China Open Loop Hall Effect Current Sensor TKC Series 50A to 600A High Sensitivity for sale
China Open Loop Hall Effect Current Sensor TKC Series 50A to 600A High Sensitivity for sale

Open Loop Hall Effect Current Sensor TKC Series 50A to 600A High Sensitivity

High sensitivity open loop Hall effect current sensor for DC, AC, and pulse signals. Rated input ±50 to ±600A with ±15V supply. Features galvanic isolation 2.5KV, fast response ≤3μS, and low offset drift. UL94-V0 certified. Custom output voltage available.

principle hall effect
Place of Origin Nanjing,China
Packaging Details Little carton:34*23*21CM 36pcs/carton;Large carton size 48*37*26CM 72pcs/carton
Model Number TKC-BR
Electrical data Ta=25℃±5℃
Supply Ability 10K pcs per month
Product Description

 

High Sensitivity Hall Effect Sensor Non Contact Current Sensor Ta=25℃±5℃

 

Introductions


These are newly developed open loop hall current sensor series which can be used for detecting of DC,AC, high frequency, pulse as well as various of irregular wave of current signals.
Primary and secondary isolation, pressure and safety.
Applied to a single power supply system,power supply and output voltage support customized.

 

Applications

 

AC variable speed drives

Static converters for DC motor drives

Variable speed drives

Power supplies for welding applications

Battery supplied applications

Uninterruptible Power Supplies (UPS)

Switched Mode Power Supplies(SMPS)

 

Electrical data(Ta=25℃±5℃,RL=2KΩ,CL=10000PF)

 

Type

Parameter
TKC50BR TKC75BR TKC100BR TKC200BR TKC300BR TKC400BR TKC500BR TKC600BR

 

Unit


Rated input
±50 ±75 ±100 ±200 ±300 ±400 ±500 ±600 A

Measure range
±150 ±225 ±300 ±600 ±900 ±900 ±900 ±900 A

Rated output
@Ip=±Ipn ±4±1% V

Supply voltage
±15 ±5% V

 

Consumption

+18,-10 mA

Offset voltage
±25 mV

Magnetic offset
±30 ±25 @Ip=±Ipn mV

Offset drift
≤±1.5 ≤±1.0 mV/℃

output drift
≤±1.5 ≤±1.0 mV/℃

Linearity
@Ip=0-±Ipn ≤1 %FS

Response time
@50A/μS, 10%-90% ≤3 μS

Galvanic isolation
@ 50HZ,AC,1min 2.5 KV

 

Wire length

650~750 mm

 

 

Mechanical dimension(for reference only)

 

Remarks:

1. All dimensions are in mm.

2. General tolerance ±1mm.

 

 

Directions for use

 

When the current will be measured goes through a sensor, the voltage will be measured at the output end.

(Note: The false wiring may result in the damage of the sensor)

Customs can adjust Output amplitude of the sensor by needs.

Custom design in the different rated input current and the output voltage are available.

 

 

Standards

 

  • UL94-V0.
  • EN60947-1:2004
  • IEC60950-1:2001
  • EN50178:1998
  • SJ 20790-2000

 

General date

 

  Value Unit Symbol
Operating temperature -40 to +85 ºC TA
Storage temperature -40to +125 ºC TS
Mass(approx) 80 g M

 

 

Characteristics chart

 

 

Pulse current signal response characteristic     Effects of impulse noise

 

 

Input current-Output Voltage characteristic

 

 

 

Interested in this product?
Contact us now for more details and a custom quote.