China Enclosed Support Construction Bushing Type Current Transformer Epoxy Resin for sale
China Enclosed Support Construction Bushing Type Current Transformer Epoxy Resin for sale

Enclosed Support Construction Bushing Type Current Transformer Epoxy Resin

Enclosed Support Construction MV Current Transformer 12kv Epoxy Resin 1. Product Introduction: LZZBJ9-12/150b/4 current transformer, epoxy resin casting insulation and fully enclosed support construction, encloses the primary & secondary windings and annular core in the epoxy resin casting body. The product has the feature of light weight, omnidirectional installation, withstanding nastiness and dampness. It is widely used for measuring current, electric energy and protective

Place of Origin Shenzhen
Packaging Details Plywood
Standard IEC60044-1(IEC61869-1&2)​
Material Epoxy Resin
Model Number LZZBJ9-12/185h/2
Supply Ability 36,000,00pcs per year
Product Description

 

Enclosed Support Construction MV Current Transformer 12kv Epoxy Resin

 

 

 

1. Product Introduction:

 

LZZBJ9-12/150b/4 current transformer, epoxy resin casting insulation and fully enclosed support construction, encloses the primary & secondary windings and annular core in the epoxy resin casting body. The product has the feature of light weight, omnidirectional installation, withstanding nastiness and dampness. It is widely used for measuring current, electric energy and protective relaying in the electrical system with the rated frequency 50Hz or 60Hz and highest voltage for equipment 12kV.

 

 

2. Technical Data:

 

 

Main technical parameter

 

  1. Rated insulation level: 12/28/75kV

  2. Rated frequency: 50hz/60hz

  3. Installation Site:Indoor

  4. Standards: IEC60044-1.2003

Standards: IEC60044-1.2003

 

 

 
3. Specification:
 
 
 
Rated current ratio (A) Accuracy classes combination

Rated output

(VA)

FS ALF Rated short-time thermal current (kA/S) Rated dynamic current ( kA)
Measuring Protective
0.2(S) 0.5 10P
10-200/5

0.2(S)/ 0.2(S)

0.2(S)/0.5

0.2(S)/10P

0.5/10P

0.2(S)/0.5/10P

0.2/0.5/10P

10

15

15

15

20

5

(10)

10

15

20

100I1n 250I1n
300/5 31.5 80
400/5 31.5 80
500/5 40 100
600/5 50 125
800/5 63 125
1000/5 80 160
1200~1500/5 80 160
1500~2000/5 100 160
2000~2500/5 100 160
 
 
Rated current ratio (A) Accuracy classes combination

Rated output

(VA)

FS ALF Rated short-time thermal current (kA/S) Rated dynamic current ( kA)
Measuring Protective
0.2(S) 0.5 10P
10-200/5

0.2(S)/ 0.2(S) /10P/10P

0.5/10P /10P

 

0.2(S)/ 0.2(S) /10P/10P

0.2/0.5/10P/10P

10

15

15

15

20

5

(10)

10

15

20

100I1n 250I1n
300/5 31.5 80
400/5 31.5 80
500/5 40 100
600/5 50 125
800/5 63 125
1000/5 80 160
1200~1500/5 80 160
1500~2000/5 100 160
2000~2500/5 100 160
 
 
 
 
4. Outline Drawing:
 
 
 
 
 
 
 
5.Photos:
 
 
 
 
 
Interested in this product?