Fire Testing Equipment
UL1581 Wire Heating Deformation Testing Machine For Test The Degree Of Thermal Deformation
UL1581 Wire Heating Deformation Testing Machine Uses Used to test the degree of thermal deformation of materials such as plastic and wire skin Technical Parameters Test device: 3 groups Temperature: normal temperature ~300 °C Weight: 50, 100, 200, 500, 1000g each three Scale: Japan MITOTOYO 0.01/10mm Volume: inner box size: length 600mm * depth 400mm * height 360mm Outer box size: length 1100mm* width 620mm* height 1730mm Inner box material: SUS#304 stainless steel. Outer box
Cable Installed Vertically In Shafts Fire Testing Machine
UL 1666 Cable Installed Vertically in Shafts Fire Testing Machine Testing Standards UL1666, ANSI/ASTM D 5207 & UL 1581, ANSI/ASTM D 5025 UL1666 Parameters 1. U-type pressure gauge: measuring chamber pressure maintained at 0-12PA; 2. Hygrometer: measuring chamber temperature and humidity; 3. The structure of the chamber: the overall structure of the concrete wall by the brick, the first layer is 1.22M, the second layer is 3.66M, the top is 2.24M. External dimensions: 7.12M
IEC 60331-21 Fire Testing Equipment Wire Flame Small Lab Oven Without Combustion Chamber
IEC60331-21 Wire Flame Test Chamber Standards IEC 60331-21 Tests for electric cables under fire conditions - Circuit integrity - Part 21: Procedures and requirements - Cables of rated voltage up to and including 0,6/1,0 kV Specification 2. Cable and cable line integrity combustion test machine design principle: The cable and cable integrity fire tester is divided into three parts: the combustion box, the combustion frame, and the control box, all of which are individually
IEC61034 Wires & Cables Smoke Density Tester with Steel Structure Combustion Chamber
IEC61034 Wires & Cables Smoke Density Tester with Steel Structure Combustion Chamber Description According to IEC61034-1~2,the first parts of "test device" and second part of "test steps and requirements" for the determination of smoke density of cables or optical cables under specific conditions. The determination of smoke density is an important aspect of assessing the combustion characteristics of cable or cable, which is related to the evacuation of the personnel and
Smoke Density Test Machine For Wire And Cable
Smoke Density Test Machine For Wire And Cable IEC61034-1~2 Product information According to GB/T17651.1~2 and IEC61034-1~2,the first parts of "test device" and second part of "test steps and requirements" for the determination of smoke density of cables or optical cables under specific conditions. The determination of smoke density is an important aspect of assessing the combustion characteristics of cable or cable, which is related to the evacuation of the personnel and the
1000V Fire Testing Equipment Wire & Cable Resistance To Fire With Water IEC60331-11
1000V Flammability Testing Equipment Wire & Cable Resistance to Fire with Water IEC60331-11 Standards According to IEC60331-11, IEC60331-21, IEC 60331-1, IEC 60331-2, EN50200, EN50362, BS6387: 1994, BS7846, BS8431-1, BS8434-2, BS8491 etc. Use Used for testing wires & cables with the rated voltage through the different refractory level,detect the fire resistance of the insulation, check insulation whether breakdown and circuit’s integrality. Main parameters Testing power AC0
IEC60695-2-10~13 Glow-Wire Fire Testing Equipment
Glow-wire Flammability Testing Equipment IEC60695-2-10~13 GB/T5169 Standards According to IEC60695-2-10~13,UL746A, IEC829, DIN695, VDE0471etc. Features 1.The flaming chamber and control part of the integrated design, convenient installation and operation. 2.The shell of chamber and main parts made of stainless steel, which resistant smoke and withstand the rust of gas 3.SCR automatic control system to automatically adjust the current to achieve the purpose of control the
Fire Testing Equipment 95% Gas Purity Mining Cable Burning Tester
95% Gas Purity Mining Cable Burning Tester MT386-1995 / MT818.1~3-2009 Application Apples to check the coal mine cable for flaming resistance test and cable connector head flaming test. Standard According to MT386-1995 and MT818.1~3-2009 Technology parameters Load current AC10.0~3000A adjustable, Adopt the touch button for setting Burner Inner diameter is 9.5mm, burner tube made by H62 brass Flame height inner flame is 75±5mm and outside flame is 125±10mm Gas Methane which
IEC60331-11 Wire & Cable Resistance To Fire Mechanical Shock Tester / Flammability Test Chamber
Wire & Cable Resistance To Fire Mechanical Shock Tester / Flammability Test Chamber Application Used for testing wires & cables with the rated voltage through the different refractory level, detect the fire resistance of the insulation, check insulation whether breakdown and circuit’s integrality. Standards According to IEC60331-11, IEC60331-21, IEC 60331-1, IEC 60331-2, EN50200, EN50362, BS6387: 1994, BS7846, BS8431-1, BS8434-2, BS8491 etc. Main parameters Shock testing wall
IEC60331-11:19999 Over Current Fire Testing Equipment For Wires And Cables Resistance To Fire
Over-current Flammability Testing Equipment For Wires and Cables Resistance to Fire Application Applies to check the test integrity of the circuit for wires or cables, use to check the flame retardant properties of insulating refractory characteristics of cable and wires and cables with fireproof layer under overheating, over-current, etc abnormal condition. Standards According to IEC60331-11:19999, IEC60331-21:1999, IEC60331-23:1999, IEC60331-25:1999, and BS6387 Technical
