HNS117 Remote Control 25mA Tunable 12V Microwave Sensor
12V microwave sensor Tunable white 0-10V dimming motion sensor HNS117 Quick Detail: 1. Tunable white and tri-level dimmming function by remote control setting (2 channels output), three color temperature options 2. small size motion sensor and daylight sensor Size: Features: 1. Operating voltage: 12V input 2. Small size: flexible to be integrated into any suitable fixtures. 3. Easy access by DIP switch shift between cool, white and warm. 4. CCT quick selection (DIP switch)
12V microwave sensor Tunable white 0-10V dimming motion sensor HNS117
Quick Detail:
1. Tunable white and tri-level dimmming function by remote control setting (2 channels output), three color temperature options
2. small size motion sensor and daylight sensor
Size:
![]() |
![]() |
Features:
| 1. | Operating voltage: | 12V input |
| 2. | Small size: | flexible to be integrated into any suitable fixtures. |
| 3. | Easy access by DIP switch | shift between cool, white and warm. |
| 4. | CCT quick selection (DIP switch) | DIP switch + IR Remote control 2 channels CCT setting |
| 5. | Mounting height: | 3〜6m |
| 6. | Output signal: | 0~10V, PWM signal can be customized, achieve color temperature adjustments. |
| 7. |
Source current / Sink current: |
Max. 20mA; 0-10V leads can not be short-circuit. |
Settings:
CCT Adjust
Cool: Long press to adjust the color temperature towards Cool , release to stop and lock down current color temperature.
Neutral: Press “Neutral” button, the color temperature will adjust to 50% cool + 50% warm.
Warm: Long press to adjust the color temperature towards Warm , release to stop and lock down current color temperature.
|
Ambient learn
Test mode Test mode defaulted settings--
In this mode, when used for on/off control, after motion detected, sensor enters into a cycle of 3s on and 2s off. |
![]() |
OCC OFF function
Press “OCC OFF” button, the motion sensor will be disabled.
Dim
Press “Dim” button to automatically dim up or down the light brighness during hold-time from 10% to 100%. Another press to lock it down when
desired brightness is achieved.
Reset function
Press “Reset” button, all sensor settings go back to factory default settings.
press “OCC ON” , “Reset” or “Ambient” to re-activate the motion sensor.
Factory default setting:
Sensitivity=100%
Daylight sensor=disable
Hold time=90s
Twilight time=5min
Twilight level=10%