Home Products Temperature Transmitters

Temperature Transmitters

Showing 46 Products

HART 7 PR 3337 Temperature Converter Loop-Powered 0.05% Accuracy Pre-Calibrated Ranges

HART 7 temperature converter with 0.05% accuracy, loop-powered design, and global certifications (ATEX/IECEx/FM). Features stainless steel housing, programmable response times, and compatibility with gases/liquids. DIN rail mounting for industrial applications.

Price: 200-500usd MOQ: 1 Delivery Time: 5-7 work days

PR 3111 TC Converter Temperature Transmitter 0.05% Accuracy 6.1 mm Slimline Housing Selectable Response Time

TC converter with 0.05% accuracy, HART communication, and ATEX/IECEx certifications. Features slim 6.1mm housing, selectable response times, and robust industrial performance for temperature applications.

Price: 200-400usd MOQ: 1 Delivery Time: 5-7 work days

PR 3102 Pt100 converter 0.1% accuracy excellent EMC performance selectable response time

PR 3102 Pt100 converter offers excellent

Price: 200-400usd MOQ: 1 Delivery Time: 5-7 work days

High Accuracy TC Converter Temperature Transmitters PR 3101 Stainless Steel Housing IP65

TC Converter PR 3101 Excellent accuracy, better than 0.1% of span Excellent EMC performance and 50/60 Hz noise suppression Selectable < 30 ms / 300 ms response time Pre-calibrated temperature range Environmental Conditions Operating temperature-25°C to +70°C Storage temperature-40°C to +85°C Calibration temperature20...28°C Relative humidity< 95% RH (non-cond.) Protection degreeIP20 Installation inPollution degree 2 & meas. / overvoltage cat. II Mechanical Specifications

Price: 250-280usd MOQ: 1 Delivery Time: 5-7 work days

PROFIBUS PA Profile 4.0 Temperature Transmitters PR 5450D With RTD / TC / Potentiometer Inputs

PROFIBUS PA Temperature Transmitter PR 5450D Product Overview PROFIBUS PA Profile 4.0 compatible temperature transmitter supporting RTD, TC, potentiometer, linear resistance and bipolar mV inputs. Features single or true dual inputs with sensor redundancy and drift detection capabilities. Environmental Conditions Operating temperature -40°C to +80°C Storage temperature -50°C to +85°C Calibration temperature 23...25°C Relative humidity < 99% RH (non-condensing) Protection

Price: 435 MOQ: 1 Delivery Time: 5-7 work days

2 Wire Level Transmitter PR 5343B With Programmable Sensor Error Value Unique Process Calibration Function

2-Wire Level Transmitter PR 5343B Product Overview Potentiometer or Ohmic input Programmable sensor error value High measurement accuracy Unique process calibration function Programmable via standard PC Environmental Conditions Operating temperature-40°C to +85°C Calibration temperature20...28°C Relative humidity< 95% RH (non-cond.) Protection degree (encl./terminal)IP68 / IP00 Mechanical Specifications DimensionsØ 44 x 20.2 mm Weight approx.50 g Wire size1 x 1.5 mm² stranded

Price: 144usd MOQ: 1 Delivery Time: 5-7 work days

HART 7 Protocol Temperature Transmitters PR 5337D With 0.05% Accuracy IP68 Protection

2-Wire Transmitter with HART Protocol Model PR 5337D Key Features RTD, TC, Ohm, and bipolar mV input capability 2 analog inputs with 5 device variables and status monitoring Selectable HART protocol revision (HART 5 or HART 7) Environmental Conditions Operating temperature-40°C to +85°C Calibration temperature20...28°C Relative humidity< 95% RH (non-condensing) Protection degree (enclosure/terminal)IP68 / IP00 Mechanical Specifications DimensionsØ 44 x 20.2 mm Weight approx

Price: 84 MOQ: 1 Delivery Time: 5-7 work days

2 Wire HART Transmitter PR 5335D With 0.05% Accuracy HART 5 Protocol And Galvanic Isolation

2-Wire HART Transmitter PR 5335DRTD Product Overview 2-wire transmitter with HART 5 protocol TC, Ohm, or mV input compatibility Extremely high measurement accuracy Galvanic isolation Designed for DIN form B sensor head mounting Environmental Conditions Operating temperature-40°C to +85°C Calibration temperature20...28°C Relative humidity< 95% RH (non-condensing) Protection degree (enclosure/terminal)IP68 / IP00 Mechanical Specifications DimensionsØ 44 x 20.2 mm Weight approx

