25kV Composite Station Post Insulator for HIgh Voltage Transmission Line

25kV Composite Station Post Insulator for HIgh Voltage Transmission Line TECHNICAL DATA: Rated Voltage (kV) Height (mm) Creepage Distance (mm) Specified Cantilever Load (SCL) End Fittings Power Frequency Withstand Voltage (Wet/Dry) (kV) Lightning Impulse Withstand Voltage (kV) 25 500±10 1215 10 kN Stud hole ≥130 ≥230 FEATURES: Secure and reliable product with the capability of high cantilever strength. Compact design and light weight which gives great convenience to

Price: Negotiable MOQ: 10 pcs Delivery Time: 45~50 days EXW Wuhan

362kV Composite Line Post Insulator 4kN With Two Hole Blade And Flange

362kV Composite Line Post Insulator 4kN With Two Hole Blade And Flange If client has request, Wuhan Line Power can provide CO(Certificate of Origin) according to relevent Government Policy. REASONABLE DESIGN DRAWING RAW MATERIALS The insulator is made of composite materials of high resistance to moisture, ultraviolet radiation, high temperatures and tropical sunshine conditions. The core is made of resin-impregnated glass fibres free from defects. The housing of the insulator

Price: Negotiable MOQ: 10 pcs Delivery Time: 45~50 days EXW Wuhan

5KN 12KV Composite Post Insulator , Low Voltage Insulators With Two Holes Flange

12kV Composite Post Insulator 5kN with Two Holes Flange For Low Voltages Design Drawing TECHNICAL DATE Rated Voltage (kV) Height (mm) Dry Arcing Distance (mm) Leakage Distance (mm) SCL (kN) No. of Sheds Diameter of Rod (mm) Wet Power Frequency Withstand Voltage (kV) Lightning Impulse Withstand Voltage (kV) 12 102±5 60 127 5 2 20 15 30 CHARACTERISTICS We can design, manufacturer, test and supply the insulators according to IEC 61952, other applicable or latest IEC standards

Price: Negotiable MOQ: 10 pcs Delivery Time: 35~ 40days EXW Wuhan

Composite Post Type Insulator , 115kV Suspension Type Insulators Overhead Lines

115kV Composite Horizontal Line Post Insulator 10kN With Clamptop Clamp And Flange Products Standard: IEC 61952. Package: Paper Tube on Pallet. Raw Material for FZSW-115/10 End Fittings Core Sheds and Housing Materials: Hot dip galvanized cast iron or cast steel Epoxy & Glass fiber HTV Silicone Rubber Min. thickness of the galvanization: 86μm Rod Diameter: Φ70mm Color: Grey Designed Drawing For FZSW-115/10 TECHNICAL DATE Maximum System Voltage (kV) Height (mm) Dry Arcing

Price: Negotiable MOQ: 10 pcs Delivery Time: 45~50 days EXW Wuhan

Composite Polymer Line Post Insulators Grey Electric Insulation Fittings 252kV 12.5kN

Composite Polymer Line Post Insulators Grey Electric Insulation Fittings 252kV 12.5kN TECHANICAL DATA Rated Voltage(kV)SCL(kN)Height(mm)Min. Creepage Distance(mm)Lightning Impulse Withstand Voltage(kV)Min. Power Frequency Withstand Voltage(kV)25212.52300±3.86804≥950≥395 Welcome to provide technical parameters for customization! RAW MATERIALS End-fittingEnd-fitting TypeCoreDiameter of the CoreWeather ShedsColor Cast Iron or Cast Steel, Hot Dip Galvanized(thickness of the

Price: Negotiable MOQ: 10 pcs Delivery Time: 40~50 days

252kV 20kN Composite Post Insulator / Substation Post Insulator ISO9001 ISO14001

252kV 20kN Composite Post Insulator / Substation Post Insulator ISO9001 ISO14001 TECHANICAL DATA Rated Voltage(kV)SCL(kN)Height(mm)Min. Creepage Distance(mm)Lightning Impulse Withstand Voltage(kV)Min. Power Frequency Withstand Voltage(kV)252202300±3.86300≥950≥395 Welcome to provide technical parameters for customization! RAW MATERIALS End-fittingEnd-fitting TypeCoreDiameter of the CoreWeather ShedsColor Cast Iron or Cast Steel, Hot Dip Galvanized(thickness of the galvanizatio

