YC1891D Series Multi-Function Energy Meter Test Bench with 0.05% Accuracy, 24V-288V Voltage & 1mA-100A Current Range
Professional energy meter test bench with 0.05% accuracy for mechanical, electromechanical, and electronic meters. Features 6-48 meter positions, 24V-288V voltage output, 1mA-100A current range, and Windows-compatible software. Supports active/reactive power testing, harmonic analysis, and comprehensive protection functions.
The YC1891D Series Multi-Function Energy Meter Test Bench is a comprehensive testing solution designed for various energy meter types including mechanical, electromechanical, and electronic meters. This advanced system supports multiple operation modes and testing functions to ensure accurate meter calibration and verification.
- Tests single-phase two-wire (1P2W) meters with active power, reactive power, and cross-connected reactive power measurement capabilities
- Equipped with Multi-Functional Standard Voltage Transformer (MSVT) for testing meters with closed I-P links
- Current output switch enables calibration of two-element meters (optional)
- Simultaneous testing of meters with different specifications and meter constants
- Automatic rotor mark location on mechanical meter discs for improved efficiency
- Comprehensive protection against overload, short-circuited voltage circuits, and open-circuited current circuits
- Synchronous scanning head swinging simplifies control processes
- Durable aluminum alloy construction providing lightweight strength and corrosion resistance
- Windows-compatible software (2000/XP/7/8/10) with complete functional modules for error tests, harmonic tests, demand tests, and influence tests
| Model | YC1891D-6 | YC1891D-12 | YC1891D-24 | YC1891D-48 |
|---|---|---|---|---|
| Number of meter positions | 6 | 12 | 24 | 48 |
| Power Source | YCS-101-250 | YCS-101-600 | YCS-101-1200 | YCS-101-2500 |
| MSVT | HJ200GL-6 | HJ200GL-12 | HJ200GL-24 | HJ200GL-48 |
| Voltage Output Power | 100VA | 250VA | 500VA | 1000VA |
| Current Output Power | 150VA | 350VA | 750VA | 1500VA |
| Parameter | Specification |
|---|---|
| Accuracy | 0.05% |
| Test Voltage Output | 24V - 288V or customized |
| Test Current Output | 1mA - 100A or customized (Max. 200A) |
| Resolution | Better than 0.01% of full scale value |
| Setting Accuracy | Better than 0.05% at final range value |
| Frequency Range | 45Hz - 65Hz |
| Phase Angle Range | 0 - 360° with 0.01° resolution |
| Ambient Temperature | -10°C to +40°C |
| Relative Humidity | 35% - 85% |