China Particulate Matter Online CEMS Continuous Emission Monitoring System Gas Analyzer 0-50 mg/m3 24V DC for sale
China Particulate Matter Online CEMS Continuous Emission Monitoring System Gas Analyzer 0-50 mg/m3 24V DC for sale

Particulate Matter Online CEMS Continuous Emission Monitoring System Gas Analyzer 0-50 mg/m3 24V DC

Extractive laser forward scattering CEMS for continuous particulate monitoring. Features ±2% FS accuracy, 2 mg/m³ sensitivity, and dual-range measurement (0-50 mg/m³ low, 0-10 g/m³ high). Supports RS485/4-20 mA output, LCD display, and customizable high-temperature options up to 300°C. Ideal for stack sizes 1-15 m.

Applicable Stack Size 1-15m
Sample Condition Temperature Max 300 Celsius
Place of Origin Nanjing, China
Packaging Details Neutral carton
Display Mode 128*64 LCD
Error ≤±2%F.S
Product Description
Online Gas Analyzer Ultra Low Range Dust CEMS Continuous Particulate Matter Emission Monitoring System
System Overview

The Continuous Particulate Matter Emission Monitoring System consists of three basic components: the particulate matter monitoring unit (dust), the flue gas parameter monitoring unit (temperature, pressure, flow rate, O2, humidity), and the data acquisition and processing unit.

Smoke and dust are extracted into the measurement chamber through high-temperature heating. The embedded high-stability laser light source irradiates the smoke particles, and the intensity of the laser scattering signal is positively correlated with the concentration of the smoke particles being irradiated. The instrument detects the weak light scattering signals (intensity signals and pulse signals), and through specific algorithms, calculates the concentration of smoke and dust.

Key Features
  • LCD display for direct reading of dust concentration
  • Extractive laser forward scattering design, unaffected by operating conditions
  • High precision, good stability, and fast response time of the sensor
  • Single-end installation with automatic dual-range switching and low detection limit
  • Modular design with fault alarm codes for easy maintenance and repair
  • Supports RS485/standard analog output and local dynamic regulatory control
Operating Principle

Optical Section: The optical system comprises a laser light source, power control unit, photoelectric sensing module, and scattered light reception unit. A 650 nm laser beam is emitted at a slight angle into the emission source. The interaction between the laser beam and smoke/dust particles generates scattered light, with backscattered light entering the sensor through the reception system and being converted into electrical signals for processing.

Circuit Section: Implements functions including photoelectric conversion, laser beam modulation, signal amplification, demodulation, light source power control, V/I conversion, and HMI display. The calibrator generates stable optical signals to perform zero-point calibration and range calibration for the instrument.

Technical Parameters
Parameter Specification
Dimensions & Weight Φ158*275 mm / 5 kg
Environmental Requirements Temperature: -40ºC to 65ºC
Humidity: 0-100% RH
Measurement Error ±2% FS
Media Conditions Temperature: Up to 300ºC
Customizable for higher temperatures
Display 128*64 Graphic LCD
Signal Output (4-20) mA
Maximum Load 500 Ω
Sensitivity 2 mg/m³
Measurement Range Low: 0-50 mg/m³
High: 0-10 g/m³
Customizable ranges available
Applicable Stack Size 1-15 m
Power Consumption 3 W
Power Supply DC 24 V ±10%