Price: Negotiable MOQ: 10 pcs Delivery Time: 40~50 days

52kV Composite Line Post Insulator , Silicone Rubber with Top and Bottom Flange

52kV Composite Line Post Insulator , Silicone Rubber with Top and Bottom Flange TECHNICAL DATA: Rated Voltage (kV) Height (mm) Creepage Distance (mm) Specified Cantilever Load (SCL) End Fittings Power Frequency Withstand Voltage (Wet/Dry) (kV) Lightning Impulse Withstand Voltage (kV) 52 500±10 1215 15 kN Flange and Flange ≥130 ≥230 RAW MATERIALS: 1. End-fitting: 1.1 Material: Cast Steel, Hot Dip Galvanized. 1.2 Minimum thickness of the galvanization: 86μm. 2. Core: 2.1

Price: Negotiable MOQ: 10 pcs Delivery Time: 40~50 days EXW Wuhan

Station Composite Post Insulator 126KV Flange Composite Polymer Insulator

126KV Flange Composite Polymer Insulator, Station Post Inslators Materials: 1) HTV Silicon Rubber for Sheds and Housing 2) Glass-fiber Reinforced Epoxy Resin Rod (ECR type) for Core. 3) Hot Dip Galvanized Cast Iron/Steel for Flanges. Electromechanical specifications: 1) Rated voltage:126kV 2)Power Frequency Withstand Voltage(Wet1 min):230KV Mechanical Specifications: Specified Cantilever Strength:10kN Inspection before installation: Type Test-Sampling Test -Routine Test

Price: Negotiable MOQ: 10PCS Delivery Time: Negotiable According to the Qty.

69KV 32.9kN Composite Post Insulator With Clamp Flange High Temperature Resistance

Composite Line Post Insulator Features: 1. The silicone rubber housing of Composite Line Post Insulator was taken shape by whole injection. It has good hydrophobicity, hydrophobicity migration and soil resistance, as well as excellent electrical insulation properties and aging resistance, which could prevent effectively those accidents of pollution flashover so as to ensure the safe running of high voltage transmission lines. 2. The modified ECR fiberglass reinforced epoxy

Price: Negotiable MOQ: 10 pcs Delivery Time: 40-60 Working Days

138kV Horizontal Composite Insulator 13kN Line Post Insulators With Clamptop Clamp And Flat Base

138kV Horizontal Composite Insulator 13kN Line Post Insulators With Clamptop Clamp And Flat Base TECHNICAL DATE Maximum System Voltage (kV) Height (mm) Min. Dry Arcing Distance (mm) Min. Creepage Distance (mm) Specified Cantilever Load (SCL) Max. Design Cantilever Load (MDCL) Specified Tension Load Lower Frequency Flashover Voltage (Dry/Wet) (kV) Positive Critical Impulse Flashover Voltage (kV) 138 1615±40 1380 4200 13kN 6.4kN 30kN 520/405 805 Features: 1. Composite

Price: Negotiable MOQ: 10PCS Delivery Time: 40-60 days from order confirmed

33kV 10kN Composite Post Insulator for Overhead Power Lines , IEC 61952

33kV 10kN Composite Post Insulator for Overhead Power Lines CHARACTERISTICS We can design, manufacturer, test and supply the insulators according to IEC 61952, other applicable or latest IEC standards and the requirements of Clients. The insulator is made of composite materials of high resistance to moisture, ultraviolet radiation, high temperatures and tropical sunshine conditions. The core is made of resin-impregnated glass fibres free from defects. The housing of the

Price: Negotiable MOQ: 10PCS Delivery Time: 40-60 days after order confirmed

170KV,12.5kN Polymers Composite Post Insulator , Flange Post Insulators for Transmission Line

170KV,12.5kN Polymers Insulator, Flange Post Insulators for Transmission Line Electromechanical specifications: 1) Rated voltage:170kV 2) Power Frequency Withstand Voltage(Wet1 min):275KV 3) Lighting Impulse Withstand Voltage:675kV 4) Specified Cantilever Load:12.5kN Materials: 1) Gray Silicon Rubber for sheds/ housing 2) Glass-fiber reinforced epoxy resin rod (ECR type) for core. 3) Hot Dip Galvanized Cast Iron/Steel for Flanges.