Machinery Electronic Products Machinery
China LCD Screen Thermoplastic Cut - Through Tester With Two Test Methods for sale
China LCD Screen Thermoplastic Cut - Through Tester With Two Test Methods for sale

LCD Screen Thermoplastic Cut - Through Tester With Two Test Methods

LCD Screen Thermoplastic Cut-Through Tester With Two Test Methods Product Overview The XHTC500 Thermoplastic Cut-Through Tester features an LCD screen and offers two distinct testing methods for comprehensive wire insulation analysis. Complies with NEMA and JIS standards Tests round enameled and filmed wires with conductor diameters from 0.1mm to 2.5mm Provides two testing methods: heated method and constant temperature method Automatically discharges load and alarms when

Place of Origin China
Packaging Details LCD Screen XHTC500 Thermoplastic Cut-Through Tester With Two Test Methods is packaged within wooden case.
Dimension of Heating Mould 100×100×70mm
Model Number ZL-2716
Supply Ability 60 Sets
Highest Test Temperature ≤500℃
Product Description
LCD Screen Thermoplastic Cut-Through Tester With Two Test Methods
Product Overview

The XHTC500 Thermoplastic Cut-Through Tester features an LCD screen and offers two distinct testing methods for comprehensive wire insulation analysis.

  • Complies with NEMA and JIS standards
  • Tests round enameled and filmed wires with conductor diameters from 0.1mm to 2.5mm
  • Provides two testing methods: heated method and constant temperature method
  • Automatically discharges load and alarms when sample is cut through
  • Displays test time and temperature upon completion
  • Features axial-flow fan for rapid cooling between tests
  • Automatically transfers testing data to computer systems
  • LCD screen displays testing steps and results clearly
Technical Specifications
Parameter Specification
Dimension of Heating Mould 100×100×70mm
Test Voltage Between Two Samples AC100±10V
Cutting-through Current 5±0.5mA
Short-Circuit Current Between Samples <50mA
Error Between Displayed Temperature and Sample's Temperature <2℃
Test or Preheating Time 1" ~ 99'59" predetermined
Included Angle Between Heating Mould's Two Winding Slots 90°
120 Seconds Error Allowance of Timing Device ±2s
Highest Test Temperature ≤500℃
Test Temperature of Constant Temperature Method Room temperature to 500℃ preset
Input Power Supply AC220V±10% 50Hz
Heating Power 750W
Dimension L×W×H 520×320×500 mm
Weight 35Kg
Interested in this product?
Contact us now for more details and a custom quote.