Two Phase Liquid Cooling Immersion Cryptocurrency Cooler

Two-phase Liquid Cooling Liquid Immersion Cooling Systems For Cryptocurrency Mining Farms What's Immersion Cooling? Also known as liquid submersion cooling. It is the practice of submerging computer components (or full servers) in a thermally, but not electrically, conductive liquid (dielectric coolant) allowing higher heat transfer performance than air and many other benefits. Why many large data centers have already moved or are considering the move to immersion cooling? 1.

Place of Origin China
Packaging Details Stretch film and Pallet for full container loading
Media Electrocool dielectric coolants
Power supply 380V/3P/50Hz or 380V/3P/60Hz
Model Number SHSL-D1 Series
Fin material Hydrophilic aluminum foil or epoxy resin aluminum foil
Product Description

Two-phase Liquid Cooling Liquid Immersion Cooling Systems For Cryptocurrency Mining Farms

 

What's Immersion Cooling?

Also known as liquid submersion cooling. It is the practice of submerging computer components (or full servers) in a thermally, but not electrically, conductive liquid (dielectric coolant) allowing higher heat transfer performance than air and many other benefits.

Why many large data centers have already moved or are considering the move to immersion cooling?

 

1. Up to 25% increase in power efficiency
2. Up to 80% cost reduction
3. Up to 60% hashrate increase
4. 50%+ equipment lifespan.

 

Introduction of Two-phase Liquid Cooling:

    The cooling liquid undergoes a phase change in the process of circulating heat dissipation. The cooling liquid takes away the heat from the server and then undergoes a phase change gasification. The gaseous cooling liquid is condensed by the condenser and becomes liquid again and returns to the liquid cooling tank; the cooling liquid can use 3M electronics The boiling point of the coolant FC-72 and FC-72 is above 50℃.
In this case, the temperature of the water in the condensing coil does not need to be too low. The use of a dry cooler can meet the heat exchange requirements and take away the heat.
    The two-phase liquid cooling has a high heat transfer efficiency due to the phase change of the electronic cooling liquid.
    The disadvantage is that during this phase change, the electronic fluorinated liquid will escape during the vaporization process, so there is a certain degree of tightness of the container. However, it should not be too sealed to prevent the cooling system from being interrupted and the cylinder explosion event, so certain safety facilities need to be set up.

Technical parameter

Dry cooler D1 series parameter (fin space 2.1mm)

Type

D1-005-

1x350

D1-006-

1x350

D1-007-

1x350

D1-009-

1x450

D1-011-

1x450

D1-013-

1x450

D1-014-

1x500

D1-017-

1x500

D1-020-

1x500

Capacity Water 35℃ outdoor temp. Inlet 45℃ KW 4.89 5.9 6.83 9.39 10.99 13.33 14.32 17.01 19.8
outlet 40℃ Y
20% Glycol Inlet 45℃ 4.72 5.69 6.69 8.9 10.61 13.05 13.91 16.11 19.29
outlet 40℃ Y
Medium Water flow M3/h 0.85 1.03 1.2 1.63 1.91 2.3 2.5 3 3.5
Pressure drop kPa 36 31 58 25 40 80 50 60 40
Air flow M3/h 2828 2712 2492 6199 5827 5225 8469 8168 7601
Y
Fan motor Phase 1 1 1 3 3 3 3 3 3
W 140 140 140 540 540 540 830 830 830
Y
A 0.6 0.6 0.6 1.1 1.1 1.1 1.45 1.45 1.45
Y
Fan No X φ 1x1x350 1x1x350 1x1x350 1x1x450 1x1x450 1x1x450 1x1x500 1x1x500 1x1x500
Sound pressure level dB(A) 31 31 31 43 43 43 49 49 49
Y 10m
Dimension L mm 870 870 870 1020 1020 1020 1220 1220 1220
W mm 525 525 525 625 625 625 825 825 825
H mm 797 797 797 820 820 820 870 870 870
A mm 690 690 690 840 840 840 1040 1040 1040
B mm -- -- -- -- -- -- -- -- --
C mm -- -- -- -- -- -- -- -- --
D mm 490 490 490 490 490 490 490 490 490
Inlet φ mm 3/4” 3/4” 3/4” 1” 1” 1” 1-1/4” 1-1/4” 1-1/4”
Inlet φ mm 3/4” 3/4” 3/4” 1” 1” 1” 1-1/4” 1-1/4” 1-1/4”
Product weight(empty) kg 38 42 48 55 60 67 75 82 91

Note: Standard SHSL-D1 dry cooler is vertical air discharge, for horizontal air discharge please add “H” in nomenclature, for excmple:SHSL-D1-005H-1X350

 

Some data center cooling reference:

 

For data center cooling:

Country: Mongolia

Application: match with precision air conditioner

Cooling capacity: 17.6kW

Cooling medium: 34% ethylene glycol

Supply power: 400V/3P/50Hz

Fan brand: Ziehl-Abegg

Country: Russia

Application:data center cooling

Cooling capacity: 763kW

Cooling medium: water

Supply power: 380V/3P/50Hz

Fan brand: Ziehl-Abegg

 

 

The immersion cooling system diagram by dry cooler/dry cooling tower:

Recommended Products

China High Density Servers Cryptocurrency Miners Immersion Bitcoin Cooling System for sale Video
Price: 655~32005 USD per unit
China Adiabatic Dry BTC Bitcoin Cooling System Anti Corrosion for sale Video
Price: 660~30000 USD per unit
China TurnKey Solution Hydrophilic Fin Copper Tubes Air Dry Crypto Mining Cooler for sale Video
Price: 590~32000 USD per unit
China Wet-Dry Coolers Direct Water Spray Two Phase Liquid Bitcoin Cooling System for sale Video
China Submerging Bitcoin Miners Two Phase Immersion Cooling Dry Coolers for sale Video
Price: 560~31005 USD per unit
China Flat Type High Heat Transfer Efficiency Immersion Bitcoin Cooling System for sale Video
Price: 5999~50000 USD per unit
China Gold Fin Adiabatic Dry Cooler Crypto BTC Cooling System for sale Video
Price: 660~30000 USD per unit
China Blockchain Miners Copper Tubes Bitcoin Cooling System Electrolyte Liquid for sale Video
Price: 560~31005 USD per unit
Interested in this product?
Contact us now for more details and a custom quote.