China TD1600 Fluke Multifunction Calibrator High Precision Single Phase AC Calibrator for sale
China TD1600 Fluke Multifunction Calibrator High Precision Single Phase AC Calibrator for sale

TD1600 Fluke Multifunction Calibrator High Precision Single Phase AC Calibrator

TD1600 Precision AC Calibrator Introduction TD1600, a single-phase AC calibrator with wide range, high precision and multifunction. The apparatus can output high accuracy AC voltage, current and power, and the optional accuracy are 0.05% and 0.02%. Applied to calibrate various AC electrical measuring instruments. Features AC Electrical Parameter Output: Voltage is up to 1100 V, current is up to 110 A. Frequency and Phase Adjustment: Frequency: 45 Hz ~ 70 Hz. AC Power Output:

Origin China
Place of Origin China
Packaging Details Standard
Model Number TD1600
Name Fluke Multifunction Calibrator
Brand Name TUNKIA
Product Description
TD1600 Precision AC Calibrator
 

Introduction

  • TD1600, a single-phase AC calibrator with wide range, high precision and multifunction.

  • The apparatus can output high accuracy AC voltage, current and power, and the optional accuracy are 0.05% and 0.02%. Applied to calibrate various AC electrical measuring instruments.

Features

  • AC Electrical Parameter Output: Voltage is up to 1100 V, current is up to 110 A.

  • Frequency and Phase Adjustment: Frequency: 45 Hz ~ 70 Hz.

  • AC Power Output: Measure the active power, reactive power, apparent power and power factor.

  • Value Output Mode: Standard source and output source modes, easy to calibrate both digital meters and analogue meters.

  • Value Adjustment Method: Fixed-point, rotary encoder, step and potentiometer (option).

  • Output Switch: The output can be turned on/off arbitrarily by one-touch operation.

  • Automatical Error Calculation: Set the measured values of the checked meter, and adjust the value output to automatically calculate the errors of the checked meter.

  • Excellent Human-computer Interaction: Large LCD touch screen display, touch and button operation modes, easy for users to measure manually.

  • Harmonic (Option): Load 2nd to 31st harmonics with variable amplitude and phase for impact test.

  • Proprietary Software (Option): Support the calibration of the checked meters by semi-automatic or full-automatic, data management and report export.

 

Specification

 

AC Voltage Output

Range Stability (%/min)

Accuracy (k = 2)

(ppm*RD + ppm*RG)

Max. Load Current

(mA)

0.05% 0.02% 0.05% 0.02%
1 V 0.01 0.005 300 + 200 120 + 80 500
3 V 0.01 0.005 300 + 200 120 + 80 500
10 V 0.01 0.005 300 + 200 120 + 80 500
30 V 0.01 0.005 300 + 200 120 + 80 500
60 V 0.01 0.005 300 + 200 120 + 80 800
100 V 0.01 0.005 300 + 200 120 + 80 500
150 V 0.01 0.005 300 + 200 120 + 80 400
200 V 0.01 0.005 300 + 200 120 + 80 250
300 V 0.01 0.005 300 + 200 120 + 80 150
400 V 0.01 0.005 300 + 200 120 + 80 100
600 V 0.01 0.005 300 + 200 120 + 80 80
750 V 0.01 0.005 300 + 200 120 + 80 60
1000 V 0.01 0.005 300 + 200 120 + 80 50

 

 

AC Current Output

Range Stability (%/min)

Accuracy (k = 2)

(ppm*RD + ppm*RG)

Max. Inductive

Load (V)

0.05% 0.02% 0.05% 0.02%
1 mA 1 μA 0.5 μA 300 + 2 μA 120 + 1 μA 120
2 mA 1 μA 0.5 μA 300 + 2 μA 120 + 1 μA 120
5 mA 1 μA 0.5 μA 300 + 2 μA 120 + 1 μA 120
10 mA 0.01 0.005 300 + 200 120 + 80 120
20 mA 0.01 0.005 300 + 200 120 + 80 120
50 mA 0.01 0.005 300 + 200 120 + 80 120
100 mA 0.01 0.005 300 + 200 120 + 80 120
200 mA 0.01 0.005 300 + 200 120 + 80 120
500 mA 0.01 0.005 300 + 200 120 + 80 100
1 A 0.01 0.005 300 + 200 120 + 80 50
2 A 0.01 0.005 300 + 200 120 + 80 25
5 A 0.01 0.005 300 + 200 120 + 80 10
10 A 0.01 0.005 300 + 200 120 + 80 5
20 A 0.01 0.005 300 + 200 120 + 80 2.5
30 A 0.01 0.005 300 + 200 120 + 80 2.5
50 A 0.01 0.005 300 + 200 120 + 80 1.5
100 A 0.01 0.005 300 + 200 120 + 80 0.8

 

Output Characteristics of Voltage and Current

  • Output Range of Voltage: 100 mV ~ 1100 V

  • Output Range of Current: 0.1 mA/ 20 mA ~ 110 A

  • Range Switching: Automatic or Manual.

  • Resolution: 0.001 %*RG; Display: 6 digits; Distortion: <0.2 %

  • 1 mA,2 mA,5 mA are small range option.

 

Frequency, Phase and Harmonic (Option)

Type Range Resolution Accuracy
Frequency 45.000 Hz ~ 70.000 Hz 0.001 Hz 0.005 Hz
Phase 0.0000 ° ~ 359.9999 ° 0.005 ° 0.05 °
Type Order Amplitude Variable Phase
Harmonic 2nd to 31st 0 ~ 25 % 0 ~ 359.9 °

 

Power Output

Type Stability (%/min) Accuracy (k = 2) %*FS
0.05% 0.02% 0.05% 0.02%
Active Power 0.01 0.005 0.05 0.025
Reactive Power 0.02 0.01 0.1 0.05
Apparent Power 0.02 0.01 0.1 0.05
Power Factor 0.02 0.01 0.1 0.05
  • Output Range of AC Power: Combination of AC voltage range and AC current range.

  • Range of Power Factor: -1.0000…0.0000…+1.0000

  • Active Power (|cosφ| ≥0.5), Reactive Power (|sinφ| ≥0.5)

Interested in this product?
Contact us now for more details and a custom quote.