Conventional 2 Zone Fire Alarm Panel with 30 Detectors per Zone and 2A Relay Rating for EN54 Compliant Systems

EN54-compliant conventional fire alarm panel featuring 2 zones supporting 30 detectors each, RS485 connectivity, and external device control outputs. Compact 370x440x100mm metal enclosure with backup battery support. Includes 1-year warranty and comprehensive technical support for reliable fire safety systems.

Place of Origin China
Types of Smoke Detectors Photoelectric Smoke Detector
Connected Wired Conventional 2 zone Smoke alarm panel
Packaging Details 370mm*440mm*100mm
Power supply 90-270VAC
Model Number XHA1002
Product Description
Conventional 2 Zone Fire Alarm Panel
Conventional 2 Zone Fire Alarm Panel front view and components
Product Overview
This conventional 2 zone fire alarm panel is designed to meet EN54 Parts 2 & 4 standards, providing advanced fire detection capabilities with straightforward operation and efficient installation. The system supports comprehensive integration with optical, ionization, photoelectric, photoelectric-thermal, and heat detectors, ensuring full compatibility across all system components.
Key Features
  • 2 conventional input zones supporting up to 30 detectors per zone
  • External device control outputs for bells, sirens, flame detectors, and beam detectors
  • Dedicated alarm and trouble relays for enhanced safety monitoring
  • RS485 communication interface for panel connectivity
  • Compact metal enclosure: 370mm W x 440mm H x 100mm D
  • Supports 12V, 2.3Ah backup batteries for reliable operation
  • Can operate independently or connect via RS485 network
Technical Specifications
Parameter Specification
Primary AC Power 120VAC 50/60 Hz or 240VAC 50/60 Hz
Power Supply Rating 2 Amps @ 24VDC
Maximum Battery Charging Current 0.90 Amps @ 26VDC
Initiating Device Circuits Alarm Zone 2/4/8/16
Normal Initiating Operating Voltage 22VDC, Maximum 26VDC, regulated
Normal Monitor Current <50mA
Alarm Current <150 mA
Maximum Detector Count per Zone 30 detectors
Initiating Cabling Type 18AWG Twisted Shielded pair (14 - 18 AWG)
Relay Ratings 2A & 30VAC, resistive (Fault & Alarm)
System Connection Diagram
Conventional 2 Zone Fire Alarm Panel connection diagram and wiring schematic