China Electromagnetic Flow Meter DN3 to DN3000mm with ±0.5% Accuracy and 1500:1 Range for Conductive Liquids for sale
China Electromagnetic Flow Meter DN3 to DN3000mm with ±0.5% Accuracy and 1500:1 Range for Conductive Liquids for sale
China Electromagnetic Flow Meter DN3 to DN3000mm with ±0.5% Accuracy and 1500:1 Range for Conductive Liquids for sale
China Electromagnetic Flow Meter DN3 to DN3000mm with ±0.5% Accuracy and 1500:1 Range for Conductive Liquids for sale
China Electromagnetic Flow Meter DN3 to DN3000mm with ±0.5% Accuracy and 1500:1 Range for Conductive Liquids for sale
China Electromagnetic Flow Meter DN3 to DN3000mm with ±0.5% Accuracy and 1500:1 Range for Conductive Liquids for sale

Electromagnetic Flow Meter DN3 to DN3000mm with ±0.5% Accuracy and 1500:1 Range for Conductive Liquids

Precision electromagnetic flow meter with DN3 to DN3000mm diameter range, ±0.5% accuracy, and 1500:1 measuring ratio. Features no moving parts, corrosion-resistant materials, and bidirectional flow measurement. Ideal for water supply, chemical, and industrial applications requiring reliable conductive liquid monitoring.

Medium Conductivity ≥20μs/cm
Place of Origin China
Packaging Details carton、50cm*50cm*100cm
Lining Material PTFE, PFA, F46, neoprene rubber, polyurethane rubber, high-temperature rubber, etc.
Nominal Diameter DN3 to DN3000mm
Model Number DX-EMF
Product Description
Electromagnetic Flow Meter for Precise Volumetric Measurements
The electromagnetic flowmeter is an induction-based instrument designed for measuring volumetric flow of conductive liquids. It provides real-time monitoring with display capabilities and outputs standard current signals for recording, regulation, and automated control systems.
Technical Specifications
Parameter Specification
Nominal Diameter DN3 to DN3000mm
Accuracy ±0.5% (options for ±0.3% or ±0.2%)
Lining Materials PTFE, PFA, F46, neoprene rubber, polyurethane rubber, high-temperature rubber
Electrode Materials SUS316, Hastelloy B/C, titanium, tantalum, platinum-iridium alloy, tungsten carbide coated
Medium Temperature -20℃ to 180℃
Nominal Pressure 0.6 to 4.0Mpa (customizable)
Measuring Range 1500:1 ratio, flow rate <15m/s
Protection Grade IP65, IP68 (optional)
Working Principle

Based on Faraday's law of electromagnetic induction, the flowmeter operates by detecting electrodes installed perpendicular to both the tube axis and magnetic lines. As conductive liquid flows through the measurement tube, it cuts magnetic lines, generating an induced electromotive force proportional to flow velocity.

E = KBVD
Where:
E - Induced electromotive force
K - Magnetic field distribution coefficient
B - Magnetic induction strength
V - Average liquid velocity
D - Electrode distance (tube diameter)
Key Features
  • Simple sensor structure with no moving parts for unobstructed fluid flow
  • Capable of measuring dirty, corrosive, and suspended solid-liquid media
  • Accuracy unaffected by temperature, viscosity, density, or conductivity variations
  • Output proportional only to average velocity, independent of flow profile
  • Fast response with no mechanical inertia, suitable for pulsating flow
  • Bidirectional flow measurement capability
  • Wide size range from DN3 to DN3000mm
Applications

Water supply systems, chemical processing, coal industry, environmental protection, light industry, metallurgy, paper manufacturing, and other industries requiring precise conductive liquid flow measurement.

Interested in this product?