.90mm Min.thickness at any point 0.72mm O.D. 6.70±0.20mm Application: Internal wring or
UL2464 2C 20AWG Stranded Tinned Copper Wire PVC Insulation PVC Jacket Industrial Cable 300V
UL2464 2C×20AWG Tinned Copper Stranded Industrial Flexible Cable with PVC Insulation PVC Jacket Construction Conductor Tinned Copper Stranded Cross section 20AWG Construction 10/0.254mm Strand Dia. 1.02mm Insulation PVC Nom.Thickness 0.38mm Min.Thickness 0.33mm Insulation Dia. 1.90.±0.10mm Insulation colour 1.black 2.red Filler Optional Assembly 2C×20AWG Jacket PVC Nom.Thickness 0.76mm Min.Thickness 0.61mm O.D. 5.20±0.30mm Colour Per request Application: Internal wring or
3C 20AWG UL20233 Tinned Copper Stranded Industrial Flexible Cable XLPE Insulation TPU Jacket 300V
UL20233 3C×20AWG+W Tinned Copper Stranded Industrial Flexible Cable with XLPE Insulation and TPU Jacket Construction Conductor Tinned Copper Stranded Cross section 20AWG Construction 26/0.16mm Strand Dia. ( Ref. ) 0.94mm Insulation XLPE Nom.Thickness 0.23mm Min.Thickness 0.18mm Insulation Dia. 1.50±0.10mm Insulation colour 1.black 2.brown 3.red Filler Optional Material Non-woven Assembly 3C×20AWG+W Jacket TPU Nom.Thickness 0.76mm Min.Thickness 0.61mm O.D. 5.20±0.20mm Colour
4C 2.5mm2 UL2587 Bare Copper Stranded Industrial Flexible Cable PVC Insulation PVC Jacket 600V
UL2587 4C×2.5mm2 Bare Copper Stranded Industrial Cable With PVC Insulation PVC Jacket 600V Construction Conductor Bare copper stranded Cross section 2.50mm2 Construction 140/0.15mm Strand Dia. 2.05mm Insulation PVC Nom.Thickness 0.76mm Min.Thickness 0.69mm Insulation Dia. 3.70±0.15mm Insulation colour 1-3.black print number 1-3 4.green/yellow Material Non-woven Filler Optional Assembly 4C×2.5mm2+W Inner Jacket PVC Nom.Thickness 0.76mm Min.Thickness 0.61mm O.D. 11.00±0.30mm
4C 20AWG UL2464 Tinned Copper Stranded Industrial Flexible Cable PVC Insulation PVC Jacket 300V
4C 20AWG UL2464 Tinned Copper Stranded Industrial Flexible Cable PVC Insulation PVC Jacket 300V Construction Conductor Tinned copper stranded Cross section 20AWG Construction 26/0.16mm Strand Dia. 0.94mm Insulation PVC Nom.Thickness 0.23mm Min.Thickness 0.18mm Insulation Dia. 1.50±0.10mm Insulation colour 1.white 2.brown 3.green 4.yellow Filler Optional Material Al-mylar Foil face out ≥25% Assembly 4C×20AWG+A Braid Tinned copper , 0.10mm ,≥ 80% Jacket PVC Nom.Thickness 0.76mm
5C 8AWG UL2587 Industrial Copper Stranded Cable PVC Insulation PVC Jacket 600V
UL2587 5C×8AWG Industrial Cable Bare Copper Stranded with PVC Insulation and PVC Jacket 600V 90℃ ITEM 5C×8AWG(133/0.287B) CONDUCTOR Material Bare copper stranded Size 133/0.287mm O.D.(Ref) 4.30mm INSULATION Material PVC Min.average thickness 0.76mm Min.thickness at any point 0.69mm O.D. 5.80±0.20mm CABLING Filler PP rope Material Mylar Assembly 5C×8AWG(133/0.287B) JACKET Material PVC Min.average thickness 1.14mm Min.thickness at any point 0.92mm O.D. 18.80±0.40m Application:
3P 24AWG UL2464 Flexible Industrial Cable Bare Copper Stranded SR-PVC Insulation PVC Jacket 300V
UL2464 3P×24AWG Flexible Industrial Cable Bare Copper Stranded with SR-PVC Insulation and PVC Jacket 300V 80℃ ITEM 3P×24AWG(44/0.08B)+AB CONDUCTOR Material Bared copper stranded Size 44/0.08±0.008mm O.D.( Ref ) 0.61mm INSULATION Material SR-PVC Min.average thickness 0.23mm Min.thickness at any point 0.18mm O.D. 1.15±0.05mm TWISTED OD .(Ref) 2.30mm CABLING Filler Cotton+Nylon Material Al-mylar(foil face out) BRAID Material Tinned copper Size 0.10±0.008mm(80% min.) JACKET