IGBT Electroplating Rectifier 200A 24V
has a long history in chemical industry. It is an electrolyzer with two electrodes operating in a liquid alkaline electrolyte of potassium hydroxide (KOH) or sodium hydroxide (NaOH). These electrodes are separated by a diaphragm to separate the product gas and transfer the hydroxyl ion (OH -) from one electrode to the other. The comparison results show that the most advanced nickel based water
IGBT electroplating rectifier 200A 24V
24V 200A alkaline water electrolysis power supply Specification
| SPECIFICATIONS FOR GKD24-200CVC | |||
| Input AC | 220V±10% | 1 phase | 50/60Hz |
| Output DC | Volt | 0~24V Adjustable | |
| Current | 0~200A Adjustable | ||
| Power | 4.8KW | ||
| Efficiency | >85% | ||
| output Frequency | 40KHz fixed | ||
| output ripple | 3% | ||
| Protection | Short circuit protection Overheating protection Phase lack protection Input over/low voltage protection |
||
| Working Condition (Temperature) |
-10℃~50℃ | Control mode | Panel control Remote control |
| Net weight | 25kg | Working mode | Constant Voltage(CV) Constant Current(CC) |
| Dimension(mm) | 520*395*165mm | Cooling way |
air cooling |


24V 200A alkaline water electrolysis power supply Optional Properties
- 12mbit Profibus DP concordance,opportunuty to connect single or in groups ProfiNet- 100 Mbit
ProfiNet
Concordance,opportunuty to connect single or in groups
Modbus-
Modbus communications over Ethernet or RS485
Ethernet Serial Communication
-Communication over RS 232 or RS485 on Mak Plus or a different protocol 100Mbit wired, 54 Mbit wireless
Analog Reference
- 0-10 V or 4-20 mA DC signal and the Current - Voltage control
PC Control
-Serial and Wireless Communication over RS 232/485 on MRS control software
PLC Control-
Ability to control motor system with two relay contact
Installation
| 1, Placing rectifier and keep the body stability; ensure good ventilation. |
| 2, Checking anodizing rectifier out cover if loosing. |
| 3, Connecting shell to ground to prevent static electricity. |
| 4, Conecting the AC input wire |
| 5, Connecting the DC output copper bars |
| 6, Connecting the rectifier remote control box,if local control ,skip this step |
| 7, Turn on air switch, then the fan starts to rotate and the power indicator light. |
| 8, Clockwise rotation adjustment button, voltmeter degree increases, working indicate light lighting. |
| 9, Adjust knob to maximum, then the voltmeter should indicate the rated voltage, current meter indicates the load volume accordingly. |
| 10, Disconnect the air switch, turn off the rectifier |
produce process :