API 661 Forced Draft Air Cooled Exchanger for Petroleum

API 661 Forced Draft Air Cooled Exchanger for Petroleum Forced Draught Air Cooled Heat Exchanger with API 661, Petroleum Industry Need a custom quote for Air Cooled Exchangers? Contact our engineering team directly: [email protected] Selection of Induced Draught or Forced Draught The air-cooled heat exchanger shall be either a forced-draught exchanger or an induced-draught exchanger and shall include the components shown in Figure 1 and any auxiliaries such as

Brand Name YUHONG
Payment Terms L/C,T/T
Place of Origin China
Price 2000 ~ 10M USD
Delivery Time 45-150 DAYS
Minimum Order Quantity 1 SET
Product Description
API 661 Forced Draft Air Cooled Exchanger for Petroleum
Forced Draught Air Cooled Heat Exchanger with API 661, Petroleum Industry
Need a custom quote for Air Cooled Exchangers? Contact our engineering team directly: [email protected]
Selection of Induced Draught or Forced Draught
The air-cooled heat exchanger shall be either a forced-draught exchanger or an induced-draught exchanger and shall include the components shown in Figure 1 and any auxiliaries such as ladders, walkways and platforms. Forced-draught fans should be used, except that induced-draught fans should be considered for the following situations:
  • If temperature control of the process is critical and sudden downpour of rain (i.e. excessive cooling) can cause operating problems
  • To minimize the risk of hot-air recirculation
  • On sites where air-side fouling is a significant problem, however forced draft can be used if screens are specified
  • To improve thermal performance in the event of a fan failure (due to the stack effect)
  • In hot climates, where the fan plenum chamber shields the bundle from the sun
  • For services that have a temperature approach of 11 °C (20 °F) or less
Forced Draught and Induced Draught Air Cooled Heat Exchanger configurations
Figure 1: Forced Draught vs Induced Draught Configurations
A) Forced Draught B) Induced Draught
1 - Tube Bundle 6 - Fan
2 - Header 7 - Fan Ring
3 - Nozzle 8 - Fan Deck
4 - Supporting Column 9 - Drive Assembly
5 - Plenum 10 - Fan Guard
Construction of Tube Bundle
Tube bundles shall be rigid, self-contained, and designed for handling as a complete assembly.
Removable cover-plate header construction
A) Removable cover-plate header
Removable bonnet header construction
B) Removable bonnet header
Typical Construction of Tube Bundles
1 Tubesheet
2 Removable cover plate
3 Removable bonnet
4 Top and bottom plates
5 Tube
6 Pass partition
7 Gasket
8 Nozzle
9 Side frame
10 Tube spacer
11 Tube support cross-member
12 Tube keeper
13 Vent
14 Drain
15 Instrument connection
Tubes and Finning
Maximum Fin Selection Temperature for Fin Bonding Types:
Fin Bonding Type Maximum Process Temperature °C (°F)
Embedded fins 400 (750)
Externally bonded (hot-dip galvanized steel fins) 360 (680)
Extruded fins 300 (570)
Footed fins (single L) & overlap footed fins (double L) 130 (270)
Knurled footed fin, either single L or double L 200 (390)
Externally Bonded (welded or brazed fins) > 400 (750) (maximum should be negotiated)
Tubes and finning construction details
Tubes and Finning Construction

Recommended Products

China Forced Draft Air Cooled Heat Exchangers API 661 Design Power Plant Application for sale Video
China API 661 Air Cooled Heat Exchanger Forced Draft Fin Fan Cooler for Boiler Feed Water for sale Video
China ASME U Stamp Air Cooled Heat Exchanger Forced Draft Fin Fan Cooler (SA249 TP304L) for sale Video
China Horizontal Forced Draft Air Cooler for Refinery Reactors for sale Video
Price: 2000 ~ 10M USD