JY-PLP-70+ Precision Low Pass Filter DC-60 MHz 50 Ohm Hermetically Sealed Case

Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Pass Band DC-60 - - - MHz Cutoff Frequency (fco, 3 dB) - - 67 - MHz Insertion Loss DC-60 - - 1.0 dB VSWR DC-60 - 1.7 - :1 Stop Band, Rejection (Loss > 20 dB) 90-117 20 - - dB Stop Band, Rejection (Loss > 40 dB) 117-300 40 - - dB Features rugged welded case, hermetic other standard and custom PLP models available with wide selection of fco Applications test equipment lab use transmitters/receivers military

Price: Negotiable MOQ: Negotiable Delivery Time: Negotiable

JY-PLP-50+ Precision Low Pass Filter DC-48 MHz 50 Ohm Hermetically Sealed Case

Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Pass Band DC-48 - - - MHz Cutoff Frequency (fco, 3 dB) - - 55 - MHz Insertion Loss DC-48 - - 1.0 dB VSWR DC-48 - 1.7 - :1 Stop Band, Rejection (Loss > 20 dB) 70-90 20 - - dB Stop Band, Rejection (Loss > 40 dB) 90-200 40 - - dB Features rugged welded case, hermetic other standard and custom PLP models available with wide selection of fco Applications test equipment lab use transmitters/receivers military

Price: Negotiable MOQ: Negotiable Delivery Time: Negotiable

JY-PLP-30+ Precision Low Pass Filter DC-32 MHz 50 Ohm Hermetically Sealed Case

Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Pass Band DC-32 - - - MHz Cutoff Frequency (fco, 3 dB) - - 35 - MHz Insertion Loss DC-32 - - 1.0 dB VSWR DC-32 - 1.7 - :1 Stop Band, Rejection (Loss > 20 dB) 47-61 20 - - dB Stop Band, Rejection (Loss > 40 dB) 61-200 40 - - dB Features rugged welded case, hermetic other standard and custom PLP models available with wide selection of fco Applications test equipment lab use transmitters/receivers military

Price: Negotiable MOQ: Negotiable Delivery Time: Negotiable

JY-PLP-21.4+ Precision Low Pass Filter DC-22 MHz 50 Ohm Hermetically Sealed Case

Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Pass Band DC-22 - - - MHz Cutoff Frequency (fco, 3 dB) - - 24.5 - MHz Insertion Loss DC-22 - - 1.0 dB VSWR DC-22 - 1.7 - :1 Stop Band, Rejection (Loss > 20 dB) 32-41 20 - - dB Stop Band, Rejection (Loss > 40 dB) 41-200 40 - - dB Features rugged welded case, hermetic other standard and custom PLP models available with wide selection of fco Applications test equipment lab use transmitters/receivers military

Price: Negotiable MOQ: Negotiable Delivery Time: Negotiable

JY-PLP-15-75+ Precision Low Pass Filter DC-15 MHz 75 Ohm Hermetically Sealed Case

Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Pass Band DC-15 - - - MHz Cutoff Frequency (fco, 3 dB) - - 17 - MHz Insertion Loss DC-15 - - 1.0 dB VSWR DC-15 - 1.7 - :1 Stop Band, Rejection (Loss > 20 dB) 23-32 20 - - dB Stop Band, Rejection (Loss > 40 dB) 32-200 40 - - dB Features rugged welded case, hermetic other standard and custom PLP models available with wide selection of fco Applications test equipment lab use transmitters/receivers military

Price: Negotiable MOQ: Negotiable Delivery Time: Negotiable

JY-PLP-15+ Precision Low Pass Filter DC-15 MHz 50 Ohm Hermetically Sealed Case

Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Pass Band DC-15 - - - MHz Cutoff Frequency (fco, 3 dB) - - 17 - MHz Insertion Loss DC-15 - - 1.0 dB VSWR DC-15 - 1.7 - :1 Stop Band, Rejection (Loss > 20 dB) 23-32 20 - - dB Stop Band, Rejection (Loss > 40 dB) 32-200 40 - - dB Features rugged welded case, hermetic other standard and custom PLP models available with wide selection of fco Applications test equipment lab use transmitters/receivers military

Price: Negotiable MOQ: Negotiable Delivery Time: Negotiable

JY-PLP-10.7+ Precision Low Pass Filter DC-11 MHz 50 Ohm Hermetically Sealed Case

Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Pass Band DC-11 - - - MHz Cutoff Frequency (fco, 3 dB) - - 14 - MHz Insertion Loss DC-11 - - 1.0 dB VSWR DC-11 - 1.7 - :1 Stop Band, Rejection (Loss > 20 dB) 19-24 20 - - dB Stop Band, Rejection (Loss > 40 dB) 24-200 40 - - dB Features rugged welded case, hermetic other standard and custom PLP models available with wide selection of fco Applications test equipment lab use transmitters/receivers military

