China Three Phase Stationary Power Source 288V 100A for Utility Meter Testing for sale
China Three Phase Stationary Power Source 288V 100A for Utility Meter Testing for sale

Three Phase Stationary Power Source 288V 100A for Utility Meter Testing

High-accuracy three-phase stationary power source for power utilities and meter manufacturers. Features 2nd-21st harmonic programmability, RS232 automation, and rugged aluminum enclosure. Offers voltage up to 288V and current up to 100A with 0.05% accuracy and 0.005%/h stability.

Place of Origin CHINA
Relative Humidity 35% – 85% (non-condensing)
Packaging Details Plywood cases
Input Voltage 3 × 220 V / 380 V ±10% or customized
Model Number YCSS-103
Supply Ability 10 pcs/ 1 months
Product Description
Three-Phase Stationary Power Source for Power Utilities and Meter Manufacturers
High-Accuracy Three-Phase Stationary Power Source
Professional-grade power source designed specifically for power utilities and meter manufacturers, delivering exceptional accuracy and reliability for testing applications.
Key Features
  • High accuracy with excellent long-term output stability
  • RS232 communication interface supporting automated operation
  • Optional built-in keyboard for convenient manual operation
  • Harmonics from 2nd to 21st order freely programmable in amplitude and phase angle
  • Rugged aluminum alloy enclosure: lightweight, high strength, and corrosion-resistant
  • User-friendly PC control software for easy operation and system integration
  • Comprehensive protection functions including overload, short-circuit voltage, and open-circuit current protection
Technical Specifications
Voltage Output
Parameter Specification
Test Voltage (Phase-Neutral) 3 × (24 V - 288 V) or customized
Voltage Output Power 3 × 100 VA, 3 × 250 VA, 3 × 500 VA, 3 × 1000 VA
Resolution Better than 0.01% of full-scale range
Setting Accuracy Better than 0.05% of final range value
Stability Better than 0.005%/h (integration time: 150 s)
Load Regulation (0 to Max Load) < 0.01%
Distortion Factor < 0.3% (linear resistive load)
Harmonics 2nd - 21st, freely programmable
Current Output
Parameter Specification
Test Current Range 3 × (1 mA - 100 A)
Current Output Power 3 × 150 VA, 3 × 350 VA, 3 × 750 VA, 3 × 1500 VA
Resolution Better than 0.01% of full-scale range
Setting Accuracy Better than 0.05% of final range value
Stability Better than 0.005%/h (integration time: 150 s)
Load Regulation (0 to Max Load) < 0.01%
Distortion Factor < 0.3% (linear resistive load)
Harmonics 2nd - 21st, freely programmable
Three-Phase Stationary Power Source unit for power utilities and meter testing applications
Interested in this product?
Contact us now for more details and a custom quote.