China CT LV Current Transformer Single - Phase Type Meet Higher Requirements for sale
China CT LV Current Transformer Single - Phase Type Meet Higher Requirements for sale

CT LV Current Transformer Single - Phase Type Meet Higher Requirements

LV Current Transformer 0.72kV Indoor Single-Phase Type Meet Higher Requirements 1. Introduction BH-0.66Ⅲ Current Transformer mainly used in three-phase busbar vertical circumstance, it belongs to enlarged type CT, have more higher accuracy, can meet higher requirements of large impedance and electrical energy metering .Jack screw fixed the busbar, it is convenient to install. P1,P2 Primary terminals,S1,S2 secondary terminals. P1&S1 same as P2,S2(Subtractive polarity) 2.

Place of Origin ShenZhen
Paking 15pcs/Carton =460*270*175mm
Packaging Details Carton packing for one sets, one set including three piece with Components
Installation Site Indoor
Model Number BH-0.66Ⅲ
Supply Ability 36,000,00pcs per year
Product Description

 
LV Current Transformer 0.72kV Indoor Single-Phase Type Meet Higher Requirements

 

1. Introduction

 

BH-0.66Ⅲ Current Transformer mainly used in three-phase busbar vertical circumstance, it belongs to enlarged type CT, have more higher accuracy, can meet higher requirements of large impedance and electrical energy metering .Jack screw fixed the busbar, it is convenient to install.

P1,P2 Primary terminals,S1,S2 secondary terminals.

P1&S1 same as P2,S2(Subtractive polarity)

 

2. Specification

 

Model No. Outline Dimension Penetrate Dimension Installation Dimension Installation
W H D A E Φ M
20II 72 76 36 11 21 21 40 A,J
30 II 73 98 50 12 32 26   A,J
50 II 75 120 56 16 52 /   J
60 II 100 145 55 32 62 /   J
80 II 100 164 55 32 82 /   J
100 II 100 196 55 32 102 /   J
120 II 125 221 55 52 122 /   J
130 II 125 221 55 56 132 /   J

 

3.Technical Parameter:

  1. Rated primary current: 5-3000A; Rated secondary current: 5A, 1A
  2. Rated voltage: AC 660V
  3. Rated frequency: 50-60Hz
  4. Ambient temperature: -30℃- +50℃
  5. Altitude: ≤3000m
  6. Power frequency withstand voltage: 3000V/1min, 50Hz(between cover and secondary winding).

 

4.Technical Parameter:

 

Specification 20III 30III 50III 60III 80III 100III 120111 130111
Spec of busbar 20X10 1 30X10 1 50X10 1 60X10 1~2 80X10 1~2 100X10 1~2 120X10 1~3 130X10 1~3
Accuracy Class 0.5 1 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.5
Rated Current Rated Burden (VA)
75/5   2.5                            
100/5   2.5   2.5                        
150/5 2.5     2.5                        
200/5 5     5                        
250/5       5                        
300/5     5 10                        
400/5     10 10 10 10 10 10                
500/5     10 10 10 10 10 10                
600/5     10 10 10 10 10 10                
750/5         10 10 10 10 10 10            
800/5         10 10 10   10 10 10 10 10      
1000/5         15   15   15   15   15      
1200/5             20   20   20   20   20  
2000/5             20   20   20   20   20  
2500/5             40   40   40   40   40  
3000/5                 40   40   40   40  
4000/5                 40   40   40   40  
5000/5                     40   40   40  
                      40   40   40  
150/1 2.5     2.5   2.5                    
200/1 5     5   5                    
250/1       5   5   5                
300/1       5   5   5                
400/1       10   10   10   10            
500/1       10   10   10   10   10        
600/1       10   10   10   10   10   10    
750/1           10   10   10   10   10    
800/1           10   10   10   10   10    
1000/1           10   10   10   10   10    
1200/1             20   20   20   20   20  
1500/1             20   20   20   20   20  
2000/1             20   20   20   20   20  
2500/1                     20   20   20  
3000/1                     20   20   20  
4000/1                     20   20   20  
5000/1                     20   20   20  

 
Dimension:
 

Interested in this product?