Price: 87 MOQ: 1 Delivery Time: 5-7 work days

2 Wire Programmable Transmitter PR 5334B High Accuracy With Galvanic Isolation Programmable Sensor Error Value

2-wire programmable transmitter PR 5334B Product Overview TC input with high measurement accuracy Galvanic isolation for enhanced safety Programmable sensor error value Designed for DIN form B sensor head mounting Environmental Conditions Operating temperature -40°C to +85°C Calibration temperature 20...28°C Relative humidity < 95% RH (non-condensing) Protection degree (enclosure/terminal) IP68 / IP00 Mechanical Specifications Dimensions Ø 44 x 20.2 mm Weight approx. 50 g

Price: 80usd MOQ: 1 Delivery Time: 5-7 work days

High Measurement Accuracy Programmable Transmitter PR 5333D With 3 Wire Connection Programmable Sensor Error Value

2-Wire Programmable Transmitter PR 5333D RTD or Ohm input with high measurement accuracy 3-wire connection configuration Programmable sensor error value Designed for DIN form B sensor head mounting Environmental Conditions Operating temperature-40°C to +85°C Calibration temperature20...28°C Relative humidity< 95% RH (non-condensing) Protection degree (enclosure/terminal)IP68 / IP00 Mechanical Specifications DimensionsØ 44 x 20.2 mm Weight approx.50 g Wire size1 x 1.5 mm²

Price: 58 MOQ: 1 Delivery Time: 5-7 work days

2 Wire Programmable RTD Transmitter 4-20ma PR 5332D For Precise Temperature Measurement

2-Wire Programmable RTD Transmitter PR 5332D Input Type: RTD or Ohm Accuracy: Better than 0.05% of selected range Features: Programmable sensor error value Mounting: For DIN form B sensor head Environmental Conditions Operating temperature -40°C to +85°C Calibration temperature 20...28°C Relative humidity < 95% RH (non-condensing) Protection degree (enclosure/terminal) IP68 / IP00 Mechanical Specifications Dimensions Ø 44 x 20.2 mm Weight approx. 50 g Wire size 1 x 1.5 mm²

Price: 116usd MOQ: 1 Delivery Time: 5-7 work days

PR 9113A Din Rail Temperature Transmitters With 4-20 MA Output

Temperature / mA Converter PR 9113A Product Overview Input for RTD, TC and mA signals Active/passive mA output via the same two terminals Available in 1 or 2 channel configurations Can be supplied separately or installed on power rail, PR type 94 Environmental Conditions Operating temperature-20°C to +60°C Storage temperature-20°C to +85°C Calibration temperature20...28°C Relative humidity< 95% RH (non-condensing) Protection degreeIP20 Installation inPollution degree 2 &

Price: 58usd MOQ: 1 Delivery Time: 5-7 work days

2-wire HART 7 Temperature Transmitters PR 6437A With RTD TC MV Inputs

PR 6437A 2-Wire HART 7 Temperature Transmitter Product Overview Advanced 2-wire HART 7 temperature transmitter supporting RTD, TC, potentiometer, linear resistance and bipolar mV inputs. Features single or true dual inputs with sensor redundancy and drift detection capabilities. Environmental Conditions Operating temperature -50°C to +85°C (standard) -40°C to +80°C (SIL) Storage temperature -50°C to +85°C Calibration temperature 23...25°C Relative humidity < 99% RH (non-cond.

