CPT-III Large Screen Automatic CT PT Analysis Instrument CT PT Analyzer
CPT-III Large Screen Automatic CT PT Analysis Instrument CT PT Analyzer Introduction: CPT-III CT Analyzer is used to measure all kinds of current transformer and voltage transformer. It can calculate the ratio errors and phase angle errors of current transformer and voltage transformer at rated burden and working burden in one test. CPT-III ct pt tester can automatically evaluate the test results according to the selected standard to determine whether the transformer is
Current Output
0.001~5A RMS
Description
CT PT Volt-Ampere Characteristic Analyzer
Size
485mm * 356mm * 183mm
Packaging Details
CT PT Analyzer is packed in plywood case.
Delivery Lead Time
7 Days
Operation
Touch Screen
Product Description
CPT-III Large Screen Automatic CT PT Analysis Instrument CT PT Analyzer
Introduction:
- CPT-III CT Analyzer is used to measure all kinds of current transformer and voltage transformer.
- It can calculate the ratio errors and phase angle errors of current transformer and voltage transformer at rated burden and working burden in one test.
- CPT-III ct pt tester can automatically evaluate the test results according to the selected standard to determine whether the transformer is qualified.
Parameters:
- Test standards: IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
- Power supply: AC220V±10%, 50/60Hz±10%
- Voltage output: 0.1~180V (AC)
- Current output: 0.001~5A(RMS)
- Power output: 500VA
- Maximum knee voltage measurement: 45KV
- PT ratio error measurement: typical error <0.05%, maximum error<0.1%
- PT phase angle measurement: maximum error < 3min
- Memory capacity: >1000 groups test results
- Working condition: temperature: -10ºC~50ºC, humidty: ≤90%
- Size: 485mm * 356mm * 183mm, weight: <15kg
| Test Parameters | Range | Error | Resolution |
| Current | 0~10A (automatically change range in 0.1/0.4/2/10A) | <±0.1%+0.01%FS | / |
| Voltage | 0~200V (automatically change range in 1V/10V/70V/200V) |
<±0.1%+0.01%FS | / |
| Turns Ratio | 1~5000 | <0.05% | / |
| 5000~35000 | <0.1% | / | |
| Phase | / | ±2min | Resolution: 0.01min |
| Winding Resistance | 0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm) | <0.2%RDG+0.02%FS | Max. resolution: 0.1mΩ |
| Temperature | -50~100 Celsius degree | <3 Celsius degree | / |
| CT Secondary Burden | 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm) |
<0.2%RDG+0.02%FS | Max. resolution: 0.001ohm |
| PT Secondary Burden | 0~80kohm (automatically change range in 800ohm/8kohm/80kohm) |
<0.2%RDG+0.02%FS | Max. resolution: 0.1ohm |
| PT Ratio | 1~10000 | <0.1% | / |
| 10000~35000 | <0.2% | / |
Functions of test software:
- Make evaluation for test results according to selected standards.
- Make word report for test result.
- Make word reports one time for multi-group test records on the PC.
- Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test.
- Compare excitation curves with saved excitation curves in the same window.
Recommended Products
Price: USD1.0 Cable Withstand Voltage Tester / set
Price: USD1.0 / set AC DC Dry Type Hipot Tester
Price: Negotiable
Price: USD1.0 / set
Price: USD1.0 / set Transformer Power Factor Tester
Interested in this product?