High Recovery Rate Electrodeionization Module For Reverse Osmosis RO System
EIMD-30SP Electrodeionization Module With High Recovery Rate Resilient To Water Quality Fluctuations And Low Operating Costs High recovery rate electrodeionization module resilient to water quality fluctuations with low operating costs. EIMD-SP Modules Overview The Aquacells EIMD-SP module is tailor-made for the effluent from a single-stage reverse osmosis (RO) system. It demonstrates resilience to fluctuations in water quality and significantly reduces both investment and
High recovery rate electrodeionization module resilient to water quality fluctuations with low operating costs.
The Aquacells EIMD-SP module is tailor-made for the effluent from a single-stage reverse osmosis (RO) system. It demonstrates resilience to fluctuations in water quality and significantly reduces both investment and operating costs.
| Parameter | Specification |
|---|---|
| FCE (including CO2 and Silica) | < 80 µS/cm |
| Feed Water Source | Condensate water |
| Temperature | 5-45 ℃ (40-113 ℉) |
| Feed pressure | 1.4-7 bar (20-100 psi) |
| Total Chlorine (as CI2) | <0.05 ppm |
| Fe | <0.01 ppm |
| Mn | <0.01 ppm |
| S2- | <0.01 ppm |
| pH | 4-11 |
| Total Hardness (as CaCO3) | <1.0 ppm |
| Dissolved Organics (TOC as C) | <0.5 ppm |
| Silica (SiO2) | <1.0 ppm |
| Parameter | Specification |
|---|---|
| Typical Recovery | >85% |
| Maximum Feed Pressure | 7 bar (100 psi) |
| Maximum Feed Temperature | 45 ℃ (113 ℉) |
| Minimum Discharge pressure | > 1 bar |
| DC Voltage* | 0-300 V |
| DC Amperage | 0-6 A |
| Product Resistivity | >10 MΩ·cm |
| Silica (SiO2) Removal | 90-99% depending on feed water |
*Voltage required depends on module size