China Programmable IEC Temperature Humidity Chamber PTH-1000 150L -40℃ to +150℃ ±0.2℃ Precision for sale
China Programmable IEC Temperature Humidity Chamber PTH-1000 150L -40℃ to +150℃ ±0.2℃ Precision for sale

Programmable IEC Temperature Humidity Chamber PTH-1000 150L -40℃ to +150℃ ±0.2℃ Precision

Professional IEC60335-2-17 compliant programmable temperature humidity chamber with 150L capacity, operating range -40℃ to +150℃ and 20%RH to 98%RH. Features ±0.2℃ temperature precision, ±2.5%RH humidity control, and rapid heating/cooling rates for accurate fabric aging tests.

Place of Origin China
Packaging Details safety wooden box
humidity range 20 %RH~ 98 %RH
type chamber
Supply Ability 5 sets per month
Certification calibration certificate
Product Description
Programmable IEC Test Equipment
IEC60335-2-17 Programmable Temperature Humidity Chamber

This programmable temperature humidity chamber model PTH-1000 (150L) operates within a temperature range of -40℃ to +150℃ and humidity range of 20%RH to 98%RH, designed specifically for compliance testing according to IEC60335-2-17 standards.

Technical Specifications
Parameter Specification
Working Volume 150L (customizable)
Inner Dimensions W500mm × H600mm × D500mm
Outer Dimensions W1020mm × H1000mm × D1460mm
Weight 300KG
Temperature Range -40℃ to +150℃
Temperature Control Precision ±0.2℃
Humidity Range 20%RH to 98%RH
Humidity Control Precision ±2.5% RH
Temperature Uniformity ±2℃
Humidity Uniformity ±3.0% RH
Heating Rate 3℃/min (average)
Cooling Rate 1℃/min (average)
Power Requirements AC 1∮ 220V 50Hz MAX 40A
Application & Standards

This equipment is specifically designed for aging tests on blanket's flexible fabric parts, ensuring compliance with:

  • IEC60335-2-17, Clause 21.110.3, Clause 21.111.2
  • Test methods according to IEC60068-2 and IEC60598-1
Performance Notes
Temperature and humidity control accuracy: ±0.2℃; ±2.5%RH. To guarantee performance, measurements should be taken 30 minutes after temperature sensing stabilizes.
Temperature and humidity distribution uniformity: ±2℃; ±3%RH. Measuring positions should be at each wall's 1/6 positions of the test zone, taken 30 minutes after temperature stabilization.
Sample volume should not exceed 2/3 of the test zone capacity to ensure accurate testing conditions.
Reference Images
Temperature humidity chamber humidity use range chart Programmable IEC temperature humidity test chamber equipment
Interested in this product?
Contact us now for more details and a custom quote.