Closed Loop Hall Effect Current Sensor TBC-ES565 Series 10A to 100A Rated Input
TBC-ES565 series closed loop Hall effect current sensor offers high precision 1000:1 resolution for DC, AC and pulse current measurement. Features galvanic isolation, ±0.1% linearity, 200kHz bandwidth, and <0.5µs response time. Supports custom rated input and output voltage. Compliant with UL94-V0, EN60947-1, and IEC60950-1.
DC AC Closed Loop Hall Effect Current Sensor TBC-ES565 Series
TBC-ES565 Series current sensor is a closed loop device based on the measuring principle of the hall effect and null balance method ,with a galvanic isolation between primary and secondary circuit, the size of primary not affect test precision, no matter the location of primary in the hole of current sensor, It really measuring resolution 1000:1 and it uses for precision measurement of DC, AC and pulse current.
| Electrical data(Ta=25℃±5℃) |
| Type Parameter |
TBC10ES565 | TBC25ES565 | TBC50ES565 | TBC75ES565 | TBC100ES565 | Unit |
Rated input (Ipn) |
10 | 25 | 50 | 75 | 100 | A |
Measure range(Ip) |
32 | 80 | 150 | 225 | 300 | A |
| Turns ratio(Np/Ns) | 1:960 | 1:1200 | 1:1200 | 1:1200 | 1:1200 | |
|
Internal measuring resistance |
15±0.1% | 7.5±0.1% | 3.75±0.1% | 2.5±0.1% | 1.875±0.1% | Ω |
| Rated output | @Ip=±Ipn ±0.625±0.3% | V | ||||
| Supply voltage | +5±2% | V | ||||
| Power consumption | ≤20+IpX(Np/Ns) | mA | ||||
| Reference voltage | +2.5±0.4% | V | ||||
Zero voltage |
@Ip=0 +2.5±0.4%FS | V | ||||
| Offset drift | @ -40℃~105℃ ≤±0.05 | mV/℃ | ||||
output drift |
@ -40℃~105℃ ≤±0.05 | mV/℃ | ||||
| Linearity | @Ip=0-±Ipn ≤0.1 | %FS | ||||
| Bandwidth | @ -3db 0~200 | KHz | ||||
Response time |
@100A/μS,10%-90% <0.5 | µs | ||||
Galvanic isolation |
@ 50HZ,AC,1min 3 | KV | ||||
| Applications |
Variable speed drives
Welding machine
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Electrochemical
| Mechanical dimension(for reference only) |
Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm
| Directions for use |
Is will be in a forward direction when the Ip flows according to the direction of the arrowhead.
The primary conductor should be≤120℃.
The dynamic performance (di/dt and the response time) is the best when the primary hole is fully filled with the bus bar.
The primary turns should be at the top of the sensor for the best magnetic coupling.
When the current will be measured goes through a sensor, the voltage will be measured at the output end.
(Note: The false wiring may result in the damage of the sensor)
Custom design in the different rated input current and the output voltage are available.
|
Standards |
- UL94-V0.
- EN60947-1:2004
- IEC60950-1:2001
- EN50178:1998
- SJ 20790-2000
| General date |
| Value | Unit | Symbol | |
| Operating temperature | -40 to +105 | ºC | TA |
| Storage temperature | -40 to +125 | ºC | TS |
| Mass(approx) | 15 | g | M |
| Characteristics chart |
Pulse current signal response characteristic Effects of impulse noise