Price: Negotiable MOQ: Negotiable Delivery Time: Negotiable

JY-PLP-7-75+ Precision Low Pass Filter DC-7 MHz 75 Ohm Hermetically Sealed Case

Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Pass Band DC-7 - - - MHz Cutoff Frequency (fco, 3 dB) - - 8 - MHz Insertion Loss DC-7 - - 1.0 dB VSWR DC-7 - 1.7 - :1 Stop Band, Rejection (Loss > 20 dB) 11-15 20 - - dB Stop Band, Rejection (Loss > 40 dB) 15-200 40 - - dB Features rugged welded case, hermetic other standard and custom PLP models available with wide selection of fco Applications test equipment lab use transmitters/receivers military/hi

Price: Negotiable MOQ: Negotiable Delivery Time: Negotiable

JY-PLP-5+ Precision Low Pass Filter DC-5 MHz 50 Ohm Hermetically Sealed Case

Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Pass Band DC-5 - - - MHz Cutoff Frequency (fco, 3 dB) - - 6 - MHz Insertion Loss DC-5 - - 1.0 dB VSWR DC-5 - 1.7 - :1 Stop Band, Rejection (Loss > 20 dB) 8-10 20 - - dB Stop Band, Rejection (Loss > 40 dB) 10-200 40 - - dB Features rugged welded case, hermetic other standard and custom PLP models available with wide selection of fco Applications test equipment lab use transmitters/receivers military/hi-rel

Price: Negotiable MOQ: Negotiable Delivery Time: Negotiable

JY-PLP-2.5+ Precision Low Pass Filter DC-2.5 MHz 50 Ohm Hermetically Sealed Case

Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Pass Band DC-2.5 - - - MHz Cutoff Frequency (fco, 3 dB) - - 2.75 - MHz Insertion Loss DC-2.5 - - 1.0 dB VSWR DC-2.5 - 1.7 - :1 Stop Band, Rejection (Loss > 20 dB) 3.8-5.0 20 - - dB Stop Band, Rejection (Loss > 40 dB) 5.0-200 40 - - dB Features rugged welded case, hermetic other standard and custom PLP models available with wide selection of fco Applications test equipment lab use transmitters/receivers

Price: Negotiable MOQ: Negotiable Delivery Time: Negotiable

JY-PLP-1.9+ Precision Low Pass Filter DC-1.9 MHz 50 Ohm Hermetically Sealed Case

Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Pass Band DC-1.9 - - - MHz Cutoff Frequency (fco, 3 dB) - - 2.5 - MHz Insertion Loss DC-1.9 - - 1.0 dB VSWR DC-1.9 - 1.7 - :1 Stop Band, Rejection (Loss > 20 dB) 3.4-4.7 20 - - dB Stop Band, Rejection (Loss > 40 dB) 4.7-200 40 - - dB Features rugged welded case, hermetic other standard and custom PLP models available with wide selection of fco Applications test equipment lab use transmitters/receivers

Price: Negotiable MOQ: Negotiable Delivery Time: Negotiable

JY-PHP-250+ High Pass Filter 225-1200 MHz 50 Ohm Shielded Case Surface Mount

Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Pass Band 225-1200 - - - MHz Cutoff Frequency (fco, 3 dB) - - 205 - MHz Insertion Loss 225-1200 - - 1.0 dB VSWR 225-1200 - 1.3 - :1 Stop Band, Rejection (Loss > 40 dB) DC-100 40 - - dB Stop Band, Rejection (Loss > 20 dB) 100-150 20 - - dB Stop Band, VSWR DC-150 - 17 - :1 Features rugged welded case, hermetic other standard and custom PLP models available with wide selection of fco Applications lab use

Price: Negotiable MOQ: Negotiable Delivery Time: Negotiable

JY-PBP-60+ Bandpass Filter 55-67 MHz 50 Ohm Shielded Case Surface Mount

Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Pass Band 55-67 MHz - - - MHz Center Frequency - - 60 - MHz Insertion Loss 55-67 MHz - - 1.5 dB 3 dB Bandwidth 49.8-70.5 MHz - - - MHz VSWR 55-67 MHz - - 1.7 :1 Stop Band, Lower (Loss > 20 dB) DC-44 20 - - dB Stop Band, Upper (Loss > 20 dB) 79-1000 20 - - dB Stop Band, Lower (Loss > 35 dB) DC-4.6 35 - - dB Stop Band, Upper (Loss > 35 dB) 190-1000 35 - - dB Features low insertion loss, 1.5 dB max good

Price: Negotiable MOQ: Negotiable Delivery Time: Negotiable

JY-PBP-10.7+ Bandpass Filter 9.5-11.5 MHz 50 Ohm Shielded Case Surface Mount

Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Pass Band 9.5-11.5 MHz - - - MHz Center Frequency - - 10.7 - MHz Insertion Loss 9.5-11.5 MHz - - 1.5 dB 3 dB Bandwidth 8.9-12.7 MHz - - - MHz VSWR 9.5-11.5 MHz - - 1.7 :1 Stop Band, Lower (Loss > 20 dB) DC-7.5 20 - - dB Stop Band, Upper (Loss > 20 dB) 15-1000 20 - - dB Stop Band, Lower (Loss > 35 dB) DC-0.6 35 - - dB Stop Band, Upper (Loss > 35 dB) 50-1000 35 - - dB Features low insertion loss, 1.5 dB max

