China Realtime Clock Portable Reference Standard Meter Class 0.3 Low Voltage Circuit for sale
China Realtime Clock Portable Reference Standard Meter Class 0.3 Low Voltage Circuit for sale

Realtime Clock Portable Reference Standard Meter Class 0.3 Low Voltage Circuit

Single Phase Portable Reference Standard Meter class 0.3 on-site tester KE7201 Single Phase Portable Reference Standard Meter KE7201 is handheld instrument that is perfect for on-site electrical testing, like voltage measurement, current measurement, power measurement etc. very light and compact. Besides, it is able to measure the error of single phase energy meter under class 0.5. Main functions: Energy accumulating test (Dial test) Test ratio of current transformer in low

Voltage range 20V - 420V
Place of Origin China
Warranty 12 months
Phase Single
Packaging Details Carton
Material Plastic & rubber
Product Description

Single Phase Portable Reference Standard Meter class 0.3 on-site tester

KE7201 Single Phase Portable Reference Standard Meter

 

KE7201 is handheld instrument that is perfect for on-site electrical testing, like voltage measurement, current measurement, power measurement etc. very light and compact. Besides, it is able to measure the error of single phase energy meter under class 0.5.

Main functions:

  1. Energy accumulating test (Dial test)
  2. Test ratio of current transformer in low voltage circuit
  3. Input current through clamp CT
  4. Display vector diagram
  5. Display waveform of voltage and current
  6. Analyze and display 2nd – 41st harmonic of voltage and current at real time
  7. Realtime clock, accurate record testing time
  8. Store, browse and transfer the test record
  9. Real-time measured data by PC, and download calibration parameter
  10. Two kinds of power supply way: external AC power and voltage test lead power
  11. Alarm when the tested voltage and current is over the test
    range

 

Technical index:

  KE7201
Voltage measurement
Voltage range 20V – 420V
Accuracy ±0.1%
Harmonics 2nd- 41st
Current measurement ( clamp input)
Current range 5A, 100A, 500A, 1000A
Accuracy ±0.3% (5A, 100A, ±0.5% (others)
Harmonics 2nd- 41st
Power measurement
Active power ±0.3% (5A, 100A), ±0.5% (others)
Reactive power ±0.5%
Energy measurement
Active energy ±0.3% (5A,100A), ±0.5% (others)
Reactive energy ±0.5%
Phase measurement
Phase range 0 -- 360°
Accuracy ±0.1°
Frequency measurement
Frequency range 45Hz – 65Hz
Accuracy ±0.05Hz
Pulse output
Low frequency output(CL) 1000imp / kWh
Pulse input
Input channel 1
Input frequency Max.100Hz
Others
Dimensions 190mm×140mm×50mm
Weight 1.3kg
Power supply

external power supply (45V –420V)

powered by the tested terminal

 

 

Interested in this product?