UL94-V0 Open Loop Hall Effect Current Sensor 100-2000A Input Current ±15V Supply

Accurate open loop Hall effect sensor for DC, AC or pulsed currents from 100 to 2000A. Features galvanic isolation, fast response ≤5μs, and UL94-V0 certification. Custom input/output options available for industrial applications.

principle hall effect
Place of Origin Nanjing,China
Packaging Details Little carton:34*23*21CM 36pcs/carton;Large carton size 48*37*26CM 72pcs/carton
Input current 100-2000A
Model Number TKC-N/NR
Supply Ability 10K pcs per month
Product Description

 

UL94-V0 Open Loop Hall Effect Current Sensor 100-2000A Input Current

 

 

 

The TKC-N/NR series current sensor is a open loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents.

 

Electrical data (Ta=25℃±5℃,RL=2KΩ,CL=10000PF)

 

Type

Parameter

TKC100N/NR TKC200N/NR TKC300N/NR TKC400N/NR TKC500N/NR TKC600N/NR

 

Unit


Rated input (Ipn)
±100 ±200 ±300 ±400 ±500 ±600 A

Measure range(Ip)
±300 ±600 ±900 ±1000 ±1000 ±1000 A

Rated output
@Ip=±Ipn ±4±1% V

Supply voltage
±15 ±5% V

 

Power Consumption

+18,-10 mA

Offset voltage
@Ip=0 ≤25 mV

Magnetic offset
@Ip=±Ipn ≤±30 mV

Offset drift
@ -40℃~+85℃ ≤±0.5 mV/℃

output drift
@ -40℃~+85℃ ≤±0.5 mV/℃

Linearity
@Ip=0-±Ipn ≤1 %FS

Response time
@50A/μS, 10%-90% ≤5 μS

Galvanic isolation
@ 50HZ,AC,1min 3.0 KV

 

 

Applications

 

Variable speed drives

Welding machine

Battery supplied applications

Uninterruptible Power Supplies (UPS)

Electrochemical

Switched Mode Power Supplies (SMPS)

 

 

Mechanical dimension(for reference only)

 


Remarks:

1. All dimensions are in mm.

2. General tolerance ±1mm.

 

 

Directions for use

 

When the current will be measured goes through a sensor, the voltage will be measured at the output end.

(Note: The false wiring may result in the damage of the sensor).

Customs can adjust Output amplitude of the sensor by needs.

Custom design in the different rated input current and the output voltage are available.

 

 

Standards

 

  • UL94-V0.
  • EN60947-1:2004
  • IEC60950-1:2001
  • EN50178:1998
  • SJ 20790-2000

 

General date

 

  Value  Unit  Symbol
Operating temperature -40 to +85 ºC TA
Storage temperature -40 to +125 ºC TS
Mass(approx) 79 g M

 

 

Characteristics chart

 

 

Pulse current signal response characteristic       Effects of impulse noise

Recommended Products

Interested in this product?
Contact us now for more details and a custom quote.