Full Automatic Three Phase Meter Test Bench with ICT - 24 Positions, 0.05% Accuracy, 3x100A Current Output

Professional three-phase meter test bench with 24 positions and 0.05% accuracy. Features automatic testing for mechanical and electronic meters, 3x100A current output, ICT isolation technology, and comprehensive software support. Ideal for energy meter manufacturers, utilities, and testing laboratories requiring high-precision metrology equipment.

Relative humidity 35%~85%
Frequency Range 45Hz~65Hz
Place of Origin CHINA
Packaging Details Plywood case
Model Number YC1893D
Accuracy class Class 0.02/0.05
Product Description
Full Automatic Three Phase Meter Test Bench With ICT

Advanced metrology system for comprehensive testing of three-phase energy meters with integrated ICT (Isolated Current Transformer) technology.

Product Overview

GENY meter test systems utilize state-of-the-art electronic metrology and modular architecture, integrating precision reference standards with high-stability power amplifiers. Designed to meet the demanding requirements of energy-meter manufacturers, power utilities, metrology laboratories, inspection authorities, and industrial test facilities.

Key Features
  • Tests Ferraris (mechanical), electro-mechanical and fully electronic meters
  • Automatic, semi-automatic or manual operation modes
  • Parallel testing for meters with identical specifications but different k-values
  • Multiple wiring configurations: 3P4W, 3P3W, 1P2W
  • Automatic disc-mark alignment for Ferraris meters increases throughput
  • Comprehensive test quantities including active energy, reactive energy, cross-reactive energy
  • Optional neutral-current test for tamper detection
  • Starting and no-load (creep) tests included
  • Optional ICT isolates current and voltage circuits on three-phase meters with internal I-P links
  • Overload, short-circuit and open-circuit protection
  • Corrosion-resistant aluminium alloy frame construction
  • Synchronised scan heads fold together for quick change-over
  • Windows-based test software (7/8/10) covering error, harmonic, maximum demand and influence tests
  • Data export to CSV, PDF and XML formats
Technical Specifications
Specification Details
Number of meter positions 24
Accuracy 0.05 / 0.02
Power Source YCS-103-1200
Standard Meter SZ03A-K6 / SZ03A-K8 / Radian RD-33
Scanning Head YCG-S Series
Test voltage output (Phase-Neutral) 3* (24V~288V) (or customized)
Power of voltage output Max. 3x500VA
Test current output 3* (1mA - 100A)
Power of current output Max. 3x750VA
Phase angle range 0~360°
Frequency range 45Hz~65Hz
Voltage supply 3x220/380V±10% (or customized) 50/60Hz ±2Hz
Ambient temperature -10°C~+40°C
Relative humidity 35%~85%