Price: Negotiable MOQ: Negotiable Delivery Time: Negotiable

JY-LPF-B500+ Low Pass Filter DC-500 MHz 50 Ohm Shielded Case Surface Mount

Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Pass Band DC-500 - - - MHz Cutoff Frequency (fco, 3 dB) - - 515 - MHz Insertion Loss DC-500 - 1.2 2.0 dB VSWR DC-500 - 1.3 1.7 :1 Stop Band, Rejection 585-4500 20 31 - dB Stop Band, VSWR 585-4500 - 24 - :1 Features High rejection, 31 dB typical Sharp insertion loss roll-off Miniature shielded case Aqueous washable Applications Defence communications Transmitters / receivers Harmonic rejection Maximum

Price: Negotiable MOQ: Negotiable Delivery Time: Negotiable

JY-LPF-B375+ Low Pass Filter DC-375 MHz 50 Ohm Shielded Case Surface Mount

Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Pass Band DC-375 - - - MHz Cutoff Frequency (fco, 3 dB) - - 395 - MHz Insertion Loss DC-375 - 1.0 2.0 dB VSWR DC-375 - 1.3 1.6 :1 Stop Band, Rejection 440-4500 20 34 - dB Stop Band, VSWR 440-4500 - 23 - :1 Features High rejection, 36 dB typical Sharp insertion loss roll-off Miniature shielded case Aqueous washable Applications Defence communications Transmitters / receivers Harmonic rejection Maximum

Price: Negotiable MOQ: Negotiable Delivery Time: Negotiable

JY-LPF-B50+ Low Pass Filter DC-50 MHz 50 Ohm Shielded Case Surface Mount

Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Pass Band DC-50 - - - MHz Cutoff Frequency (fco, 3 dB) - - 55 - MHz Insertion Loss DC-50 - 0.8 2.0 dB VSWR DC-50 - 1.2 1.5 :1 Stop Band, Rejection 65-3300 20 36 - dB Stop Band, VSWR 65-3300 - 18 - :1 Features High rejection, 36 dB typical Sharp insertion loss roll-off Shielded case Aqueous washable Applications Defence communications Transmitters / receivers Harmonic rejection Maximum Ratings Operating

Price: Negotiable MOQ: Negotiable Delivery Time: Negotiable

JY-LPF-B35+ Low Pass Filter DC-35 MHz 50 Ohm Shielded Case Surface Mount

Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Pass Band DC-35 - - - MHz Cutoff Frequency (fco, 3 dB) - - 40 - MHz Insertion Loss DC-35 - 0.85 2.0 dB VSWR DC-35 - 1.5 2.0 :1 Stop Band, Rejection 45-2500 20 30 - dB Stop Band, VSWR 45-2500 - 15 - :1 Features High rejection, 30 dB typical Sharp insertion loss roll-off Shielded case Aqueous washable Applications Defence communications Transmitters / receivers Harmonic rejection Maximum Ratings Operating

Price: Negotiable MOQ: Negotiable Delivery Time: Negotiable

JY-LPF-B0R8+ Low Pass Filter DC-0.8 MHz 50 Ohm Shielded Case Surface Mount

Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Pass Band DC-0.8 - - - MHz Cutoff Frequency (fco, 3 dB) - - 1.25 - MHz Insertion Loss DC-0.8 - - 1.5 dB VSWR DC-0.8 - 1.1 - :1 Stop Band, Rejection (Loss > 20 dB) 1.55-1.75 20 - - dB Stop Band, Rejection (Loss > 40 dB) 1.75-1000 40 - - dB Features high rejection good VSWR, 1.1:1 typ. @ passband shielded case aqueous washable Applications CDMA cellular infrastructure wireless communications receivers /

Price: Negotiable MOQ: Negotiable Delivery Time: Negotiable

JY-LPF-B0R7+ Low Pass Filter DC-0.7 MHz 50 Ohm Shielded Case Surface Mount

Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Pass Band DC-0.7 - - - MHz Cutoff Frequency (fco, 3 dB) - - 1.08 - MHz Insertion Loss DC-0.7 - - 1.5 dB VSWR DC-0.7 - 1.2 - :1 Stop Band, Rejection (Loss > 20 dB) 1.30-1.46 20 - - dB Stop Band, Rejection (Loss > 40 dB) 1.46-1000 40 - - dB Features high rejection good VSWR, 1.2:1 typ. @ passband shielded case aqueous washable Applications CDMA cellular infrastructure wireless communications receivers /

Price: Negotiable MOQ: Negotiable Delivery Time: Negotiable
27 28 29 30 31