China Reactive Power Auto Compensation Controller for sale
China Reactive Power Auto Compensation Controller for sale

Reactive Power Auto Compensation Controller

Home Spare parts JKW18 Intelligent Reactive Compensation Controller Reactive Power Auto Compensation Controller JKW18 Intelligent Reactive Compensation Controller JKW18 series intelligent low voltage reactive auto compensation controller are used for measurement and control of power factor control units for centrlaoyu al reactive power compensation. The POWER FACTOR measured by JKW18 is compared with the set point values and in order to provide necessary compensation , Power

Operating Voltage Range: (0.9-1.1)x Un
Rated Current(In): …./5A
Place of Origin China
Packaging Details Standard export packaging
Phase –Neutral Connection Voltage 220,230,240 VAC
Model Number JKW18
Product Description
Home Spare parts JKW18 Intelligent Reactive Compensation Controller
Reactive Power Auto Compensation Controller

JKW18 Intelligent Reactive Compensation Controller

JKW18 series intelligent low voltage reactive auto compensation controller are used for measurement and control of power factor control units for centrlaoyu al reactive power compensation. The POWER FACTOR measured by JKW18 is compared with the set point values and in order to provide necessary compensation , Power Factor Controller switches capacitor banks ON and OFF automatically
Inquire

Product Introduction

Technical Data:

Rated Voltage (Un): 220,230,240 VAC (Phase –Neutral Connection )
380,400,415 VAC(Phase-Phase Connection)
Operating Voltage Range: (0.9-1.1)x Un
Rated Current(In): …./5A
Operating Current Range: (0.91-1.1) X In
Rated power: Voltage: 3VA-10VA
Output Contact: 3A, 750 VA (NO Contact)
No-Voltage Feature: in case of power failure longer than 200 msec. all capacitor steps are disconnected automatically .
Setting Range: C/K:0.02-1.0 Steps: 1-12 COS :0.85(ind.)-1.00
CTR:5-6000 Time:2-50 sec, Program:PS1-PS5
Over Voltage: 220-260V(380V-500V)
Factory Set Value: COS=1.00(ind.),Step =12 ,Time=7(sec)
Program=PS1, C/K=0.05, CTR=500
Over voltage:240v/430v
Ambient Temperature: -25degree -55degree.
Display: 4 Digit, Red Display.
Equipment Protection Class: Double Insulation- Class II
Wire Section (For Terminal Block): 2.5mm2
Terminal Block Protection Class: IP 00
Protection Class: IP 20
Connections: Socket terminal with screw
Dimension : Type PR16
Switchboard Cut-out : 139X139MM
Weight: 0.8kg

Recommended Products

Price: Negotiable
Price: Negotiable
Price: Negotiable
Price: Negotiable
Price: Negotiable
Interested in this product?
Contact us now for more details and a custom quote.