100-2000A Open Loop Hall Effect Current Sensor ±1% Accuracy DC AC Pulse

TKC-BHS5 series open loop Hall effect sensor offers ±1% accuracy for DC, AC, and pulse current measurement from 100 to 2000A. Features galvanic isolation, low offset drift, and fast response. Ideal for UPS, SMPS, and variable speed drives. Custom options available.

principle Open Loop Hall Effect Current Sensor
Usage Instrument
Place of Origin Nanjing,China
Theory Hall Sensor,Current Sensor
Packaging Details Little carton:34*23*21CM 36pcs/carton;Large carton size 48*37*26CM 72pcs/carton
Input current 100-2000A
Product Description

100-2000A Open Loop Hall Effect Current Sensor with ±1% Accuracy

 

TKC-BHS5 Series high precision current sensor is a open loop device based on the measuring principle of the hall effect ,with a galvanic isolation between primary and secondary circuit, the size of primary not affect test precision, no matter the location of primary in the hole of current sensor, It uses for precision measurement of DC, AC and pulse current.

 

Electrical data(Ta=25℃±5℃,RL=2KΩ,CL=10000PF)

 

Type

Parameter

TKC20

BHS5

TKC50

BHS5

TKC100

BHS5

TKC200

BHS5

TKC300

BHS5

TKC450

BHS5

TKC500

BHS5

 

Unit


Rated input (Ipn)
±20 ±50 ±100 ±200 ±300 ±450 ±500 A

Measure range(Ip)
±40 ±100 ±200 ±400 ±600 ±900 ±1000 A

Rated output
@Ip=0-±Ipn ±1.0±0.5% V

 

Zero voltage

@Ip=0 2.5±0.4% V

 

Reference voltage

2.5±0.4% V

Supply voltage
+5±5% V

 

Power Consumption

≤20 mA

Offset voltage
≤±5.0 mV

Magnetic offset
±5.0 ±3.0 mV

Offset drift
≤±0.2 ≤±0.1 mV/℃

output drift
≤±0.5 ≤±0.3 mV/℃

Linearity
@Ip=0-±Ipn ≤0.5 %FS

Response time
@100A/μS, 10%-90% ≤5 μS

Bandwidth
@ -3dB DC~30 KHZ

Galvanic isolation
@ 50HZ,AC,1min 2.5 KV

 

 

Applications

AC variable speed drives

Static converters for DC motor drives

Variable speed drives

Power supplies for welding applications

Battery supplied applications

Uninterruptible Power Supplies (UPS)

Switched Mode Power Supplies(SMPS)

 

Mechanical dimension(for reference only)

Remarks:

1. All dimensions are in mm.

2. General tolerance ±1mm.

 

Directions for use

When the current will be measured goes through a sensor, the voltage will be measured at the output end.

(Note: The false wiring may result in the damage of the sensor)

Customs can adjust Output amplitude of the sensor by needs.

Custom design in the different rated input current and the output voltage are available.

 

Standards

 

  • UL94-V0.
  • EN60947-1:2004
  • IEC60950-1:2001
  • EN50178:1998
  • SJ 20790-2000

General date

  Value Unit Symbol
Operating temperature -40 to +105 ºC TA
Storage temperature -40 to +125 ºC TS
Mass(approx) 65 g M

 

Characteristics chart

 

Pulse current signal response characteristic       Effects of impulse noise