Clean Agent Fire Suppression Hfc-227ea Fire System

Clean agent fire suppression hfc-227ea fire system Description: • Cabinet automatic HFC-227ea/FM200(Heptafluoropropane) fire suppression system uses the solenoid valve as the starting mode with the elegant appearance design. The cylinder is placed in the cabinet. For different protection zone, according to the different volume zone to match different size cylinder, which can reduce the occupied area. • According to different volume size, different extinguishing agent,

Agent HFC-227ea (FM200)
Place of Origin China
Packaging Details Plywood outer box with bubble bag or paper
Actuation Automatic, Manual, Mechanical emergency manual
Model Number GQQ40/2.5, GQQ70/2.5, GQQ90/2.5, GQQ100/2.5, GQQ120/2.5, GQQ150/2.5, GQQ180/2.5
Supply Ability 30000 set system
Product Description

Clean agent fire suppression hfc-227ea fire system

 

 

Description:

 

• Cabinet automatic HFC-227ea/FM200(Heptafluoropropane) fire suppression system uses the solenoid valve as the starting mode with the elegant appearance design. The cylinder is placed in the cabinet. For different protection zone, according to the different volume zone to match different size cylinder, which can reduce the occupied area.

 

• According to different volume size, different extinguishing agent, different starting mode to assemble.

 

• Independent sets, flexible installation, good appearance.

 

• Without cylinder room, can install in the protection zone, handy and romovable.

 

• Automatic HFC-227ea/FM200(Heptafluoropropane) fire extinguishing system is a set of fire extinguishing, automatic control and fire detection in one system which is the modern intelligent automatic fire extinguishing device.

 

• HFC-227ea/FM200 (Heptafluoropropane) is a kind of colourless, tasteless, not conduct electricity and no secondary pollution gas. It belongs to a kind of clean extinguishing agent.

 

• The ozone-depleting potential value is zero.

 

• Cleanness, low toxicity, good electrical insulation, higher fire extinguishing efficiency.

 

• It is currently an ideal substitute for the halon extinguishing agent.

 

 

 

Parameter:

 

NO. Specifications Parameters
1 Cylinder capacity 40Ltr,70Ltr,90Ltr,100Ltr,
120Ltr,150Ltr,180Ltr
2 Device model GQQ40/2.5, GQQ70/2.5, GQQ90/2.5, GQQ100/2.5, GQQ120/2.5, GQQ150/2.5, GQQ180/2.5
3 Filling pressure 2.5Mpa
4 Max filling rate 0.95kg/L
5 Discharge time ≤10s
6 Working temperature 0℃~50℃
7 Max working pressure 4.2Mpa
8 Discharge pressure 5.6±0.28Mpa
9 Proportion of protected zone ≤500m²
10 Volume of protected zone ≤1600m³
11 Actuation Automatic or manual start

 

Cabinet Size

 

Specification Size(mm) Volume(cbm) Net weight (kg)
GQQ40/2.5 500×450×1450 0.326 33
GQQ70/2.5 500×450×1450 0.326 43-50
GQQ90/2.5 500×450×1650 0.371 43-50(46)
GQQ100/2.5 500×450×1650 0.371 55-64(54)
GQQ120/2.5 550×550×1900 0.575 60-73(60)
GQQ150/2.5 550×550×1900 0.575 80
GQQ180/2.5 600×550×2150 0.71 80

 

 

Applications:

 

    Electronic computer room, a data processing center, telecommunications facilities, process control, expensive medical equipment, industrial equipment, library, museum and art gallery, clean room, anechoic chamber, emergency power facilities, flammable liquid storage area, etc.

 

    The place where the fire is easy to happen, like paint-spraying production line, aging-electrical equipment, rolling machine, printing machine, oil switch, oil immersed transformer, melt impregnating tank, tank, large generators, drying equipment, cement pro duction process of pulverized coal, and the ship's engine room, cargo hold, etc.

 

 

Compositions:

 

   

Actually, a complete one set system contains two parts: the extinguishing device(the whole composition is like the photo beside) and electrical elements.

 

One set cabinet type fm200 fire suppression device is formed by the following components: fm200 agents, a fm200 cylinder, a hoop, a cabinet, a container valve, a solenoid actuator, a flexible hose(high pressure hose), nozzle(s) and pressure switch.

 

                

 

 

Attentions:

 

    There are some points users need to notice when they are using this system.

 

1/ The volume of the protected zone shouldn't be bigger than 1600 cubic metres; the proportion of the protected zone should be smaller than 500 square metres.

 

2/ If there some problems occur, users shouldn't fix or touch it themselves. The best solution is to call and tell us the problems, and wait for our professionals.

 

3/ Users better follow the routine check schedual that we provide.

 

4/ unless everthing is at its position, the cover of the small ball valve can be unclosed.

 

Recommended Products

China Data Center FM200 Fire Suppression System with 40 Hanging Tank for sale Video
Price: negotiation
China Enclosed Flooding FM200 Fire Suppression System Without Pollution For Library for sale Video
China 180L Low Toxicity FM-200 Fire Suppression System for Electrical Cabinets for sale Video
Price: negotiation
China HFC 227ea Fire Extinguishing System, Suspension, Manual/Electrical Start for sale Video
Price: negotiation
China 4.2Mpa Hfc-227Ea Fm200 Fire Extinguisher System Without Network for sale Video
Price: negotiation
China One Zone HFC 227ea Fire Extinguishing System Colorless And Tasteless for sale Video
Price: negotiation
China Hanging Hfc-227ea Extinguishing System with Electrical Actuator for sale Video
Price: negotiation
Interested in this product?
Contact us now for more details and a custom quote.