Temperature Thermal Screening System Infrared Intelligent Thermal Imaging Security
Automatic Temperature Screening Infrared Intelligent Thermal Imaging Security The infrared thermal imaging temperature measurement technology of the CO-S3 intelligent rapid quarantine body temperature screening instrument adopts a high-resolution uncooled focal plane detector (384 X288), the temperature measurement accuracy is as high as±0.3°C, the image frame can reach 25Hz.It has reached the international advanced level in technology and is mature and reliable. Functions
Automatic Temperature Screening Infrared Intelligent Thermal Imaging Security
The infrared thermal imaging temperature measurement technology of the CO-S3 intelligent rapid quarantine body temperature screening instrument adopts a high-resolution uncooled focal plane detector (384 X288), the temperature measurement accuracy is as high as±0.3°C, the image frame can reach 25Hz.It has reached the international advanced level in technology and is mature and reliable.
Functions and Features
1. Use infrared non-contact detection of body temperature to reduce the risk of cross infection;
2. The detection time is less than 0.5 seconds;
3. High-sensitivity infrared thermal imaging monitoring and monitoring for 24 hours, and visualize the information;
4. High-precision non-contact temperature measurement,temperature accurancy is less than ±0.3℃;
5. Support abnormal temperature alarm function;
6. It can be applied to small scenes such as entrances, stores, etc., and large scenes with dense personnel.
Application scene:
Subway, airport, wharf, station, hospital, shopping mall and other places with large traffic.
| Specification | |
| Thermal imager | |
| Detector type | Uncooled Focal Plane Microbolometer |
| Resolution | 384×288 |
| Pixel pitch | 17μm |
| Wavelength range | 8~14μm |
| NETD | <40mK |
| Rate | 25Hz |
| IR Lens | 9.7mm/1.0 |
| IR FOV | 40°×30° |
| Visible Resolution | 1920×1080 |
| Visible FOV | 41°×22.2° |
| Blackbody | |
| Working temperature | 5℃~60℃ |
| Radiation surface | 80mm×80mm |
| Temperature resolution | 0.1℃ |
| Accuracy | ±0.2℃(35℃) |
| Stability | ±(0.1~0.2)℃/30min |