IEC60695-11-03 Fire Testing Equipment Single Cable Vertical Flammability Tester
IEC60695-11-03 Single Cable Vertical Flammability Tester Product introduction Single Cable Combustion Tester is the most widely used and lower cost of cable fire performance test equipment, which can meet the standards IEC 60332-1-1:2004 in the provisions of technical indicators and requirements. Single cable combustion Tester is used to test the flame retardant property of the cable's insulating layer under abnormal conditions such as overheat and overcurrent. It can be used
Single Insulated Wire and Cable Vertical Flame Test
Single Insulated Wire and Cable Vertical Flame Test Equipment Application Applies to check thesingle insulation wire and cable vertical spreading test which total section area less than 0.5mm2. Standards According to IEC60332-1-1:2004, IEC60332-1-2:2004, IEC60332-1-3:2004, EN50265-1, EN50265-2-1. Techncial parameters Vertical burning chamber W300xH1200xD450mm Gas Use high purity propane gas or liquefied petroleum gas (provide by user-self) Specimen length 600±25mm Area of
Fire Testing Equipment / Vertical Flame Test Chamber
Gas Flow Range 0.1-1L/min Vertical Flame Test Chamber Application Applies to check the section area more than 0.5mm2 of single insulation wire and cable vertical flame propagation testing. Standards According to IEC60332-1-1:2004, IEC60332-1-2:2004, IEC60332-1-3:2004, EN50265-1, EN50265-2-1 Functional characteristics The vertical burning test on single wire and cable is the provisions of the size of the lamp (Bunsen burner and specific gas source (propane), according to the
SL-FL51 Wires & Cables Smoke Density Test Room
IEC61034-1997 Photocell Sensor Wires & Cables Smoke Density Test Room Application Applies to check the size quantity of producing smoke of cables or optical fiber under prescriptive fire source. Standards According to IEC61034-1997, GA306.1-2007, GA306.2-2007. Technical parameters Burning room size W3000*D3000*H3000mm (27m3), made of stainless steel Standard fire source 1.00L±0.01L alcohol Illuminant nominal power 100w, nominal voltage:DC12v±0.01V Sensor photocell, load
SL-FL38 UL1581 Cable H / V Stainless Steel Fire Testing Equipment
Cable H / V Stainless Steel Flammability Testing Equipment Standards According to the clause 1060 (vertical burning and FT1 test), 1061(cables burning test), 1080(VW-1 burning test), 1090(electric cable specimen horizontal burning test, optional item), 1100 (horizontal specimen/ FT2 burning test)of UL1581-2008, 6.8 (standard arcing test), clause 9.1~9.5 of UL2556-2007, clause 4.26 of JIS C3005-2000 Application Apply to check the single cable flaming test for FT1, FT2/FH
UL Cable Vertical Tray Fire Testing Equipment
UL Cable Vertical-Tray Flammability Testing Equipment With 5.7inch Color Touch Screen Application Apply to check the vertical-tray fire test for determining values of cable flame propagation and smoke release when the cables are subjected to a flaming ignition source. (It is nothing to the purpose of cables, such as the electric power, telecommunications etc.) Main components Main consist of Ignition source & supply fire control system, collection hood & exhaust duct flux
11mm Nozzle SL-FL76 Vertical Combustion Tester (16CFR1615/1616) for testing CHILDREN'S SLEEPWEAR
SL-FL76 Vertical combustion tester (16CFR1615/1616) Application: The Vertical Combustion Tester is suitable for measuring the flame retardant properties of various flame retardant textiles (such as woven fabrics, knitted fabrics, coated products, laminated products, etc.). Determining the tendency of textiles to burn, smolder and char. Standards: 16CFR 1615(Size 0-6), 16CFR1616 (Size 7-14) STANDARD FOR THE FLAMMABILITY OF CHILDREN'S SLEEPWEAR Principle: Install the sample in
ISO 1182 Non Combustibility Test Apparatus 900 ℃ Max Temperature
ISO 1182 Non Combustibility Test Apparatus Non-Combustibility Tester Performance Characteristics Measures incombustibility of uniform and non-uniform building materials Evaluates rising furnace temperature, mass loss, and specimen ignition Single Zone Furnace operates up to 900℃ with Kanthal Ribbon Heater Precise 750±5℃ temperature control via PID and Power controller Stabilized voltage supply for rapid temperature stabilization Three thermocouples monitor furnace, specimen
ISO 9150/BS EN 348 Protective Clothing Molten Metal Splashes Impact Resistance Tester
EN 384/ISO 9150 Molten Metal Splashes Impact Test Apparatus Product Introduction Projections of molten metal drops at a point on a vertical oriented test specimen and measurement of the number of the drops required to cause a 40 K temperature rise in a sensor behind the specimen. Features Drop guide to collect the drops and to guide them towards the vertically oriented test specimen. Senor for measuring the temperature linked to a recording device. Holding frame and
ISO 9185 Tests Protective Clothing For Molten Metal Splash Tester Fabric Test Machine
ISO 9185 Molten Metal Splash Test Device Product Profile The thermal penetration resistance of protective clothing materials used to prevent a large number of molten metal splashes was evaluated by the anti-liquid molten metal splashing test device developed according to ISO9185 standard. Medium such as molten aluminium, molten cryolite, molten copper, molten iron and spatter of molten low carbon steel directly acted on the surface of the material. The penetration resistance