Price: 170usd MOQ: 1 Delivery Time: 5-7 work days

PR 6337A Temperature Transmitters HART 7 Protocol For RTD TC Signals In DIN Rail Mounting

2-Wire HART Transmitter PR 6337A 1- or 2-channel converter for RTD, TC, Ohm, and bipolar mV signals with 2 analogue inputs and 5 device variables with status available. HART protocol revision selectable. Environmental Conditions Operating temperature -40°C to +85°C Storage temperature -40°C to +85°C Calibration temperature 20...28°C Relative humidity < 95% RH (non-condensing) Protection degree IP20 Mechanical Specifications Dimensions (HxWxD) 109 x 23.5 x 104 mm Weight (1 / 2

Price: 150 MOQ: 1 Delivery Time: 5-7 work days

HART 5 Protocol Temperature Transmitter PR 6335A 2 Wire With Galvanic Isolation

PR 6335A 2-wire HART Transmitter RTD, TC, Ohm, or mV input capability Extremely high measurement accuracy HART 5 protocol compatibility Galvanic isolation Available in 1- or 2-channel versions Environmental Conditions Operating temperature -40°C to +85°C Storage temperature -40°C to +85°C Calibration temperature 20...28°C Relative humidity < 95% RH (non-condensing) Protection degree IP20 Mechanical Specifications Dimensions (HxWxD) 109 x 23.5 x 104 mm Weight (1 / 2 channels)

Price: 150usd MOQ: 1 Delivery Time: 5-7 work days

High Accuracy Programmable Measurement Transmitter PR 6334A With Galvanic Isolation

PR 6334A 2-Wire Programmable Transmitter Product Overview TC input capability High measurement accuracy Galvanic isolation Programmable sensor error value Available in 1- or 2-channel versions Environmental Conditions Operating temperature-40°C to +85°C Storage temperature-40°C to +85°C Calibration temperature20...28°C Relative humidity< 95% RH (non-condensing) Protection degreeIP20 Mechanical Specifications Dimensions (HxWxD)109 x 23.5 x 104 mm Weight (1 / 2 channels)145 /

Price: 160usd MOQ: 1 Delivery Time: 5-7 work days

High Measurement Accuracy Programmable Transmitter PR 6333A With 3 Wire Connection

2-Wire Programmable Transmitter PR 6333A Product Overview RTD or Ohm input capability High measurement accuracy 3-wire connection system Programmable sensor error value Available in 1- or 2-channel versions Environmental Conditions Operating temperature-40°C to +85°C Storage temperature-40°C to +85°C Calibration temperature20...28°C Relative humidity< 95% RH (non-condensing) Protection degreeIP20 Mechanical Specifications Dimensions (HxWxD)109 x 23.5 x 104 mm Weight (1 / 2

Price: 280usd MOQ: 1 Delivery Time: 5-7 work days

Precise 2 Wire Programmable Transmitter PR 6331A Temperature Monitoring High Accuracy

PR 6331A 2-Wire Programmable Transmitter Key Features RTD, TC, Ohm, or mV input capability Extremely high measurement accuracy Galvanic isolation for enhanced safety Programmable sensor error value Available in 1- or 2-channel versions Environmental Conditions Operating temperature-40°C to +85°C Storage temperature-40°C to +85°C Calibration temperature20...28°C Relative humidity< 95% RH (non-condensing) Protection degreeIP20 Mechanical Specifications Dimensions (HxWxD)109 x

Price: 320USD MOQ: 1 Delivery Time: 5-7 work days

PROFIBUS PA Temperature Transmitters PR 5450A With PROFIBUS PA Profile 4.0 Multiple Input Options

PROFIBUS PA Temperature Transmitter Model PR 5450A Key Features PROFIBUS PA profile 4.0 compatibility Multiple input types: RTD, TC, potentiometer, linear resistance and bipolar mV Single or true dual inputs with sensor redundancy Drift detection capability Environmental Conditions Operating temperature -40°C to +80°C Storage temperature -50°C to +85°C Calibration temperature 23...25°C Relative humidity < 99% RH (non-condensing) Protection degree (enclosure/terminal) IP68 /

Price: 362usd MOQ: 1 Delivery Time: 5-7 work days

2 Wire HART 7 Temperature Transmitter PR 5437A With RTD TC Potentiometer Input IP65 / IP67

PR 5437A 2-Wire HART 7 Temperature Transmitter Key Features RTD, TC, potentiometer, linear resistance and bipolar mV input capability Single or true dual inputs with sensor redundancy and drift detection Wide ambient operating temperature range HART 7 protocol compatibility Environmental Conditions Operating temperature -50°C to +85°C (standard) -40°C to +80°C (SIL) Storage temperature -50°C to +85°C Calibration temperature 23...25°C Relative humidity < 99% RH (non-condensing

Price: 100usd MOQ: 1 Delivery Time: 5-7 work days